Our Complete range of products are Inline Static Mixer, Proximity 3 Wire Transmitter, Pneumatic Actuator, Intrinsically Safe Limit Switch and Temperature Switch.
FeatureRugged construction, Bottom/ back entry, every angle construction, Fast response, High repeatability, low hysteresis, Hermetically sealed case . .
SystemGas (N2) filled case compensated in accordance with SAMA Cl. IIIB
Dial100 mm / 150 mm in aluminium, white background, black marking
CaseSS304 / SS316 with bayonet bezel (Flameproof case in Al only)
ProtectionWeatherproof to IP-67 (IS/IEC
StemSS304 or SS316, 6 mm, 8 mm, 10 mm, 12 mm dia as standard
Connection1/2″ NPT (M) adjustable three piece compression fitting as standard Capillary SS Covered / SS Covered + PVC / SS Covered + SS armoured / SS Covered + SS Armoured +PVC (up to 25 Mtr.).
Range(-) 200 to 800°C (minimum span 80°C )
Accuracy± 1% FSD for indication, ± 2% FSD for switching
ApplicationThe Hair-Pin heat exchanger are used in system requiring a moderate quantity of heat exchange with low flow rates and with temperature ranges requiring a perfect countercurrent flow.
Design Temperature250°C
Number of Tube side passes1, 2 & 4
Tube Diameter19.05 mm x 1.6 mm thk (Seamless & welded option )
FeatureHigh pressure drop multiple stage labyrinth control valves, Anti-clog design, Multi-stage, labyrinth plug, Flow area expands towards the downstream, Standardised high performance material .
Number Of FlowerMIL 77000 Multiple Stage Labyrinth Control Valve
FeatureMulti-step anti-cavitation and low noise control valves, Multi-step axial flow high resistance plug, High allowable pressure drops with low pressure recovery, Adiabatic flow with friction .
RatingANSI 300# to ANSI 2500#
Number Of FlowerMIL 78000 -Multi-Stage Control Valve
FeatureExtreme pressure multi-stage and multi-path anti- cavitation control valves, Tortuous flow path with high impedance for energy absorption, Varying and expanding flow path, Dynamically stable,
Number Of FlowerMIL 91000 -Multi-Stage, Multi-Path Control Valve
FeatureSelf Actuating , Heavy Guiding, High Capacity with low recovery, Reduced trim capacity, High performance materials, Downstream and Upstream Pressure control,
Features / BenefitFull Bore, Reduce Bore Blow Out Proof Stem Low Torque, Anti-static Device, Extended Stem, Floating Ball, Fire Safe Test Requirement as per API 607 & API 6FA Mounting Pad on request
Features / BenefitCentric, Single Ecentric & Double Eccentric Design Top Mounting Pad as per ISO 5211 Unique Stem retention design & easy assembly & disassembly of valves Heavy Duty square grooved seat design with moulded O ring seals to act as flange gasket
MaterialBody -WCB, CF8, CF8M, Hast Alloy, Super Duplex, Alloy 20 , LCB etc Trim : 13 % Cr, Stellite etc
Features / BenefitOS & Y Constructione Flexible Wedge Design (Choice of Solid or Split Wedge Available) Full Port DesignRenewable Seat Rings & Integral Seat Rings Burnish Finish Stem for Low Operating Torque Pressure Seal Bonnet or Welded Bonnet on request
Features / BenefitHeavy duty Spring providing intantaneous response to system change PTFE spacers designed to maintain plate alignment Lifting Bolt Provided for easy installation
FeatureExtremely robust design , Optimized flow, proven in our test field, For control service at high pressure, Piston and crank mechanism, Optimized for high flow rate .
Torque25 to 6, 00, 000 Nm for rotary and 1.2 to 8000 kN force for linear actuator
ConstructionCasting -Cast Aluminium , Actuator -Refer DRS Series Actuator Catalouge
Ingress ProtectionIP68 10m / 96h
Controls locationAs standard, the controls are integral to the actuator On option, the Controller can be mounted in a separated box (maximum distance between actuator and controls = 50m)
Explosion proof ATEXATEX Directive 94/9/EC – CENELEC EN 60079-0, EN60079-1, EN13463 As standard: Ex d II B T4 (option T5 or T6) and Ex tb IIIC T135°C (option T100°C, T85°C) On request: Ex d II C T4 (option T5 or T6)
Explosion proof IEC ExIEC Ex – standard IEC 60079-0, IEC60079-1, EN13463 As standard: Ex d II B T4 (option T5 or T6) and Ex tb IIIC T135°C (option T100°C, T85°C) On request: Ex d II C T4 (option T5 or T6)
Ambient temperature operating rangeIIB standard: -20 … +70°C IIB low temperature option: -60 … +70°C IIC option: -20 … +70°C
GeneralLoop powered, no external power supply required. External 24V DC option available. Blind mount Suitable for rotary and linear valves Actuator connections in accordance with VDI/VDE 3845 and IEC 60534-6 standards. Extensive selection of moun
ActionDouble or single acting
FailsafeFailsafe or Stay-put (Fail freeze)
Linear0 position can start anywhere, 3 to 200 mm stroke, other strokes on request
Rotary0° can start anywhere, max. 359°
Measurement range0 to 359° with freely rotating contactless feedback shaft , 0 to 300 seconds (configurable in incremental steps of 60 Seconds).
Actuator travel limitFreely configurable in 0% to 100%
Deadband time limit0 to 300 seconds (freely configurable, monitoring parameter until deviations reaches within deadband)
Standard temperature range-20 °C to +85 °C / -4 °F to +185 °F
Low temperature range-40 °C to +85 °C / -40 °F to +185 °F , -55 °C to +135 °C / -67 °F to 185 °F available on request
Influence of temperature on valve position0.35% / 10 °K
Influence of vibration on valve position< 1 % under 10g 5–85 Hz, 2.5 85-150 Hz 1.5g 150–280 Hz, 0.5g 280–1500 H
PurityAluminum cast (copper free) case with epoxy potting for better environmental protection and reliability, Does not require proximity probe driver .
Number Of FlowerTR3101 Proximity 3-Wire Transmitter for Radial Shaft Vibration