Our Products
Our Complete range of products are Rib Lath, Hy-Rib Lath, Coil Lath, Corner Mesh and System Components Stud.
Details
| Ref | Dimension | Standard thickness (mm) Upto | Standard Length (mm) | Material | Bundle | ||
| A | B | C | |||||
| 48SD | 48 | 34 | 32 | 0.45 to 0.80 | 3000 | G.I. Steel | 12 |
| 50SD | 50 | 34 | 32 | 0.45 to 1.20 | 3000 | G.I. Steel | 12 |
| 60SD | 60 | 34 | 32 | 0.45 to 0.80 | 3000 | G.I.Steel | 12 |
| 63SD | 63 | 34 | 32 | 0.45 to 0.80 | 3000 | G.I. Steel | 12 |
| 70 SD | 70 | 34 | 32 | 0.45 to 1.20 | 3000 | G.I. Steel | 12 |
| 73 SD | 73 | 34 | 32 | 0.45 to 1.20 | 3000 | G.I. Steel | 12 |
| 90 SD | 90 | 34 | 32 | 0.45 to 0.80 | 3000 | G.I. Steel | 12 |
| 92 SD | 92 | 34 | 32 | 0.45 to 1.20 | 3000 | G.I. Steel | 12 |
| 98 SD | 98 | 34 | 32 | 0.45 to 1.20 | 3000 | G.I. Steel | 12 |
| 148 SD | 148 | 34 | 32 | 0.45 to 1.20 | 3000 | G.I. Steel | 8 |
Details
Rib Lath is extensively used for plastering background for suspended ceiling, partitions and walls. For walls and partitions purpose it is recommended to use RL 1.48 kg/m2 and for ceiling purpose 1.85 kg/m2 or in some cases 2.22 kg/m2.
| Reference | Weight (Kg/m2) | Height of RIB (mm) | Width / Length (mm) | Material |
|---|---|---|---|---|
| RLS | 1.48 | 10 | 600/2500 | Galvinased steel |
| RLM | 1.84 | 10 | 600/2500 | Galvanised steel |
| RLH | 2.22 | 10 | 600/2500 | Galvanised steel |
| RLSS | 1.48 | 10 | 600/2500 | Stainless steel |
| RLMS | 1.84 | 10 | 600/2500 | Stainless steel |
Details
Applications : Metal lath used over solid surfaces to be furred approximately ¼ inch away from the wall to allow for the proper stuco keying behind the lath. Fastener placement should be arranged so as not to negate the furring mechanism.
All Metal lath is manufactured in accordance with BS 1369: Part 1 : 1987. Galvanized steel used in accordance with BS EN 10142. Stainless steel used in accordance with BS EN 10088 (Formerly known as BS 1449 : Part 2 : 1983)
Recommended
| Reference | Weight (kg./m2) | Width (mm) | Length (mtr) | Material |
|---|---|---|---|---|
| CLG 100L | 0.91 | 100 | 50/100 | Galvanized steel |
| CLG 150 L | 0.91 | 150 | 50/100 | Galvanized steel |
| CLG 200 L | 0.91 | 200 | 50/100 | Galvanized steel |
| CLG 100 M | 1.11 | 100 | 50/100 | Galvanized steel |
| CLG 150 M | 1.11 | 150 | 50/100 | Galvanized steel |
| CLG 200 M | 1.11 | 200 | 50/100 | Galvanized steel |
| CLG 100 H | 1.61 | 100 | 50/100 | Galvanized steel |
| CLG 150 H | 1.61 | 150 | 50/100 | Galvanized steel |
| CLG 200 H | 1.61 | 200 | 50/100 | Galvanized steel |
| CLG 100 EH | 1.81 | 100 | 50/100 | Galvanized teel |
| CLG 150 EH | 1.81 | 150 | 50/100 | Galvanized steel |
| CLG 200 EH | 1.81 | 200 | 50/100 | Galvanized steel |
| CLS 100 M | 1.11 | 100 | 50/100 | Stainless steel |
| CLS 150 M | 1.11 | 150 | 50/100 | Stainless steel |
| CLS 200 M | 1.11 | 200 | 50/100 | Stainless steel |
| CLS 100 H | 1.61 | 100 | 50/100 | Stainless steel |
| CLS 150 H | 1.61 | 150 | 50/100 | Stainless steel |
| CLS 200 H | 1.61 | 200 | 50/100 | Stainless steel |
Note : Other sizes are available upon request.
Details
| Reference | Weight kg/m2 | Rib Depth (D) mm | Width (W)mm | Length mm | Material |
|---|---|---|---|---|---|
| HR-S | 3.39 | 21 | 445 | 2200 | Galvanized |
| HR-M | 4.86 | 21 | 445 | 2200 | Galvanized |
| HR-H | 6.34 | 21 | 445 | 2200 | Galvanized |
Installation : Hi-rib lath is ideal for refurbishing damaged or aged masonry walls, when a key for rendering is not certain due to disintegration or softening of the wall face. Lath should be fixed with apexes of ribs against the wall, edge ribs of sheets nesting into each other should be wire-tied every 15cm and ends of sheets should be lapped not less than 2.5cm and nesting ribs securely tied together.
A correctly formed Hy-rib joint outperforms traditionally prepared joints in shear and bond. Hy-rib reduces the risk of trapped air and voids withint the concrete.
Stainless steel fixings should be used at sufficient intervals to hold the lath firmly in position.
Details
| Reference | Reference | Length (mm) | Material |
|---|---|---|---|
| CM 50 GS | 50 | 2500 | Galvanised Steel |
| CM 75 GS | 75 | 2500 | Galvanised Steel |
| CM 50 SS | 50 | 2500 | Stainless Steel |
| CM 75 SS | 75 | 2500 | Stainless Steel |
Note : Other Sizes are available upon request.