Supermelt - SI Power System Panel


  • Melt rate and Power Consumption with hot lining and dense and clean scrape.

  • KVA (input) is the Power requirement for Furnace alone.

  • Voltage (input) 3 Phase, 50 Hz.

  • Power Factor (Line) always more than 0.95.

  • For Melt rate of other metals multiply rate of Steel by, 1 for Aluminum, 1.6 for Copper, 1.8 for Bronze.


SECONDARY ISOLATED SUPERMELT-SI POWER SYSTEM TECHNICAL SPECIFICATIONS PERFORMANCE DETAILS FOR MELTING OF FERROUS ALLOYS

KW CAPACITY SIZE FREQ HZ INPUT MELT RATE
(KG /HOUR)
CONSUMPTION
(KWH/TON)
CRUCIBLE CAPACITY KG.
    KVA Volts Steel C.I Steel C.I 1 2 3
        1650°C 1480°C 1650°C 1480°C Kg. Kg. Kg.
75 3000/1000 90 415 100 110 870 775 25 50 100
125 3000/1000 150 415 180 195 800 725 50 100 150
150 3000/1000 180 415 225 245 775 700 100 150 200
175 3000/1000 210 415 260 285 770 690 150 200 250
250 1000/500 290 415/550 430 470 660 600 300 500 -
350 1000/500 420 415/550 620 675 640 580 500 750 1000
450 1000/500 515 415/550 815 895 620 560 500 750 1000
550 1000/500 635 415/550 1010 1125 610 550 750 1000 1500


View Complete Details