We offer anti radiation cables. Technical data* polyetheretherketone (peek) wires insulated with unfilled semi-crystalline polymer films for high temperature resistance & demanding applications nominal voltage uou 300500v test voltage 6000v op. Temperature -60° to 260°c max. Temperature +300°c short time insulation resistance 4.1 x10^16 ùcm min. Bending radius 7x cable diatensile strength @ break 120mpa(23°c) elongation @ break >150%(23°c)tear strength >150%(23°c)tolerance on od + 0, 10 mm 2.5mm²applications ‘udeywirecab’ peek insulated wires are special cores for use in very high temperature areas coupled with requirement of high radiation resistace, mainly in medical industry, aviation, shipping & nuclear technologiespeek is high performance semi-crystalline thermoplastic is very tough and isof withstanding high temperatures along with exceptional resistance to uv & energy radiation (gamma & x-ray)peek wires can be easily strengthened withptfe fillers alongelectrical properties-solid insulation copper conductor dimensions high temperature resistant to good resistance to hydrolsis high abrasion resistace radiation over 1000mrad execellent resistance to uv & high energy radiation (gamma & x-ray) conductor + 0, 16 mm > 2.5mm² (apx.) (n°x ømm) (mm) (mm) (mm) (ohmkm) amperey(mm²) conductor insulator (tape wrapped & fused) solid peek tensile strength @ break 120mpa(23°c) elongation @ break >150%(23°c) tear strength >150%(23°c) low thermal expansion coefficient high thermal load carrying capacity high creep resistance low flammability & low smoke secretion during combustion. 20 7 x 0, 32 1, 00 0, 20 1, 40 34, 30 11 0, 60 6 1 x 3, 86 3, 86 0, 20 4, 30 1, 10 90 11, 70 20 1 x 0, 81 0, 81 0, 20 1, 20 35, 00 11 0, 50 (i) max upto 150°c awg no. Resistance diameter max@20°c insulation thickness outer cable ø cross composition section 18 1 x 0, 96 0, 96 0, 20 1, 40 23, 10 15 0, 75 18 7 x 0, 40 1, 20 0, 20 1, 60 24, 00 16 0, 90 16 1 x 1, 29 1, 29 0, 20 1, 70 14, 00 20 1, 30 16 19 x 0, 29 1, 45 0, 20 1, 85 16, 20 19 1, 25 15 1 x 1, 38 1, 38 0, 20 1, 80 12, 00 23 1, 50 15 19 x 0, 32 1, 60 0, 20 2, 00 11, 01 25 1, 50 14 1 x 1, 63 1, 63 0, 20 2, 10 9, 90 28 2, 00 13 1 x 1, 83 1, 83 0, 20 2, 30 7, 41 33 2, 50 12 1 x 2, 04 2, 04 0, 20 2, 45 5, 10 40 3, 30 10 1 x 2, 56 2, 56 0, 20 3, 00 3, 90 51 5, 00 y single core cables upto ambient temp. Of 150°c, installed in open air with a space of min. 1x diameter to wall. *above details are based on characteristic data of material used as per raw material mfr. Specification this document is an exclusive ‘udey wires & cables’ property. Current laws defend this property and forbid it’s improper use .