Our Products
D.C. Systems comprising of Battery and Battery Chargers upto 500KW Float & boost or float cum boost, constant voltage & constant current, thyristor controlled, upto 500 kW rating, suitable for lead acid, SMF, or Ni-Cd batteries ranging from 20 AH to 5000 AH and 12 V to 220 V or any custom made range. Resistive Load Banks for Battery Discharging Rectifiers (500 kW).
TYPE12V, 24V, 48V, 110V, 220V or any custom made up to 500KW suitable for Lead Acid Flooded, SMF (VRLA), Ni-Cd Batteries and LithiumIon Batteries
APPLICATION440V AC, 220V DC upto 5000A, Customize as per requirement
SMPS modules: for Battery Charging & supplying load DC-DC Converter Modules: For Supplying different DC voltages load Inverter Modules: with optional Static bypass switch for supplying single phase or Three phase AC load. Control & Monitoring Unit: for Power Supply Management, Battery Management, Remote Monitoring & Control Through Modems/ Industrial Ethernet. Racks: for mounting Power Supply Modules, Connection of input, Output & Load Distribution.
ADVANTAGESMass-Tech in association with CONVERTRONIC, Germany introduces MU1000, a control & monitoring unit for DC systems. MU1000 offers complete monitoring of a DC system with unique features like battery management with automatic Battery test, Event history, Remote transmission of system data via telephone/Ethernet.
The MU1000C is specially designed for harsh industrial environment. The MU1000C is compact, user friendly, easy to operate from front panel keypads with LCD display 2x16 matrix clear text indication with illumination.
The MU1000 can be used in the new DC systems & can also be retrofitted in the existing DC system of any make. DC systems with MU1000 shall have following unique advantages.
ADVANTAGESBatteries form the backbone in the operation of a plant performance and dictates the dependability of DC system. In plant, normally batteries of different type viz Lead Acid, SMF or Ni-Cd and of varying AH capacities are used for following applications.
APPLICATION AREASAvailability of DC Supply incase of Power failure or emergency, depends on battery condition/State of Charge. A single weak cell in a battery bank, can lead to failure of total systems resulting in major shutdown. Normally it is very difficult to determine the health/State of Charge of individual cell in a battery bank and also it is not possible with the existing equipment to charge such cells without disturbing / disconnecting the system.
MULTI-APPLICATIONCathodic Protection (CP) is a method of corrosion control that can be applied to buried and submerged metallic structures. In conjunction with coating, a properly designed and maintained CP will ensure a 100% efficient corrosion Protection System.
The Principle of CP is to prevent anodic sites occurring on the structure under protection by allowing anodic reactions to occur on specially designed and installed anodes.
The PR is designed to operate is constant current mode and the current is adjustable manually.
The PR has various protections like surge protection, fast acting semiconductor fuses, DC overload, DC over voltage, short circuit protection and AC under voltage and also fast acting current limiting which protects the PR from supplying current higher than the set value.