The Thermic Fluid Heater that we offer our clients is sourced from trusted vendors. Our fuel fired thermic fluid heater is easy and safe to handle, as it is incorporated with various safety measure equipment. They need low maintenance and provide long lasting brilliant performance even in tough weather conditions. Salient Features Fully automatic Easy operation & fail proof system Outside the purview of IBR 100% depreciation in the first year High efficiency Technical Specifications Capacities from 50, 000 Kcals/hr to 10, 00, 000 Kcals/hr Maximum operating temperature of 300 o C Over all efficiency of 88%± 1% on N.C.V Four heat transfers Efficient combustion, forced circulation, liberal heat transfer areas & large furnace volume Specifications Details Unit NT-50 NT-100 NT-200 NT-300 NT-400 NT-600 NT-1000 Operating Parameters Capacity KCals/Hr. 50000 100000 200000 300000 400000 600000 1000000 Max. Operating Temp. (At the outlet of the unit) 0 C 300 300 300 300 300 300 300 Fuel Oil Consumption At full load LDO FO Kgs/Hr Kgs/Hr. 5.4 10.8 21.5 22.6 32.4 33.9 42.9 45 64.3 67.5 107.2 112.5 Efficiency (GCV) % 86+/-1 86+/-1 86+/-1 86+/-1 86+/-1 86+/-1 86+/-1 Burner Contro -------------------------ON-OFF------------------ Electric Supply AC-3 Phase - 415V +/- 6% 50 Hz 4 Wire Thermic Fluid Pump Motor (HP) 3 5 7.5 10 10 20 25 Blower Motor (HP) 1 1.5 2 2 3 5 10 Fuel Oil Preheater (For F.O. Fired Unit Only) KW - - 3 4.5 4.5 6 9 Total Elec. Load For LDO Fired Units For FO Fired Units HP HP + KW 4 6.5 9.5 9.5+3 12 12+4.5 13 13+4.5 25 25+6 35 35+9 Length (Mts) 2 3 4 4 4 4 4 Width (Mts) 2 3 4 4 4 5 5 Clear Height (Mts) 2.5 2.5 4 5 5 5 6 Fuel Gas Outlet (MM) 250 250 250 300 30 400 500 Cross Dry Weight (Kgs) 1000 1350 1750 2400 2900 3500 5250 PARAMETERS UNIT NTC : 200 NTC : 300 NTC : 400 NTC : 600 NTC : 1000 - - Heat Output Kcal/hr 2, 00, 000 3, 00, 000 4, 00, 000 6, 00, 000 10, 00, 000 - - Outlet temperature (max) 0 C 300 300 300 300 300 - - Temp rise ( T) in the heater 0 C 25 25 25 25 25 - - Pressure at heater outlet Kg/cm2 2.2 2.2 2.5 2.5 2.5 - - Flue gas duct diameter mm 250 300 300 350 450 - - Inlet / Outlet connection of heater mm 50 50 65 65 100 - - FUEL CONSUMPTION Coal Kgs/hr 64 96 128 192 320 - - Wood Kgs/hr 87 130 174 260 435 - - ELECTRICAL LOAD Thermic Fluid Pump Motor Kw 5.5 5.5 7.5 11.0 15 - - I.D. fan motor + F.D. fan motor Kw 1.5+0.375 2.2+0.75 2.2+0.75 3.7+1.5 5+2.2 - - Total Connected Load Kw 7.375 8.45 10.45 16.2 22.2 - - Designs and Specifications subject to changes due to constant research and development The efficiency is guaranteed on the test bay with commercially clean internal and external heat transfer surfaces