We are the renowned Importer and Supplier of GK600 Series AC Motor Drive in the industry. The GK600 Series AC Motor Drive functions with the help of an advanced sensorless vector control technology that features a sturdy and precise sensorless vector control along with different V/f curves programmable. GK600 Series AC Motor Drive is widely used in varied industries and is available at competitive prices. The GK600 Series AC Motor Drive is highly in demand due to its favorable performance-price ratio, easy operation and low maintenance. Attributes Easy to operate Reliable Durable Affordable Specifications Model Power Rating (KW) Rated Output Current (A) External Dimensions   (H*W*D) (mm) Package Dimensions     (H*W*D) (mm) Vol.(CBM) Gross Weight(kg.) 3AC 380V/400V/415V/440V/460V/480V -10%~10% GK600-4T1.5G/2.2LB 1.5/2.2 3.8/5.5 245*120*169 307*188*269 0.02 3.7 GK600-4T2.2G/3.7LB 2.2/3.7 5.5/9 245*120*169 307*188*269 0.02 3.7 GK600-4T3.7G/5.5LB 3.7/5.5 09/13/13 245*120*169 307*188*269 0.02 3.7 GK600-4T5.5G/7.5LB 5.5/7.5 13/17 280*145*179 352*226*278 0.02 4.8 GK600-4T7.5G/11LB 7.5/11 17/24 280*145*179 352*226*278 0.02 4.8 GK600-4T11G/15LB  11/15 24/30 365*190*187 443*284*301 0.04 6.7 GK600-4T15G/18.5LB 15/18.5 30/39 365*190*187 443*284*301 0.04 6.7 GK600-4T18.5G/22L(B) 18.5/22 39/45 475*270*220 572*367*316 0.07 18 GK600-4T22G/30L(B) 22/30 45/60 475*270*220 572*367*316 0.07 18 GK600-4T30G/37L(B) 30/37 60/75 475*270*220 572*367*316 0.07 18 GK600-4T37G/45L(B) 37/45 75/91 568*320*239 660*443*450 0.13 33.5 GK600-4T45G/55L(B) 45/55 91/112 568*320*239 660*443*450 0.13 33.5 GK600-4T55G/75L 55/75 112/150 670*385*255 740*470*435 0.15 46 GK600-4T75G/90L 75/90 150/176 670*385*255 740*470*435 0.15 46 GK600-4T90G/110L 90/110 176/210 785*395*285 910*495*460 0.15 61.5 GK600-4T110G/132L 110/132 210/253 785*395*285 910*495*460 0.31 83 GK600-4T132G/160L 132/160 253/310 900*440*350 1025*565*530 0.31 83 GK600-4T160G/185L 160/185 310/350 900*440*350 1025*565*530 0.31 83 GK600-4T185G/200L 185/200 350/380 900*440*350 1025*565*530 0.31 83 GK600-4T200G/220L 200/220 380/430 1040*650*370 1162*768*576 0.51 132 GK600-4T220G/250L 220/250 430/470 1040*650*370 1162*768*576 0.51 132 GK600-4T250G/280L 250/280 470/520 1040*650*370 1162*768*576 0.51 132 GK600-4T280G/315L 280/315 520/590 1040*650*370 1420*940*500 0.67 132 GK600-4T315G/355L 315/355 590/650 1300*800*400 1420*940*500 0.67 174 GK600-4T355G/400L 355/400 650/725 1300*800*400 1420*940*500 0.67 174 GK600-4T400G/450L 400/450 725/820 1300*800*400 1420*940*500 0.67 174 3AC 208V/220V/230V 50/60Hz -10%~10% GK600-2T2.2GB 2.2 10 245*120*169 307*188*269 0.02 3.7 GK600-2T3.7GB 3.7 16.5 280*145*179 352*226*278 0.02 4.8 GK600-2T5.5GB 5.5 24 365*190*187 443*284*301 0.04 6.7 GK600-2T7.5GB 7.5 30 365*190*187 443*284*301 0.04 6.7 GK600-2T11G(B) 11 45 475*270*220 572*367*316 0.07 18 GK600-2T15G(B) 15 60 475*270*220 572*367*316 0.07 18 GK600-2T18.5G(B) 18.5 73 568*320*239 660*443*450 0.13 33.5 GK600-2T22G(B) 22 96 568*320*239 660*443*450 0.13 33.5 GK600-2T30G 30 112 670*385*255 740*470*435 0.15 46 GK600-2T37G 37 144 670*385*255 740*470*435 0.15 46 GK600-2T45G 45 176 785*395*285 910*495*460 0.15 61.5 GK600-2T55G 55 210 785*395*285 910*495*460 0.15 61.5 GK600-2T75G 75 288 900*440*350 1025*565*530 0.31 83 GK600-2T90G 90 350 900*440*350 1025*565*530 0.31 83 GK600-2T110G 110 415 1040*650*370 1162*768*576 0.51 132 Note The letter "(B)" in the model name means inbuilt brake unit is optional. Factory default - No inbuilt brake unit in these models with (B) in this quotation. Technical Features Power input Rated input voltage 3-phase AC208V/AC220V/AC230V/AC240V/AC380V/AC400V/AC415V/AC440V/AC460V/AC480V Rated input current See Section 2.3 in user manual Frequency 50Hz/60Hz, tolerance ±5% Allowable range of voltage Continuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V; Voltage out-of-balance rate Power output Standard applicable motor (kW) See Section 2.3 in user manual Rated current (A) See Section 2.3 in user manual Output voltage (V) 3-phase: 0~ rated input voltage, error Output frequency (Hz) 0.00~ 600.00Hz; unit: 0.01Hz Overload capacity 150% - 1min; 180% - 10s; 200% - 0.5s Control characteristics V/f patterns V/f control Sensor-less vector control 1 Sensor-less vector control 2 Range of speed regulation 1:100 ( V/f control, sensor-less vector control 1) 1:200 (sensor-less vector control 2) Speed accuracy ±0.5% (V/f control) ±0.2% (sensor-less vector control 1 & 2) Speed fluctuation ±0.3% (sensor-less vector control 1 & 2) Torque response Starting torque 0.5Hz: 180% (V/f control, sensor-less vector control 1) 0.25Hz: 180% (sensor-less vector control 2) Basic functions Start frequency 0.00~ 600.00Hz Accel/Decel time 0.00~60000s Carrier frequency 0.7kHz~16kHz Frequency setting sources Digital setting + keypad âˆÂ§/ Digital setting + terminal UP/DOWN Communication Analog setting (AI1/AI2/EAI) Terminal pulse setting Motor started methods Started from starting frequency DC braking and then started Speed search started Motor stopped methods Ramp to stop Coast to stop Ramp stop + DC brake Dynamic braking capacity Brake unit action voltage: 650V~750V; service time: 0.0~100.0s; brake units for GK600-4T45G/55L and below are built in or can be built in. See table 2-1 DC braking capacity DC braking start frequency : 0.00~600.00Hz DC braking current : 0.0~100.0% DC braking time : 0.0~30.00s Input terminals 6 digital inputs, one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input. Digital inputs can be extended to 7 2 analog inputs, one of which is voltage/current programmable, and the other supports voltage only. Analog inputs can be extended to 3, and the extended one is voltage/current programmable Output terminals 1 high-speed pulse output, 0~50kHz square wave signal output; can output signals such as command frequency, or output frequency, etc. 1 digital output 1 relay output (can be extended to 2) 1 analog output (can be extended to 2), voltage/current output programmable; can output signals such as setting frequency, or output frequency, etc Featured functions Parameter copy, parameter backup, common DC bus, free switchover between two motors’ parameters, flexible parameter displayed & hidden, various master & auxiliary command and switchover, speed search started, a variety of Accel/Decel curves optional, automatic correction of analog, contracting brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), wobble frequency control, fixed length control, count function, three faults recorded, over excitation brake, over voltage stall protection, under voltage stall protection, restart upon power loss, skip frequency, frequency binding, four kinds of Accel/Decel time, motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, parameter identification, field-weakening control, high-precision torque restraint, V/f separated control Protection functions Refer to Chapter 7- Troubleshooting Environment Place of operation Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop or salt, etc. Altitude 0~2000m De-rate 1% for every 100m when the altitude is above 1000 meters Ambient temperature  -10 o C~50 o C Relative humidity 0~95%, no condensation Vibration Less than 5.9m/s2 (0.6g) Storage temperature -40 o C~+70 o C Others Efficiency at rated Amps Rated power 7.5kW and below: â‰Â¥93% 11~ 45kW: â‰Â¥ 95%     55kW and above: â‰Â¥98% Installation Wall-mounted IP grade IP20 Cooling method  Fan cooled