The system is the cost-effective solution for all routine fluoroscopic and radiographic examinations. The easy-to-use controls will make your room highly effective and suitable for your everyday fluoroscopy applications The system comes with high frequency generator ranging 40 or 50kW, high performance X-ray tubes and an under table bucky with floor mounted or ceiling suspended tube stand to extend the application to general radiography studies. It is quite enough to satisfy all the needs of a primary diagnostic X-ray room. A tomography column is also available to further extend the scope of application of your diagnostic room. The system is the right choice for all routine fluoroscopic and radiographic examinations. Its modular design allows several possible configurations to fit every need of a primary diagnostic X-ray room. It features a motorized tilting movement between +90 degree (vertical) and -15 degree (trendelemburg) with automatic stop at limits. The system comes equipped with an innovative multi-format Spot Film Device for cassettes ranging in size from 18cm x 24cm to 35cm x 43cm - the ideal configuration form film based exposures with subdivisions in both directions up to 4 on1. Series acquisition can be performed up to a maximum of 4 exposures in 4 seconds, and "one-hand cassette loading" in each table position makes easy cassette insertion. Ceiling suspended tube stand is designed for a wide range of movement for 4 directions with electromagnetic locks. Large dual LED display and counterbalanced spring type provides complete protection and easy operation. The system tilting table slides 2 different ways to support patient positioning for proper fluoroscopic use. The table top endures more than 200kg weight with smooth operation. The extensive travel range of the spot film device, together with the longitudinal and transverse movement of the flat tabletop, provides a true head-to-toe examination area. Features : Microcontroller and computer integration deliver reliability and accurate exposure parameter management.APR operating mode with 288 examinations distributed across 8 anatomical regions.Simple and user-friendly technique reprogramming on site.Special CPU program manages and controls tube filament functioning and stable X-ray exposure performance. Manual override technology permits the operator to modify the recommended kV, mA and time.Sophisticated self-diagnostic capability and descriptive error messaged allow for fast and well-defined initial diagnostics.Compact display console is ideally suited for small control rooms. Comprehensive service program provides accurate troubleshooting and minimize downtime.Automatic Exposure Control can support either four solid state detectors or ion chambers. (Option)Automatic Brightness Stabilizer produces optimal fluoroscopic images. (Option)Supports one or two x-ray tubes in either radiographic or radiographic and fluoroscopic mode.
features : professional hardware technology. its performance is credible and steady.multi processing unit parallel dispose technology, which makes data collection and graphics display more rapid it has 4 channels, which satisfies different work models in the clinic emg examination.low noise, high cmrr, montage programmable electrode junction box. independently programmable stimulators allow sophisticated examinations.professional electromygram operation space, shortcut and steady.intraoperative monitor capability.high speed and completely self-motion data collection and analysis, more niceties and more rapid with electrical stimulus, voice stimulus and light stimulus.usb 2.0 connection to pc or laptop function : emg testscs testmcs testf wave testh reflex testblink reflex testrns testbaep testvep testsep test
Specifications
| Maximum injection rate | 1500 ml/h (Different syringes have different maximum flow rate.) |
|---|---|
| Injection flow rate range | 5 ml injector: 0.1.100ml/h 10 ml injector: 0.1.200 ml/h 20 ml injector: 0.1.400 ml/h 30 ml injector: 0.1.600 ml/h 50 ml injector: 0.1.1500 ml/h |
| Injection increment | 0.1 |
| Bolus rate | 5 ml injector: 100ml/h 10 ml injector: 200 ml/h 20 ml injector: 400 ml/h 30 ml injector: adjustable from 400.600 ml/h 50 ml injector: adjustable from 400.1500ml/h |
| Injection mode selection | 1. Rate mode; 2. Time mode; 3. Body Weight mode; 4. Link mode |
| Rate mode | Rate: 0.1.1500.0ml/h (maximum value depends on the injector specifications) |
| Time mode | Time: 1minute.2000 minutes. Volume limit: 0.1ml.999.9 ml |
| Body Weight mode | Weight: 0.1.300.0 kg Drug: 0.1.999.9 mg Volume: 0.1.999.9 ml Dose: 0.1.9999.9 (restricted to unit, drug, solution, weight and injector specification). Unit: mg/kg/h, ug/kg/min |
| KVO rate | Adjustable range: 0.5.0ml/h (begin the KVO function under the occlusion situation); Setting value as 0 to cancel the KVO function when it is unnecessary in use. |
| Water-proof grade | IPX1 |
| Injection pressure | The maximum pressure is 300 kpa, occlusion alarm pressure gate value is 40kPa.160kPa, when pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes. |
| Preset volume scope | 0.1.999.9 ml |
| Preset time scope | 0.2000 minutes |
| Accumulated injection volume display | 0.1.999.9 ml |
| Injection accuracy | ±5. |
| Power supply | 100V-240V., 50Hz,±1Hz, 30VA |
| Battery | Rechargeable lithium polymer battery, 7.4V, 1600mAh |
| Maximum power consumption | 10VA, running more than 2 hours at the rate of 5ml/h after being fully charged. |
| Battery charge | When double-channel syringe pump is connected to AC power and the power is on, the battery will charge automatically. (about 8.14 hours to recharge fully) |
| Fuses | T 2AL 250V |
| Displayed and indicated information | Injection rate, accumulated volume, syringe specification, battery capacity, bed No., AC power indicator, operation indication, etc. |
| State indication information | Stop, injection, bolus, KVO ( If KVO rate is set as 0, it doesn't display KVO when occlusion alarm occurs) |
| Alarm functions | Near completion, Over, occlusion, disengage, low battery, abnormal 1, abnormal 2, abnormal 3, abnormal 4, serious low battery |
| Size of the outer shell | 320 mmx110 mmx200mm.(length x width x height) |
| Classification | Class, Type BF |
| Outer shell material | ABS Plastic |
| Operating condition | Environment temperature:.5.40, air pressure: (86.106) kPa, relative humidity: <80% |
| Storage condition | Environment temperature:.40.55, air pressure: (50.106) kPa, relative humidity: <95%. No poisonous gas and well ventilation |
| Applicable syringes | National standard syringes: 5ml, 10 ml, 20 ml, 30ml, 50 ml |
| Standards | GB9706.1-2007, GB 9706.27-2005, ISO7886-1:1993, GB9969.1-1998, GB/T14710.1993, GB191-2008, YY0466-2003 |
Measure Precision
| Item | Linearity(mmol/L) | Slope | Lifespan |
|---|---|---|---|
| K+ | 0.01-99.00 | 58.0 | 12 months |
| Na+ | 1.0-999.0 | 58.0 | 8 months |
| Cl- | 1.0-999.0 | 56.0 | 8 months |
| Ca++ | 0.01-9.9 | 28.0 | 8 months |
| Li+ | 0.01-9.9 | 56.0 | 8 months |
| PH | 3.50-10.80 | 58.0 | 12 months |
| Ref | / | / | 36 months |
Specifications
| Maximum injection rate | 1500ml/h (Different injectors have different maximum rate.) |
|---|---|
| Range of flow rate | 5ml injector: 0.1-100ml/h 10ml injector: 0.1-200ml/h 20ml injector: 0.1-400ml/h 30ml injector: 0.1-600ml/h 50ml injector: 0.1-1500ml/h |
| Injection increment | 0.1ml/h |
| Bolus rate | 5ml injector: 100ml/h 10ml injector: 200ml/h 20ml injector: 400ml/h 30ml injector: 400-600ml/h 50ml injector: 400-1500ml/h |
| Injection mode selection | 1. Rate mode 2. Time mode 3. Body Weight mode |
| Rate mode | Speed: 0.1-1500ml/h (maximum value depends on the injector specifications) |
| Time mode | Time:1-2000 minutes Accumulated injection volume: 0.1-999.9ml |
| Body Weight mode | Weight: 0.1-300.0kg Drug: 0.1-999.9(mg) Volume: 0.1-999.9ml Dose: 0.1-9999.9(restricted to unit, drug, solution, weight and injector specification). Unit: mg/kg/h, ug/kg/min |
| KVO rate | Adjustable range: 0.1ml/h-5.0ml/h (begin the KVO function under the occlusion situation) ; pressing STOP key to cancel the KVO function when it is unnecessary in use. |
| IP grade | IP21 |
| Injection pressure | The maximum pressure is 0.3Mpa, Occlusion alarm pressure value is 40kPa-160kPa when pressure value is minimum, injection rate is 25ml/h, the longest alarm time is 10 minutes. When pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes. |
| Preset volume | 0.1ml-9999.9ml |
| Preset time | 0-99 hours, 0-59 minutes |
| Accumulated injection volume | 0.1ml-9999.9ml |
| Accuracy | 3% |
| Power supply | AC 100-220V,50/60Hz |
| Battery | Rechargeable lithium polymer battery, 7.4 V, 1600mAh. |
| Maximum power consumption | 25VA, running more than 2 hours at the rate of 25ml/h after being fully charged. |
| Battery charge | When syringe pump is connected to AC power, the battery will automatically recharge. (about 8-14 hours to recharge fully.) |
| Fuses | T2AL250V- |
| Displayed information | Flow rate; accumulated injection volume; injector specification; battery capacity; bed No.; AC power indicator, operation indication, etc. |
| State indication information | Stop, inject, bolus, KVO (stop flashing, the other indicators flash by turns.) |
| Alarm information | near completion, Over, occlusion, low battery, abnormal 1 (communications failure), abnormal 2 (pump stuck), abnormal 3 (wrong parameter), volume limited alarm, no AC power |
| Maximum size of the outer shell | 288x130x122 mm ( lengthx width x height ) |
| Maximum weight | <3.0kg |
| Classification | ClassII, Type BF |
| Shell material | ABS plastic |
| Operating conditions | Environment temperature 5-40, air pressure 80kPa -106kPa,relative humidity 80% |
| Storage conditions | Environment temperature -40-55, air pressure 50kPa -106kPa,relative humidity 95% |
| Applicable syringes | 5ml.10 ml.20 ml.30ml.50 ml syringes |
| Electrical safety | In accordance with the stipulation of GB9706.1-1995 |
| Applied standards | According to the stipulation of YZB/Yue 001-2008 |