Vertical Laminar Flow

Vertical Laminar Flow Unitis designed specifically for product protection. The Cabinet is a clean bench which provides ultra clean sterile HEPA filtered class 100 air in an isolated area for operations requiring a particulate-free environment where the highly sensitive process activities are carried-out.

The Vertical laminar air Flow Unitdraws air in through the top of the unit through a pre-filter, through a plenum and vertically down over the work-surface and past the lap of the operator. It has the advantage of not pushing air into the face of the operator as in ahorizontal laminar air flow cabinet.The laminar air flow cabinets are used for work with low-risk substances and materials, when protection of working material from environment is required or work with item requires a sterile working zone. Cabinets are used for equipment of local workplaces in medical, pharmaceutical and other institutes with high requirements for air cleanliness in the working zone.

Vertical Laminar Air Flow Unitis with a variety of standard dimensions also our unit can be custom engineered to any size. Laminar air flow available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3
Pre-filter : Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer make magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. s
Lighting : Fluorescent light with milky white diffuser (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Work Table : SS work table with due reinforcement
Side Panel : Glass side panel screens for maximum visibility
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test (with PAO solution).
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test (with PAO solution).
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on Scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with hour meter.
  • SS 304 cock for gas and air.
  • Foldable polycarbonate front door.
  • Audio visual alarm indicating condition of HEPA filters.
  • Clean down timer with operation hold indicator.
  • VFD based control systems.
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps.
  • Flame proof fitting.

Standard Model Available :

MODEL NO. HEPA FILTER AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS
CSVLAF-36-24 915 x 610    
CSVLAF-48-24 1220 x 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) /
SMVLAF-36-24-30 915 x 610 90(fpm) Class 100 (U.S. FED STD 209 E)
SMVLAF-48-30-30 1220 x 762    

View Complete Details

Weighing Booth Extractor

Weighing Booth Extractoris designed specifically for powder containment applications, the Powder weighing enclosure employs carefully directed inward airflow at the face of the enclosure to hazardous powders or potent pharmaceutical compounds. The aerodynamically designed enclosure reduces airflow turbulence for maximum containment while minimizing the effect that air drafts may have on sensitive weighing balances. The enclosure design exceeds the containment requirements of proven by independent type testing. All exhaust air is HEPA-filtered, removing virtually all particulate matter, before recirculation to the laboratory.

weighing booth extractor Unitiswith a variety of standard dimensions also our cabinet can be custom engineered to any size. Weighing Booth Extractor available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

MODEL NO. WORKING AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
WBE-48-36 1260 X 955 X 2170 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical –
WBE-48-48 1275 X 1260 X 2170 90(fpm) Class 100 (U.S. FED STD 209 E) Recirculatory

Technical Specification :

Exhaust
HEPA filter :
Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at exhaust position with an efficiency rating better than 99.999% for 0.3µ.
Pre-filter : Prefilter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 Grade, with an efficiency rating better than 95% down to 5µ.
Motor
Alower Assembly :
Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA filter.
Lighting : Fluorescent light (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Control System : Electrical control panel mounted on the side panel of the unit.
Door : SS 304 double walled door construction with flush glass view panels with door closer, SS handles and SS hinges
Door
release
(Push type) :
Door release provides from the front of the unit.
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Exhaust Duct : SS 304 1 ft long elbow duct for exhaust
Side Panel : SS 304 Double Walled Side Panels.
Electrical Supply : 230V AC 1Ø 50Hz / 415 V AC 3Ø 50 Hz
Noise Level : Less than 67 dB on scale ‘A’ when ambient is not greater than 55 dB on scale ‘A’
Vibration Level : Minimum

Optional Accessories :

  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • SS Perforation table for keeping weighing scale/p>
  • Sodium vaporlamps
  • Flame proof fitting
  • Safe change bag in / bag out arrangement for filters
  • Double skin side panels with view windows
  • Service access from front / back / side
  • Horizontal internal coving at base




View Complete Details

Unidirection Air Flow Benches

Unidirectional Air FlowBenches offers highest product protection for samples and processes by providing ISO Class 5 particle free work area. Unidirectional Air Flow Unit draws air in through the top of the unit through a pre-filter, through a plenum and vertically down over the work-surface and past the lap of the operator. It has the advantage of not pushing air into the face of the operator as in a vertical laminar flow cabinet.

It prevents contamination from operator and environment to work area. The laminarity of the flow prevents cross contamination between the items handled in the working space. These units are suitable for the handling of non-hazardous products, sensible to dust and/or to contamination wherever operator protection is not required.

Unidirectional Air Flow Unitswith a variety of standard dimensions also our cabinet can be custom engineered to any size. Unidirectional air flow are available in powderTechnical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Pre-filter : Fresh Air filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Lighting : Fluorescent light (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Control Panel : Electrical control panel mounted on the side panel of the unit.
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Side Panel : Double skin side panels with glass view panel
Electrical Supply: : 230V AC 1 50Hz / 415V AC 3 Hz
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • Front Anti-static PVC Curtains
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelicguage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

MODEL NO. HEPA FILTER AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
UDAF-48-36 1220 X 915 0.45±0.05mps / ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical
UDAF-48-48 1220 X 1220 90(fpm) Class 100 (U.S.FED STD 209 E) -Recirculatory

View Complete Details

Bio-safety Cabinet

Biological safety cabinetis designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertical laminar airflow to create a barrier to airborne particles and microorganisms. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaust with the HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter, It is a contaminant-free environmental Protection.

Biological Safety Cabinetrange includes a variety of containment products to suit laboratory applications within the academic, pharmaceutical, biotech, healthcare, R&D and industrial sectors. Our advanced biological safety cabinets have been designed with safety and efficiency in mind. User-friendly features and advanced control systems make these cabinets both versatile and reliable. The biosafety cabinets are classified into three categoriesClass I , Class IIorClass IIIprovides a range of solutions for the containment of category.

Class II :The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered re circulated mass airflow within the workspace.The exhaust air from the cabinet is also filtered by HEPA filter. Thus, Class II bio safety cabinet provides protection to product as well as to human beings and environment. While HEPA filters are effective for trapping particulates and infectious agents, it is suitable for the containment of bio hazardous material thereby providing sterile environment for cell culture. Class II cabinet is most versatile and economical model.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
ExhaustHEPA filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at exhaust position with an efficiency rating better than 99.999% for 0.3.
Pre-filter : Fresh Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorBlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 2 Nos.) to monitor pressure drop across HEPA filter & work area with respect to ambient.
Lighting : Fluorescent light (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
SS 304 work table : SS 304 work table with perforations at front & back which can be removed occasionally for cleaning purpose
front door : 1-piece fully openable sliding toughened glass with counterweight arrangement
DoorOpening Alarm : Alarm triggers in case front door is raised more than 8 (i.e. safe clear door opening during operation)
Exhaust Duct : SS 304 stands with leveling lugs
Side panel : Double walled flushed glass side panels
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on Scale A
Vibration Level : Minimum

Optional Accessories :

    • Front door with gloves and glove port arrangement
    • Transfer hatch for material movement
    • PLC based control system
    • U.V. Light with hour meter
    • SS 304 cock for gas and air
    • Foldable polycarbonate front door
    • Audio visual alarm indicating condition of HEPA filters
    • Clean down timer with operation hold indicator
    • VFD based control systems
    • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.

Sodium vaporlamps

  • Flame proof fitting
  • Safe change bag in / bag out arrangement for filters

MODEL NO. WORKING AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
BSC-36-24-24 915 X 610 X 610 0.45±0.05mps ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical –
BSC-48-24-24 1220 X 610 X 610 90(fpm) Class 100 (U.S.FED STD 209 E) Recirculatory
 


View Complete Details

Mobile Trolley

Mobile Trolleyis designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area for storing sterile products to meet storage needs while making a positive contribution to maintaining the cleanliness of your controlled cleanroom environment. The work area is continuously supplied with positive pressure HEPA filtered recirculated vertical / horizontal air flow. Our range ofmobile trolley cabinetis available in various specifications as per the clients requirements.Mobile Trolleyis with a variety of standard dimensions also our Mobile Trolley can be custom engineered to any size. Mobile Trolley is available in powder coated Mild Steel, SS 304 / 316 / 316L or a combination of both.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Return Air Pre-filter : Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
Fresh Air Filter : Fresh Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10.
Motor Alower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Door : SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges.
Interlocking : Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens.
Shelves : SS 304 hanging arrangement (or) removable type shelves
Temperature Control : Heater with thermostat for control of temperature in cabinet
Battery back-up : Battery back-up with inverter for 30 mins
Castrol wheel : PU coated lockable castor wheels
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Handle : SS 304 Handle for mobility
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with Hour Meter used for bacteria/virus killing & interlocking arrangement to put off UV Light if either side door opens.
  • Electro-Magnetic / Mechanical Interlocking
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelicguage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

Standard Model Available :

MODEL NO. WORK AREA (MM) AIRFLOW VELOCITY (DOWN FLOW) AIR CLEANLINESS AIR FLOW
MT-24-24-24 610 X 610 X 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) / Horizontal – Recirculatory
MT-24-24-36 610 X 610 X 915 90(fpm) Class 100 (U.S. FED STD 209 E)
View Complete Details

Garment Storage Cabinet

Garment Storage Cabinetis designed to provide ISO Class 5 (Class 100) particle free work area for storing sterile packed garments to meet garment storage needs while making a positive contribution to maintaining the cleanliness of your controlled cleanroom environment.

Cleanroom garments can accumulate particulate contamination during storage and between laundry washes, which in turn may lead to lower product yields and increased product quality issues. The work area is continuously supplied with positive pressure HEPA filtered re-circulated vertical / horizontal air flow.

These are widely used for storage of clean apparel for clean rooms as these are equipped with HEPA filter and U.V. germicidal tube. Therefore, these are safe and ensure that the garments completely free from bacterial contamination.

Our range ofGarment Storage Cabinetis available in various specifications as per the clients requirements. Garment Storage Cabinet is with a variety of standard dimensions also our Garment Cabinet can be custom engineered to any size. Garment Storage Cabinet available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

:Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
ReturnAir Pre-filter : Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
FreshAir Filter : Fresh Air Filter Made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Door : SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges.
Interlocking : Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens.
Shelves : SS 304 hanging arrangement (or) removable type shelves
Temperature Control : Heater with thermostat for control of temperature
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with Hour Meter used for bacteria/virus killing & interlocking arrangement to put off UV Light if either side door opens.
  • 6/15 amp single-phase switch socket for external equipment
  • Electro-Magnetic / Mechanical Interlocking
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps

Standard Model Available :

MODEL NO. WORK AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
GSC-24-24-24 610 X 610 X 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical / Horizontal
GSC-24-24-36 610 X 610 X 915 90(fpm) Class 100 (U.S. FED STD 209 E) – Recirculatory
GSC-36-24-24 915 X 610 X 610     (Based on application)

View Complete Details

Mobile Laminar Air Flow Unit

Mobile Laminar Air Flow Unitis designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area to ensure product integrity. The work area is continuously supplied with positive pressure HEPA filtered recirculated horizontal air flow.

Mobile Laminar Air Flow Unitis with a variety of standard dimensions also our cabinet can be custom engineered to any size. Mobile Laminar air flow available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.echnical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Pre-filter : Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorBlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Lighting : Fluorescent light with milky white diffuser (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Control Panel : Electrical control panel mounted in the unit.
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test with (PAO) solution.
Battery back-up : Battery back-up with inverter for 30 mins
Handel : SS 304 handle for mobility
Castrol wheel : PU coated lockable castor wheels
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • Anti-static PVC strip overlapping curtains
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelicguage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

Standard Model Available :

MODEL NO. WORKING AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
MLAF-36-30-30 915 x 760 x 760  
MLAF-48-30-30 1220 x 760 x 760 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) /  
MLAF-60-30-30 1525 x 760 x 760 90(fpm) Class 100
(U.S. FED STD 209 E)
Vertical
MLAF-72-30-30 1830 x 760 x 760


View Complete Details

Horizontal Laminar Air Flow Workstation

The Horizontal Laminar Flow workstationis designed specifically for highest product protection by providing ISO Class 5 particle free work area for handling critical process. The main HEPA filter is situated immediately behind the working area; clean air is then blown across the work surface towards the operator. The work area is continuously supplied with positive pressure HEPA filtered horizontal air flow. It prevents contamination from operator and environment to work area. The laminarity of the flow prevents cross contamination between the items handled in the working space.

These units are suitable for the handling of non-hazardous products, sensible to dust and/or to contamination wherever operator protection is not required.

Horizontal Laminar Air Flow Unitis with a variety of standard dimensions also our cabinet can be custom engineered to any size. Horizontal Laminar air flow are available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Pre-filter : Made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Lighting : Fluorescent light with milky white diffuser (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Work Table : SS work table with due reinforcement
Side Panel : Glass side panel screens for maximum visibility
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with hour meter
  • SS 304 cock for gas and air
  • Foldable polycarbonate front door
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

Standard Model Available :

MODEL NO. WORK AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
HLAF-36-24-24 915 x 610 x 610
HLAF-48-24-24 1220 x 610 x 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) /  
HLAF-48-24-30 1220 x 610 x 760 90(fpm) Class 100
(U.S. FED STD 209 E)
Horizontal
 



View Complete Details

Gates And Grills

We have manufacturing of all type (Standard and non standard) of ss furniture as per cGMP

View Complete Details

Air Pack Technical System

Air Pack Technical SolutionsHVAC provides world class environmental control for high precision industries like pharmaceutical, Biotech, Healthcare, Food & Beverages, Research & Development labs, electronics and semi conductors, manufacturing industries and hospitality industry.

Some of the important components of the wide product range include:
  • Pharma grade hygienic Air Handling Units
  • Hygienic design to meet highest international Air Pack Technical Solutions.
  • Smooth surfaces with inside covering
  • Anti Microbial sealing
  • Leak proof service doors
  • Stainless steel drain pans
  • High efficiency plug fan
  • Built in variable frequency drives
  • Easy connectivity to Building Management system / Environment control system.
Fan Filter Units
  • They are ideal for use in new Cleanroom construction or changing non clean areas into classified clean zones in Pharmaceutical, Biotech and research laboratories.
  • Compact & highly efficient.
  • Unidirectional airflow of Ultra clean HEPA filtered Air
  • Low energy consumption
Factory mode ducting
  • Pre fabricated ductwork as per International standards of SMACNA
  • Superior supports & line of connections
  • Easy erection & commissioning at site.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Air Pack Solutions from Panchkula, Haryana.
Post Buy Requirement
AP
Panchkula, Haryana, India
Add Review

Other Products / Services #5767879

Vertical Laminar Flow

Vertical Laminar Flow Unitis designed specifically for product protection. The Cabinet is a clean bench which provides ultra clean sterile HEPA filtered class 100 air in an isolated area for operations requiring a particulate-free environment where the highly sensitive process activities are carried-out.

The Vertical laminar air Flow Unitdraws air in through the top of the unit through a pre-filter, through a plenum and vertically down over the work-surface and past the lap of the operator. It has the advantage of not pushing air into the face of the operator as in ahorizontal laminar air flow cabinet.The laminar air flow cabinets are used for work with low-risk substances and materials, when protection of working material from environment is required or work with item requires a sterile working zone. Cabinets are used for equipment of local workplaces in medical, pharmaceutical and other institutes with high requirements for air cleanliness in the working zone.

Vertical Laminar Air Flow Unitis with a variety of standard dimensions also our unit can be custom engineered to any size. Laminar air flow available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3
Pre-filter : Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer make magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. s
Lighting : Fluorescent light with milky white diffuser (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Work Table : SS work table with due reinforcement
Side Panel : Glass side panel screens for maximum visibility
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test (with PAO solution).
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test (with PAO solution).
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on Scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with hour meter.
  • SS 304 cock for gas and air.
  • Foldable polycarbonate front door.
  • Audio visual alarm indicating condition of HEPA filters.
  • Clean down timer with operation hold indicator.
  • VFD based control systems.
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps.
  • Flame proof fitting.

Standard Model Available :

MODEL NO. HEPA FILTER AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS
CSVLAF-36-24 915 x 610    
CSVLAF-48-24 1220 x 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) /
SMVLAF-36-24-30 915 x 610 90(fpm) Class 100 (U.S. FED STD 209 E)
SMVLAF-48-30-30 1220 x 762    

View Complete Details

Weighing Booth Extractor

Weighing Booth Extractoris designed specifically for powder containment applications, the Powder weighing enclosure employs carefully directed inward airflow at the face of the enclosure to hazardous powders or potent pharmaceutical compounds. The aerodynamically designed enclosure reduces airflow turbulence for maximum containment while minimizing the effect that air drafts may have on sensitive weighing balances. The enclosure design exceeds the containment requirements of proven by independent type testing. All exhaust air is HEPA-filtered, removing virtually all particulate matter, before recirculation to the laboratory.

weighing booth extractor Unitiswith a variety of standard dimensions also our cabinet can be custom engineered to any size. Weighing Booth Extractor available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

MODEL NO. WORKING AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
WBE-48-36 1260 X 955 X 2170 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical –
WBE-48-48 1275 X 1260 X 2170 90(fpm) Class 100 (U.S. FED STD 209 E) Recirculatory

Technical Specification :

Exhaust
HEPA filter :
Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at exhaust position with an efficiency rating better than 99.999% for 0.3µ.
Pre-filter : Prefilter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 Grade, with an efficiency rating better than 95% down to 5µ.
Motor
Alower Assembly :
Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA filter.
Lighting : Fluorescent light (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Control System : Electrical control panel mounted on the side panel of the unit.
Door : SS 304 double walled door construction with flush glass view panels with door closer, SS handles and SS hinges
Door
release
(Push type) :
Door release provides from the front of the unit.
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Exhaust Duct : SS 304 1 ft long elbow duct for exhaust
Side Panel : SS 304 Double Walled Side Panels.
Electrical Supply : 230V AC 1Ø 50Hz / 415 V AC 3Ø 50 Hz
Noise Level : Less than 67 dB on scale ‘A’ when ambient is not greater than 55 dB on scale ‘A’
Vibration Level : Minimum

Optional Accessories :

  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • SS Perforation table for keeping weighing scale/p>
  • Sodium vaporlamps
  • Flame proof fitting
  • Safe change bag in / bag out arrangement for filters
  • Double skin side panels with view windows
  • Service access from front / back / side
  • Horizontal internal coving at base




View Complete Details

Unidirection Air Flow Benches

Unidirectional Air FlowBenches offers highest product protection for samples and processes by providing ISO Class 5 particle free work area. Unidirectional Air Flow Unit draws air in through the top of the unit through a pre-filter, through a plenum and vertically down over the work-surface and past the lap of the operator. It has the advantage of not pushing air into the face of the operator as in a vertical laminar flow cabinet.

It prevents contamination from operator and environment to work area. The laminarity of the flow prevents cross contamination between the items handled in the working space. These units are suitable for the handling of non-hazardous products, sensible to dust and/or to contamination wherever operator protection is not required.

Unidirectional Air Flow Unitswith a variety of standard dimensions also our cabinet can be custom engineered to any size. Unidirectional air flow are available in powderTechnical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Pre-filter : Fresh Air filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Lighting : Fluorescent light (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Control Panel : Electrical control panel mounted on the side panel of the unit.
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Side Panel : Double skin side panels with glass view panel
Electrical Supply: : 230V AC 1 50Hz / 415V AC 3 Hz
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • Front Anti-static PVC Curtains
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelicguage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

MODEL NO. HEPA FILTER AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
UDAF-48-36 1220 X 915 0.45±0.05mps / ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical
UDAF-48-48 1220 X 1220 90(fpm) Class 100 (U.S.FED STD 209 E) -Recirculatory

View Complete Details

Bio-safety Cabinet

Biological safety cabinetis designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertical laminar airflow to create a barrier to airborne particles and microorganisms. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaust with the HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter, It is a contaminant-free environmental Protection.

Biological Safety Cabinetrange includes a variety of containment products to suit laboratory applications within the academic, pharmaceutical, biotech, healthcare, R&D and industrial sectors. Our advanced biological safety cabinets have been designed with safety and efficiency in mind. User-friendly features and advanced control systems make these cabinets both versatile and reliable. The biosafety cabinets are classified into three categoriesClass I , Class IIorClass IIIprovides a range of solutions for the containment of category.

Class II :The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered re circulated mass airflow within the workspace.The exhaust air from the cabinet is also filtered by HEPA filter. Thus, Class II bio safety cabinet provides protection to product as well as to human beings and environment. While HEPA filters are effective for trapping particulates and infectious agents, it is suitable for the containment of bio hazardous material thereby providing sterile environment for cell culture. Class II cabinet is most versatile and economical model.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
ExhaustHEPA filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at exhaust position with an efficiency rating better than 99.999% for 0.3.
Pre-filter : Fresh Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorBlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 2 Nos.) to monitor pressure drop across HEPA filter & work area with respect to ambient.
Lighting : Fluorescent light (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
SS 304 work table : SS 304 work table with perforations at front & back which can be removed occasionally for cleaning purpose
front door : 1-piece fully openable sliding toughened glass with counterweight arrangement
DoorOpening Alarm : Alarm triggers in case front door is raised more than 8 (i.e. safe clear door opening during operation)
Exhaust Duct : SS 304 stands with leveling lugs
Side panel : Double walled flushed glass side panels
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on Scale A
Vibration Level : Minimum

Optional Accessories :

    • Front door with gloves and glove port arrangement
    • Transfer hatch for material movement
    • PLC based control system
    • U.V. Light with hour meter
    • SS 304 cock for gas and air
    • Foldable polycarbonate front door
    • Audio visual alarm indicating condition of HEPA filters
    • Clean down timer with operation hold indicator
    • VFD based control systems
    • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.

Sodium vaporlamps

  • Flame proof fitting
  • Safe change bag in / bag out arrangement for filters

MODEL NO. WORKING AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
BSC-36-24-24 915 X 610 X 610 0.45±0.05mps ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical –
BSC-48-24-24 1220 X 610 X 610 90(fpm) Class 100 (U.S.FED STD 209 E) Recirculatory
 


View Complete Details

Mobile Trolley

Mobile Trolleyis designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area for storing sterile products to meet storage needs while making a positive contribution to maintaining the cleanliness of your controlled cleanroom environment. The work area is continuously supplied with positive pressure HEPA filtered recirculated vertical / horizontal air flow. Our range ofmobile trolley cabinetis available in various specifications as per the clients requirements.Mobile Trolleyis with a variety of standard dimensions also our Mobile Trolley can be custom engineered to any size. Mobile Trolley is available in powder coated Mild Steel, SS 304 / 316 / 316L or a combination of both.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Return Air Pre-filter : Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
Fresh Air Filter : Fresh Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10.
Motor Alower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Door : SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges.
Interlocking : Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens.
Shelves : SS 304 hanging arrangement (or) removable type shelves
Temperature Control : Heater with thermostat for control of temperature in cabinet
Battery back-up : Battery back-up with inverter for 30 mins
Castrol wheel : PU coated lockable castor wheels
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Handle : SS 304 Handle for mobility
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with Hour Meter used for bacteria/virus killing & interlocking arrangement to put off UV Light if either side door opens.
  • Electro-Magnetic / Mechanical Interlocking
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelicguage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

Standard Model Available :

MODEL NO. WORK AREA (MM) AIRFLOW VELOCITY (DOWN FLOW) AIR CLEANLINESS AIR FLOW
MT-24-24-24 610 X 610 X 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) / Horizontal – Recirculatory
MT-24-24-36 610 X 610 X 915 90(fpm) Class 100 (U.S. FED STD 209 E)
View Complete Details

Garment Storage Cabinet

Garment Storage Cabinetis designed to provide ISO Class 5 (Class 100) particle free work area for storing sterile packed garments to meet garment storage needs while making a positive contribution to maintaining the cleanliness of your controlled cleanroom environment.

Cleanroom garments can accumulate particulate contamination during storage and between laundry washes, which in turn may lead to lower product yields and increased product quality issues. The work area is continuously supplied with positive pressure HEPA filtered re-circulated vertical / horizontal air flow.

These are widely used for storage of clean apparel for clean rooms as these are equipped with HEPA filter and U.V. germicidal tube. Therefore, these are safe and ensure that the garments completely free from bacterial contamination.

Our range ofGarment Storage Cabinetis available in various specifications as per the clients requirements. Garment Storage Cabinet is with a variety of standard dimensions also our Garment Cabinet can be custom engineered to any size. Garment Storage Cabinet available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

:Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
ReturnAir Pre-filter : Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
FreshAir Filter : Fresh Air Filter Made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Door : SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges.
Interlocking : Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens.
Shelves : SS 304 hanging arrangement (or) removable type shelves
Temperature Control : Heater with thermostat for control of temperature
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with Hour Meter used for bacteria/virus killing & interlocking arrangement to put off UV Light if either side door opens.
  • 6/15 amp single-phase switch socket for external equipment
  • Electro-Magnetic / Mechanical Interlocking
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps

Standard Model Available :

MODEL NO. WORK AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
GSC-24-24-24 610 X 610 X 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) / Vertical / Horizontal
GSC-24-24-36 610 X 610 X 915 90(fpm) Class 100 (U.S. FED STD 209 E) – Recirculatory
GSC-36-24-24 915 X 610 X 610     (Based on application)

View Complete Details

Mobile Laminar Air Flow Unit

Mobile Laminar Air Flow Unitis designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area to ensure product integrity. The work area is continuously supplied with positive pressure HEPA filtered recirculated horizontal air flow.

Mobile Laminar Air Flow Unitis with a variety of standard dimensions also our cabinet can be custom engineered to any size. Mobile Laminar air flow available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.echnical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Pre-filter : Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorBlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Lighting : Fluorescent light with milky white diffuser (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Control Panel : Electrical control panel mounted in the unit.
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test with (PAO) solution.
Battery back-up : Battery back-up with inverter for 30 mins
Handel : SS 304 handle for mobility
Castrol wheel : PU coated lockable castor wheels
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • Anti-static PVC strip overlapping curtains
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelicguage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

Standard Model Available :

MODEL NO. WORKING AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
MLAF-36-30-30 915 x 760 x 760  
MLAF-48-30-30 1220 x 760 x 760 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) /  
MLAF-60-30-30 1525 x 760 x 760 90(fpm) Class 100
(U.S. FED STD 209 E)
Vertical
MLAF-72-30-30 1830 x 760 x 760


View Complete Details

Horizontal Laminar Air Flow Workstation

The Horizontal Laminar Flow workstationis designed specifically for highest product protection by providing ISO Class 5 particle free work area for handling critical process. The main HEPA filter is situated immediately behind the working area; clean air is then blown across the work surface towards the operator. The work area is continuously supplied with positive pressure HEPA filtered horizontal air flow. It prevents contamination from operator and environment to work area. The laminarity of the flow prevents cross contamination between the items handled in the working space.

These units are suitable for the handling of non-hazardous products, sensible to dust and/or to contamination wherever operator protection is not required.

Horizontal Laminar Air Flow Unitis with a variety of standard dimensions also our cabinet can be custom engineered to any size. Horizontal Laminar air flow are available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.

Technical Specification :

Supply filter : Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3.
Pre-filter : Made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5.
MotorAlower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
Differential Pressure Gauge : Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA.
Lighting : Fluorescent light with milky white diffuser (250 Lux) at work surface
ON/OFF Switches : SS ON/OFF switches for motor & lights
Switch Socket : 6/15 amp single-phase switch socket use for external equipment
Work Table : SS work table with due reinforcement
Side Panel : Glass side panel screens for maximum visibility
DOP Port : DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
Electrical Supply : 230V AC 1- 50HZ / 415V AC 3- 50HZ
Noise Level : Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A
Vibration Level : Minimum

Optional Accessories :

  • U.V. Light with hour meter
  • SS 304 cock for gas and air
  • Foldable polycarbonate front door
  • Audio visual alarm indicating condition of HEPA filters
  • Clean down timer with operation hold indicator
  • VFD based control systems
  • Photohelic guage / Digital pressure gauge to monitor of pressure drop across filter.
  • Sodium vaporlamps
  • Flame proof fitting

Standard Model Available :

MODEL NO. WORK AREA (MM) AIRFLOW VELOCITY
(DOWN FLOW)
AIR CLEANLINESS AIR FLOW
HLAF-36-24-24 915 x 610 x 610
HLAF-48-24-24 1220 x 610 x 610 0.45±0.05mps/ ISO Class 5 (ISO 14644-1:1999 (E)) /  
HLAF-48-24-30 1220 x 610 x 760 90(fpm) Class 100
(U.S. FED STD 209 E)
Horizontal
 



View Complete Details

Gates And Grills

We have manufacturing of all type (Standard and non standard) of ss furniture as per cGMP

View Complete Details

Air Pack Technical System

Air Pack Technical SolutionsHVAC provides world class environmental control for high precision industries like pharmaceutical, Biotech, Healthcare, Food & Beverages, Research & Development labs, electronics and semi conductors, manufacturing industries and hospitality industry.

Some of the important components of the wide product range include:
  • Pharma grade hygienic Air Handling Units
  • Hygienic design to meet highest international Air Pack Technical Solutions.
  • Smooth surfaces with inside covering
  • Anti Microbial sealing
  • Leak proof service doors
  • Stainless steel drain pans
  • High efficiency plug fan
  • Built in variable frequency drives
  • Easy connectivity to Building Management system / Environment control system.
Fan Filter Units
  • They are ideal for use in new Cleanroom construction or changing non clean areas into classified clean zones in Pharmaceutical, Biotech and research laboratories.
  • Compact & highly efficient.
  • Unidirectional airflow of Ultra clean HEPA filtered Air
  • Low energy consumption
Factory mode ducting
  • Pre fabricated ductwork as per International standards of SMACNA
  • Superior supports & line of connections
  • Easy erection & commissioning at site.