Our Products
Leading Manufacturer, Supplier & Retailer of LOANZA AGAROSE, AMPLATE ROLLER, LOW RETENTION, PURE CELLULOSE BLOTING SHEET and SONAR - QUALITATIVE FILTER PAPERS.
The conjugate pad is made of a non-absorbent material such as fiberglass pad, polyester, rayon or a similar material. The conjugate pad is always of a synthetic material (at least when using a gold conjugate) to ensure the efficient release of its contents. As its name implies, the assays' detection conjugate is dried down and held in place here until a liquid test sample is applied to the sample pad. This liquid sample, moves into the conjugate pad by capillary action, rehydrates the dry gold conjugate, allowing the sample to mix with the conjugate. The complex of gold conjugate and analyte then moves into and up the membrane. Pretreatment of the conjugate pad helps to ensure the conjugate releases at the proper rate and enhances its stability. The pretreatment is performed in the same way as with the sample pad.
| Good uniformity | Hydrophilic | High absorption | Good wicking rate | Wide compatibility |
PURE CELLULOSE BLOTING SHEET
Thickness 0.8 mm
No. 101 (Sheets) Filter speed-medium fast, Retention-medium crystalline Ideal for general laboratory filtration, sugar syrup filtration No. 101 (Circles)
| Cat No. | Size cm | Nos.of Sheet/Pkt. | Nos.of Pkts per std Box |
|---|---|---|---|
| 101465 | 46 X 57 | 100 | 5 PKT. |
| 101657 | 46 X 57 cm | 500 | 3 PKT. |
| 101666 | 66 X 66 | 250 | 1 PKT. |
THREE PLACE ASSEMBLY S. S. FUNNELS 250ml (with inbuilt Clamp)
| Cat. No.TP3 / SWN2 With 500 ml S. S. Funnel (with Inbuilt Clamp) | |
|---|---|
| Filter Funnel S.S.316 with inbuilt S. S. Clamp S. S. lid & Neoprene Cork Capacity - 500 ml (FFSSN 50SM) | Three |
For ensuring a perfect seal when using either secureseal thermal sealing film or foil on PCR plates. Roller made of medium hard rubber. Heavy-duty handle with comfort grip reducing grip reducing fatigue. Will last a long time
| Cat. No. | Size | Qty/Pkt |
|---|---|---|
| T329-9 | 10.16 cm (4") | 1 |
Minimum retention = Maximum accuracy No Silicon additives = No leaching Manufactured from specially developed resins combined with high quality diamond finish mould creates super hydrophobic internal surface and ensure maximum recovery of sample yield.
Warning Instruction and Sterilization indicator patch Autoclavable disposable waste bag of very strong PP-lm with a broad seam at the bottom, for the sterilization and disposal of hazardous and contaminated labware. rectangle white indicator field turns into dark when autoclaved with BIOHAZARD sticker and safety imprint in English autoclavable at 134 C, for autoclaving, the bag must not be completely closed
| at No. | W x H mm |
Volume approx. L |
Film Thickness |
Packaging | Quantity per Pack |
|---|---|---|---|---|---|
| 70 02 100 | 300 x 500 | 8 | 50 µm | cardboard box 1 x 500 |
500 |
| 70 02 150 | 400 x 780 | 38 | 50 µm | cardboard box 1 x 500 |
500 |
| 70 02 200 | 600 x 800 | 60 | 50 µm | cardboard box 1 x 500 |
500 |
| 70 02 300 | 700 x 1100 | 110 | 50 µm | cardboard box 1 x 500 |
500 |
Seakem LE Agarose is the ideal multipurpose , molecular biology grade agarose for any DNA or RNA application wide resolution range : 100 bp 23 kb High gel strength - Ideal for Southern and Northern blotting
Application :
Broad range fragment separationSouthern and northern blottingPCR greater than 1 kbimmunoprecipition techniquescolony lifts Storage condition 18c 26c
CAT NO : AX50004 - SeaKem LE Agarose 500 gms BottleCAT NO : AX50184 - MetaPhorTM Agarose 500 gmsCAT NO : AX50180 - MetaPhorTM Agarose 125 gms
Feather touch controller, plate mounted on the door.Digital Display L. E. D + L. C. D. BothContinuous display of set temperature, attained temperature, time, day, date, etcAs soon as the set temperature is attained, timer start automatically & raise thealarm after the set time is over (Fully automatic).LED indicator for door open, power failure, sensor failureBattery operated controller with indication of power failure70% higher uses through trouble free adjustment of trays anywhere at a gap 4cms
1. M. C. B. is provided at the mains of the connection, 2. Overheat Protection controller is provided additionally which protects in case of controller failure3. Fuses are provided on every electrical line to safeguard each and every component.r
SPECIFICATIONEnergy Efficient MechanismLow Noise and Vibration LevelsLong Life and Low maintenanceConforms to US Federal Standard Class 100Supplied with spares kitGuaranteed supply of spares for 10 yearsOnsite installation and after sales service by company trained engineers
| Inside S.S. 304 & Outside M.S. | Inside & Outside both S.S. 304 | Inside S.S. 316 & Outside S.S. 304 | Size of Inside Chamber (HxWxD) in mm | Volume cu. ft. | Capacity Liters |
|---|---|---|---|---|---|
| BOD-5642M | BOD-5642S | BOD-5642S 316 | 560 x 420 x 380 | 3 cu. ft. | 85 Ltrs |
| BOD-6145M | BOD-6145S | BOD-6145S 316 | 610 x 455 x 410 | 4.5 cu. ft. | 128Ltrs |
| BOD-8450M | BOD-8450S | BOD-8450S 316 | 840 x 500 x 410 | 6 cu. ft. | 170 Ltrs |
| BOD-9958M | BOD-9958S | BOD-9958S 316 | 990 x 580 x 490 | 10 cu. ft. | 285 Ltrs |
| BOD-1062M | BOD-1062S | BOD-1062S 316 | 1020 x 620 x 520 | 12cu. ft. | 340 Ltrs |
| BOD-7064M | BOD-7064S | BOD-7064S 316 | 700 x 640 x 900 | 15 cu. ft. | 421 Ltrs |
SPECIFICATION
| Working Temp. are ON. | 5°C to 60oC or 10°C to 60°C when lights |
| Temp. Accuracy | ± 1oC (or 0.5°C under ideal conditions) |
| Temp. Readability | 0 .1°C |
| Power supply | 220V, 50Hz, Single Phase AC supply |
Controller mounted on the door (no separate panel)Feather Touch LED + LCD both display with Digital TimerOnce the set temperature is attained, timer starts working automaticallyRaises alarm if the temperature overshoot/ undershootContinuous display on L. C. D. of Set Temp., Attained Temp., Set Time, Heating On/Off.Display of door open (if door is not closed) & heater gets switched off automatically.Indicators of Auto-mode, Sensor failure, Alarm & Heating70% higher use through trouble free adjustment of trays anywhere at a gap 4cms
M. C. B. is provided at the mains of the connectionOverheat controller is provided additionally which protect to control in case of controller failureFuses are provided on every electrical line to safeguard each and every component.
| Cat No. | Chamber Size (W x H x D) | Cap. Ltrs. | No. Shelf. |
|---|---|---|---|
| SDO-3535 | 355 X 355 X 355 (14" x 14" x 14") | 45 | 2 |
| SDO-4545 | 455 X 455 X 455 (18" x 18" x 18") | 95 | 2 |
| SDO-4560 | 455 X 605 X 455 (18" x 24" x 18") | 125 | 2 |
| SDO-6060 | 605 X 605 X 605 (24" x 24" x 24") | 224 | 2 |
| SDO-6090 | 605 X 910 X 450 (24" x 36" x 18") | 252 | 3 |
| SDO-6096 | 605 X 910 X 605 (24" x 36" x 24") | 336 | 3 |
| SDO-9191 | 910 X 910 X 910 (36" x 36" x 36") | 796 | 3 |
| Construction | Double Walled |
| Inside Chamber | S. S. 304 grade. (S. S. 316 Optional) |
| Outside Chamber | Made of Mild steel/G.I. sheet duly painted (S. S. 304 optional). |
| Temperature Controller | Door mounted digital |
| Door | Single Door. |
| Timer | Digital, automatic, inbuilt |
| Shelves | Strong stainless steel wire shelves |
| Ventilation | Provided on both side. |
| Gasket | Door gasket made of silicon/ asbestos |
| Gasket | 3 Nos. made of S. S. wire.The trays can be adjusted anywhere at a distance of 4cms. |
SPECIFICATION
| Temperature Range | Ambient ± 5°C to 250°C |
| Accuracy | ± 1°C at 100°C (under ideal conditions) |
| Readability | 0.5°C |
| Temperature Controller | Door mounted digital |
| Timer | Digital, automatic, inbuilt |
| Power Supply | 220 V, Single phase, 50 Hz, AC supply |
Type of Output: Constant-Voltage, Current or PowerIncrement: 1V, 1mA, 1WOutput Range: 5-200V, 1-2000mA, 1-200W.Timer Range: 1min99hr, 59min Display: LCD display with backlightOutput jacks: Four sets of output jacks.
CHARACTERISTIC FEATURESMolding shell, touch keys, dual core microprocessor intelligent control;Indicate the preset value and the actual output value at the same time;It can store 10 electrophoresis methods;With automatic memory function;With standard, timing operation function;With constant voltage, constant current, constant power, misoperation, fault intelligent prompt functions;Automatic detection of no-load, over-load, short circuit, rapid resistance change, ground leak and system overheating.
Type of Output: Constant-Voltage, CurrentOutput range: JY300: 5300Vx 1 300mAs maximum 90WIncrement: 1V, 1mATimer Range: 1min9hr, 59minDisplay: LEDOutput jacks: Two sets of output jacks Volume(LxWxH): 280x237x118Weight: 3.0(kg)
CHARACTERISTIC FEATURESMolding shell, touch keys, microprocessor intelligent control; With automatic memory function; With standard, timing operation function; Automatic detection of no-load, over-load.
Type of Output: Constant-Voltage, CurrentOutput range: JY300: 5300Vx 1 300mAs maximum 90WIncrement: 1V, 1mATimer Range: 1min9hr, 59minDisplay: LEDOutput jacks: Two sets of output jacks Volume(LxWxH): 280x237x118 Weight: 3.0(kg)
CHARACTERISTIC FEATURESMolding shell, touch keys, microprocessor intelligent control;With automatic memory function;With standard, timing operation function;Automatic detection of no-load, over-load.
Combined logging with GLP EC/TDS/NaCl/Temp bench meter; range: EC 0.00 to 29.99 S/cm; 30.0 to 299.0 S/cm; 3 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; to 500.0 mS/cm without cat; TDS range 0.00 to 14.99 mg/L (ppm); 150 to 1499 mg/L (ppme); 1.50 to 14.99 g/L (ppt); 15.0 to 100 g/L (ppt); to 400.0 g/L; NaCl range 0 to 400%. Temp range: -9.9 to 120.0C. 1 point calibration for EC with 6 memorized values. NaCl with 1 point. Supplied with MA814DB/1 probe, electrode holder MA9315, software Mi5200, RS232 connection with 2 meter cable, 12 VDC adapter and calibration solutions.
Combined logging with GLP DO/Temp bench meter; range: DO: 0.00 to 45.00 mg/L (ppm) and 0.0 to 300.0%; Temp -5C to 55.0C. Resolution: 0.01 ppm to 0.1%, 0.1C. Automatic calibration in one or two points at 0% (with MA9070 solution) or 100% (in air) of O2. Automatic altitude compensation 0 to 4000 m. Automatic salinity compensation 0 to 40 g/L. Automatic temperature compensation 0.0 to 50.0C. Supplied complete with DO probe MA840, electrolyte solution MA9071S, 2 membranes, Mi5200 software, RS232 connection with 2 meter cable, 12 VDC adapter and calibration solution.
8 Place Closed Rotor for 1.5 / 2.0 ml tube quiet & powerful operation6000 RPM / 2000 gElectronic Safety BrakeMicroprocessor Powered programmable personal centrifugeDigital Display of speed with speed control knobDigital Variable TimerSMPS Universal Electronic Power SupplyImbalance cut-off safety feature (First time ever patented)Digital Calibration Function8 Slot x 1.5 / 2.0 ml Closed rotorPCR Strip rotor (2 x 8 x 0.2 ml)Reduction adapter for 0.2 / 0.4ml microtube