Our Products
As per as per ASTM D - 638 / ASTM D 882
Model: AE-TT-C-1LC-500
Reference Standards: ASTM, ISO, IS
Specifications :
Load Capacity: 500 Kg with 10 gram resolution (others optional).
Load cell: 1 No (Others optional).
Cross Travel: 1000 mm with 0.01 mm resolution.
Test Speed: 10 500 mm/Minute (others optional).
Reports: Graphical + Data through software
Units: KG; Newton; Pound; cm; mm; inch.
Data Merging Facility: Available
Reports Contain: Peak load, Break load, Yield Load, Elongation @Peak load, Elongation@break load, Elongation @yield load, Tensile Strength @peak load, Tensile strength @breakload, % elongation @peak load, % elongation @break load, % elongation @yield load, Youngsmodulus, Load Vs Elongation graph.
Accessories: Pneumatic Grip 1 Pair
Supply: 230 VAC/50 Hz
Paint: Powder coated
Special Features :
Table Top Model.
Model: AE-W20-L300-1
Mechanical-electrical integration of control system.
Sealing Area 20 X 300 mm Flat ----- Single Part (others optional)
Seal temperature: Room temperature - +300c
Accuracy: 0.2c.
Heating system for both jaws.
Pneumatic System for jaw pressure
Pressure: 0.05Mpa--0.7Mpa
Dwell time: 0.01s- 9.99 secs
P.I.D. temperature controller 02 Nos.
Power: 1.5 Kw
Supply: 230 VAC/50 Hz
COMPUTERISED HUMIDITY CHAMBER
As per ASTM, ISO & IS standards
To simulate the various conditions of Temperature + RH.
Easy to run the chamber.
Operations from both sides, through controller as well as through computer.
Graphical presentation on PC.
Report generation in the form of Data + Graphicalv
Temperature 10 C to 85 C.
Temperature resolution 0.1 C.
Accuracy +/- 0.2 C.
Humidity 0 % to 100 %Rh.
Resolution 0.1 %Rh.
Accuracy +/- 2 %Rh.
Supply 230 VAC 10 VAC/ 50 Hz.
Paint Powder coated.
For making V notches in Izod/Charpy samples as per ASTM D256
Reference Standards: ASTM, ISO, IS
Models: AE-MNC-A
System Status: Analog
Range: 0 25.00 mm
Resolution: 0.01 mm
Cutting Angle of Tool: 45C
Samples Notching: At a time 5 samples, having 3.5 mm thickness of each
Supply: 230 VAC/50 Hz
Power: 250 Watts
Paint: Powder coated
Use : For sample cutting purpose.
Capacity : 5 ton (others optional)
Operation : Manual.
Horizontal day light : 12 inch.
Cross travel : 4 inch.
Paint : Powder coated.
To check the impact effect on the seat surface of the plastic molded chairs.
Specifications :
It is designed to carry a load of 140 kg. The apparatusconsists of a motor fitted with a Variable pitch pulleyhoused in a cabinet.
The vibrations are imparted by means of off-balancemasses rotating on a shaft of a Vibrator clamped tothe underside of the table top.
The table top is 50cm x 50cm. and has stops alongits edges to prevent moulds from Walking off the tableduring vibration.
A cross arm adjustable on a vertical rod at the centerof The table is provided to hold the moulds while operatingthe table.
The variable pitch pulley arrangement permits thefrequency to be varied sleeplessly Between a maximumof 1400 vibrations per minute.
Digital Frequency Indicator + controller with resolutionof 1 Hz
Digital indicator for amplitude measurement.
Electric Supply of 440 volts, 3 phase, 50 Hz
Vibrating Tables of table top size 50cm x 50cm aswell as 1000cm x 100cm are also available.(OR as per customers choice.)
As per IS 9000, JSS 55555, JSS 50101, MIL STD 750, 810, 883, IEC - 60068
The extreme simulation of temperature is conducted in two zones of hot and cold that can be controlled independently and an optional third zone. The single basket product carrier moves vertically, from one zone to the other, subjecting the product to dramatic changes in temperature thus creating a temperature shock thereby detecting specimen flaws.
Features :
Vertical movement of basket with separate hot and cold temperature zones.
The Basket transition is done through a Robust Electro-pneumatic Method.
Mono-block design with integrated.
Non-CFC cascade refrigeration system.
DIGITAL Controller.
Castor wheels for easy movement of the chamber.
Models Available :
Models | AE-25-B2V | AE-64-B2V | AE-120-B2V |
Basket/Test Space(W X D x H) | 25L250 x 250 x 400 (MM) | 64L400 x 400 x 400 (MM) | 121L550 x 550 x 400 (MM) |
Zone1 Temperature | 60C to 200C | ||
Zone2 Temperature | 0C to -75C | ||
Basket Transition Time | 5 to 30 seconds | ||
Basket Movement | VERTICAL |
Complies GLP/GMP.
Dye cast aluminum design for long term stability & accurate results.
Various weighing units like gm, mg, ct, oz, dwt, mon, GN.
Standard RS-232 C interface.
Easy to read large backlit LCD display with A. E. P. (Advance Eye Protection)(New).
Hanger for below balance weighing (Optional).
Fully automatic internal calibration with built in weight (Optional).
User selectable stability & filter level specious draft shield interior.
Improved repeatability for better.
Model | AE 65 | AE 125 | AE 225 | AE 600 | AE 2200 |
Capacity | 60gm | 120gm | 220gm | 500gm | 2000gm |
Readability | 0.1mg | 0.1mg | 0.1mg | 0.01mg | 0.01mg |
Pan size | 90mm ø | 90mm ø | 90mm ø | 90mm ø | 90mm ø |
Temperature range: 50 - 160 C
Minimum sample weight: 0.5 g
Maximum sample weight: 35 g
Readability moisture content: 0.01%
Readability: 1 mg
Temperature adjustment: Intervals of 1 C
Results: Moisture and dry content in %, dry content in g, ATRO Dry, ATRO Wet
Drying programs: 1 (standard)
Switch-off criteria Fully automatic, manual, time controlled
Repeatability (s) (2 g sample): 0.15 %
Repeatability (s) (10 g sample): 0.05 %
Interface: RS232C
Display: LCD back-lit, blue on white background
Printer: External
Models: AE-MF-S
Working Size: 4 X 4 X 9
Temperature Controlling System: Microcontroller based PID
Temperature Range: Ambient 1100C ***
Temperature Resolution: 1C
Accuracy: +/- 0.25% of the range in throughout the chamber
Safety Thermal Fuse Protection: Optional***
Safety MCB Protection: Available ***
Smoke Ventilation: Provided on backside
Accessories: Crucible; Long Twister
Supply: 230 VAC/50 Hz
Power: 1.5 KW