Post Buy Requirement
CI
Kolkata, West bengal, India
Add Review

Our Products #9206074

CLIP-ON POWER FACTOR METER

  • Frequency 47 - 53 H Z
  • Weight 1.8 kg (approx)
  • Core - Gap 55 mm Maximum
  • Dielectric Test Voltage 2 KVAC ( r.m.s. ) for 1 min.
  • Insulation Resistance Test Over 25 ohm at 500v DC
  • Scale length 70 mm (approx)
  • Dimensions (In mm) 330 x 99 x 98
  • Response Time Less than 1.8 kg (approx)
  • Calibration 50 H 1 AC Supply
  • Confirms to IS 1248 - 1983
  • Accuracy ± 3* (expressed as phase angle)
  • Indicator Analogue, Moving Coil Type Indicating Meter
  • Accessories (Standard) (1) Potential Leads - 1 pair, (2) Operator"s Manual - 1No. (3) Carrying Case - 1N0. Accessory (optional), Neutral Box.
View Complete Details

Motorised Insulation Tester

  • Feature Accurate, Quick response and Graceful Appearance, Operated by 230volts, 50Hz AC mains
  • Scale Length 100mm (approx.)
  • Mains Supply 230V, 50Hz
  • Accuracy As per IS: 2992-1987
  • Dimensions (in inch) 14 x 10 x 10 (approx.) (Incl. Top Cover)
  • Weight (Incl. Top Cover) 9 kg. (approx.)for CIE/777 & 12 kg. (approx.) for CIE/777HM
  • Standard Mains cord (2mtrs length) - 1 No
  • Optional (At extra cost) H. V. Testing leads - 1 pair (2mtrs length), Rexine carrying case
  • Optional Extra Facility (at extra cost) 15 minuites Timer Facility
  • Response Time 3 seconds
  • High Voltage Test Withstands minimum 2 KV or (rated voltage + 1) KV A.C. (rms) for 1 min. between the electrical circuit & containing case
  • Insulation Resistance Test Better than 50 Megohms at 500 V D.C. between the electrical circuit & the containing case
View Complete Details

HIGH VOLTAGE BREAKDOWN TESTER

  • SALIENT FEATURES Robust Powder Coated Sheet Metal Case, Elegant Look, KV Meter to Read The Output Voltage, Millimeter to Show Leakage Current, Speedy and Accurate Testing of Breakdown/Withstand Test of Electrical & Electronic Components, Materials, Equipments, Panel Board Etc
  • Input Voltage 230V, +/- 10%, 50Hz, 1 phase A.C.
  • Output Voltage Continiously variable from(i) 0 to 3 KV AC for 3 KV Test Set(ii) 0 to 5 KV AC for 5 KV Test Set
  • Capacity 50 mA maximum in the H.V. Side
  • Tripping Current 25 mA & 50 mA (Toggle Switch Provided)
  • Duty Cycle Intermittent i.e., 5 minuites 'ON' & 10 minuites 'OFF'
  • MODE OF OPERATION Manual
View Complete Details

ELECTRIC MOTOR CHECKER

  • Weight 2.335 kg (with Batteries) (Approx)
  • Insulation Resistance 0-20 Megohms at 500 V DC, Max. Current 0.25 mA (with electronic Zero set facility)
  • Resistance 0-60 Megohms in 6 ranged (0-0.2 Megohms FSD in Range 1) (i.e. 0-0.2 / 0.6 / 2 / 6 / 20 / 60 Megohms marked as % on dial)
  • Inductance 0-300 mH in 6 ranged (0-1 mH FSD in Range 1) (i.e. 0-1 / 3 / 10 / 30 / 100 / 300 mH, Marked as % on dial)
  • Self Battery Test To check the condition of the battery of the instrument itself
  • Power Source 1.5V x 6 Nos AA size cells or 230V AC, 50Hz (Provided with inbuilt 9V Battery Eliminator Adaptor)
  • Dimensions 233mm x 216mm x 115mm (Approx)
  • SALIENT FEATURES Spring Loaded Shock Proof Pivot Jewel Type indicating meter, Most reliable and perfect actioned Rotary Switches for function and range selection, Push to test, to Save Power, Electronic zero Set for Insulation Resistance, Self Battery Test
View Complete Details

Digital Earth Tester

  • Display 3½ Digits, LCD
  • Standard Accessories (i) Carrying Case (ii) Charging Cord (iii) Instruction Manual
  • Optional Accessories (at extra cost) 4 Nos. M. S. Spike (45 cm Length) • 4 Nos. Rolls of flexible wire wound on spool ( 10 mts., 20 mts,
  • AVAILABLE IN DUAL RANGES (a) 0 - 20 - 200 OHM (b) 0 - 10 - 1000 OHM (c) 0 - 100 - 1000 OHM (d) 0 - 5 - 500 OHM (e) 0 - 10 - 1
  • SALIENT FEATURES Rugged ABS body, Easy to use hand held meter, Ni-cd Re- chargeable Cells, Facility as to make bench top type instrument, Confirms to ISS : 9223/1979, Four terminals (To measure earth resistance as well as specific soil resistivity), Lo-Bat or Δ indication appe
View Complete Details

AC CLAMP METER

  • Weight 1.6 Kg (approx.)
  • Accuracy +/- 5% F.S.D. for Current, +/- 3% F.S.D. for Voltage
  • Calibration 50Hz, A.C. Supply
  • Scale Length 50mm (approx.)
  • Core Gap 55mm Maximum (approx.)
  • Dimensions (In mm) 330 x 99 x 88 (approx.)
  • H. V. Test 2KV AC (rms) for 1 min.
  • Insulation Resistance Test Over 20 Megohms at 500 V DC

MODEL NO A. C. CURRENT A. C. VOLTAGE
R7VA1
R7VA2
R7VA3
R4A2V
R2A3V1
R2A3V2
R7A
0-10/30/100/300/1000A
0-10/25/100/250/1000A
0-50/100/250/500/1000A
0-50/100/200/400A
0-60/300A
0-25/125A
0-10/25/50/100/250/500/1000A
0-300/600V
0-300/600V
0-300/600V
0-300/600V
0-150/300/600V
0-150/300/600V
N.A.


















View Complete Details

PHASE SEQUENCE INDICATOR

  • Frequency 25-60Hz
  • Standard Accessories Rexine carrying case
  • Working Voltage 100V to 500V AC at 25Hz to 65Hz
  • Dimensions 96mm x 96mm
  • Rating 30 seconds @ 500 V, Burden – 15VA @ 500 V, Voltage – 50-500V (in horizontal position), 100-500V (in vertical position)
View Complete Details

DIGITAL INSULATION TESTER

  • Application Ideal for Insulation Measurement of Electrical Equipments (Motor, Transformer, Machine etc.), Household Appliances ( Mixer, Toaster, Washing Machine Etc., ), Industrial, Commercial & Residential Installations, Electrical Cables for Distribution Networks, Cable
  • SPECIAL FEATURES Rugged ABS body, Easy to use hand held meter, Ni-cd Re-chargeable Cells, Facility as to make benchtop type instrument, Accurate and Quick response, Graceful Appearance, Direct Measurement of Insulation Resistance, Lo-Bat Indication on Display
  • Display 3 1/2 Digits, L.C.D.
  • Accuracy Insulation ± 3% of F.S. ± 5 digits. Out put Voltage (DC) ±10% at rated resistance
  • Confirms to ISS 10656 - 1983
  • Dimensions (in mm) 172x98x38 (Approx)
  • H. V. Test 2KV AC (r.m.s.) For 1 min.Between electrical circuit and containing case.
  • Insulation Resistance Test More than 50 M Ohm at 500V DC between electrical circuit & containing case.
  • Standard Accessories Carrying Case, Charging Cord, Testing Lead (1m length), Instruction Manual
  • Guarantee Guaranteed for 12(twelve) months against any manufacturing defects.
View Complete Details

Digital Clamp Meter

  • Frequency 2 kHz , 20 kHz
  • Display 3½ Digit, 1999 counts, liquid Crystal Display
  • Jaw opening capability 55mm (max. conductor size)
  • DC VOLTAGE 2V / 20V / 200V / 1000V
  • AC VOLTAGE 200V / 750V
  • AC CURRENT 20A / 200A / 1000A
  • RESISTANCE 200 OHM / 20K OHM / 2 M OHM
  • TEMPERATURE 0ºC TO 750ºC
  • SALIENT FEATURES Accurate, Reliable, Safe, Easy to Use, Attractive Look, Large LCD For Easy Reading, Back Light Display, Data Hold Facility, Low Battery Indication, Diode & Audible Continuity Test Facility
View Complete Details

DIGITAL MULTIMETER

  • Operating Temperature 0 - 40ºC, 32ºF - 122ºF (<80% RH, <10ºC non-condencing)
  • Power Source 4.5V
  • Weight 360g. Approx (Battery Included).
  • Application With Frequency, Temperature, Voltage, Resistance, Diode & Audible continuity testing.
  • Display 3¾ Digits, LCD Display . Automatic Indication of functions & symbols
  • Range Selections Automatic & Manual
  • Over Range Indication LCD will display "OL"
  • Low Battery Indication The *±* is displayed when the battery is under the proper operation range.
  • Polarity Indication *_* displayed automatically
  • STORAGE TEMPERATURE -10 - 60ºC, 14ºF - 140ºF (<70% RH, battery removed )
  • Fuse Protection uA and mA , F500 / mA / 250V 5X20, A , F 10A / 250V 6.3X32.
  • Sample Range 3 times / sec for digital data
  • Battery Type AAA 1.5V.
  • Dimensions 185(L) X 87 (W) X53 (H) mm.
  • SPECIAL FEATURES Secondary Injection Moulded Case, VAC, VDC, mVDC, ohms, Capacitance, Frequency (upto 100kHz), AC / DC amps, AC / DC milliamps, AC / DC micro-amps, Temperature ( -50*C - 100*C ), Relative mode, DATA Hold
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Browse Our Products list of Cambridge Instruments & Engineering Co. Kolkata, West bengal
Post Buy Requirement
CI
Kolkata, West bengal, India
Add Review

Our Products #9206074

CLIP-ON POWER FACTOR METER

  • Frequency 47 - 53 H Z
  • Weight 1.8 kg (approx)
  • Core - Gap 55 mm Maximum
  • Dielectric Test Voltage 2 KVAC ( r.m.s. ) for 1 min.
  • Insulation Resistance Test Over 25 ohm at 500v DC
  • Scale length 70 mm (approx)
  • Dimensions (In mm) 330 x 99 x 98
  • Response Time Less than 1.8 kg (approx)
  • Calibration 50 H 1 AC Supply
  • Confirms to IS 1248 - 1983
  • Accuracy ± 3* (expressed as phase angle)
  • Indicator Analogue, Moving Coil Type Indicating Meter
  • Accessories (Standard) (1) Potential Leads - 1 pair, (2) Operator"s Manual - 1No. (3) Carrying Case - 1N0. Accessory (optional), Neutral Box.
View Complete Details

Motorised Insulation Tester

  • Feature Accurate, Quick response and Graceful Appearance, Operated by 230volts, 50Hz AC mains
  • Scale Length 100mm (approx.)
  • Mains Supply 230V, 50Hz
  • Accuracy As per IS: 2992-1987
  • Dimensions (in inch) 14 x 10 x 10 (approx.) (Incl. Top Cover)
  • Weight (Incl. Top Cover) 9 kg. (approx.)for CIE/777 & 12 kg. (approx.) for CIE/777HM
  • Standard Mains cord (2mtrs length) - 1 No
  • Optional (At extra cost) H. V. Testing leads - 1 pair (2mtrs length), Rexine carrying case
  • Optional Extra Facility (at extra cost) 15 minuites Timer Facility
  • Response Time 3 seconds
  • High Voltage Test Withstands minimum 2 KV or (rated voltage + 1) KV A.C. (rms) for 1 min. between the electrical circuit & containing case
  • Insulation Resistance Test Better than 50 Megohms at 500 V D.C. between the electrical circuit & the containing case
View Complete Details

HIGH VOLTAGE BREAKDOWN TESTER

  • SALIENT FEATURES Robust Powder Coated Sheet Metal Case, Elegant Look, KV Meter to Read The Output Voltage, Millimeter to Show Leakage Current, Speedy and Accurate Testing of Breakdown/Withstand Test of Electrical & Electronic Components, Materials, Equipments, Panel Board Etc
  • Input Voltage 230V, +/- 10%, 50Hz, 1 phase A.C.
  • Output Voltage Continiously variable from(i) 0 to 3 KV AC for 3 KV Test Set(ii) 0 to 5 KV AC for 5 KV Test Set
  • Capacity 50 mA maximum in the H.V. Side
  • Tripping Current 25 mA & 50 mA (Toggle Switch Provided)
  • Duty Cycle Intermittent i.e., 5 minuites 'ON' & 10 minuites 'OFF'
  • MODE OF OPERATION Manual
View Complete Details

ELECTRIC MOTOR CHECKER

  • Weight 2.335 kg (with Batteries) (Approx)
  • Insulation Resistance 0-20 Megohms at 500 V DC, Max. Current 0.25 mA (with electronic Zero set facility)
  • Resistance 0-60 Megohms in 6 ranged (0-0.2 Megohms FSD in Range 1) (i.e. 0-0.2 / 0.6 / 2 / 6 / 20 / 60 Megohms marked as % on dial)
  • Inductance 0-300 mH in 6 ranged (0-1 mH FSD in Range 1) (i.e. 0-1 / 3 / 10 / 30 / 100 / 300 mH, Marked as % on dial)
  • Self Battery Test To check the condition of the battery of the instrument itself
  • Power Source 1.5V x 6 Nos AA size cells or 230V AC, 50Hz (Provided with inbuilt 9V Battery Eliminator Adaptor)
  • Dimensions 233mm x 216mm x 115mm (Approx)
  • SALIENT FEATURES Spring Loaded Shock Proof Pivot Jewel Type indicating meter, Most reliable and perfect actioned Rotary Switches for function and range selection, Push to test, to Save Power, Electronic zero Set for Insulation Resistance, Self Battery Test
View Complete Details

Digital Earth Tester

  • Display 3½ Digits, LCD
  • Standard Accessories (i) Carrying Case (ii) Charging Cord (iii) Instruction Manual
  • Optional Accessories (at extra cost) 4 Nos. M. S. Spike (45 cm Length) • 4 Nos. Rolls of flexible wire wound on spool ( 10 mts., 20 mts,
  • AVAILABLE IN DUAL RANGES (a) 0 - 20 - 200 OHM (b) 0 - 10 - 1000 OHM (c) 0 - 100 - 1000 OHM (d) 0 - 5 - 500 OHM (e) 0 - 10 - 1
  • SALIENT FEATURES Rugged ABS body, Easy to use hand held meter, Ni-cd Re- chargeable Cells, Facility as to make bench top type instrument, Confirms to ISS : 9223/1979, Four terminals (To measure earth resistance as well as specific soil resistivity), Lo-Bat or Δ indication appe
View Complete Details

AC CLAMP METER

  • Weight 1.6 Kg (approx.)
  • Accuracy +/- 5% F.S.D. for Current, +/- 3% F.S.D. for Voltage
  • Calibration 50Hz, A.C. Supply
  • Scale Length 50mm (approx.)
  • Core Gap 55mm Maximum (approx.)
  • Dimensions (In mm) 330 x 99 x 88 (approx.)
  • H. V. Test 2KV AC (rms) for 1 min.
  • Insulation Resistance Test Over 20 Megohms at 500 V DC

MODEL NO A. C. CURRENT A. C. VOLTAGE
R7VA1
R7VA2
R7VA3
R4A2V
R2A3V1
R2A3V2
R7A
0-10/30/100/300/1000A
0-10/25/100/250/1000A
0-50/100/250/500/1000A
0-50/100/200/400A
0-60/300A
0-25/125A
0-10/25/50/100/250/500/1000A
0-300/600V
0-300/600V
0-300/600V
0-300/600V
0-150/300/600V
0-150/300/600V
N.A.


















View Complete Details

PHASE SEQUENCE INDICATOR

  • Frequency 25-60Hz
  • Standard Accessories Rexine carrying case
  • Working Voltage 100V to 500V AC at 25Hz to 65Hz
  • Dimensions 96mm x 96mm
  • Rating 30 seconds @ 500 V, Burden – 15VA @ 500 V, Voltage – 50-500V (in horizontal position), 100-500V (in vertical position)
View Complete Details

DIGITAL INSULATION TESTER

  • Application Ideal for Insulation Measurement of Electrical Equipments (Motor, Transformer, Machine etc.), Household Appliances ( Mixer, Toaster, Washing Machine Etc., ), Industrial, Commercial & Residential Installations, Electrical Cables for Distribution Networks, Cable
  • SPECIAL FEATURES Rugged ABS body, Easy to use hand held meter, Ni-cd Re-chargeable Cells, Facility as to make benchtop type instrument, Accurate and Quick response, Graceful Appearance, Direct Measurement of Insulation Resistance, Lo-Bat Indication on Display
  • Display 3 1/2 Digits, L.C.D.
  • Accuracy Insulation ± 3% of F.S. ± 5 digits. Out put Voltage (DC) ±10% at rated resistance
  • Confirms to ISS 10656 - 1983
  • Dimensions (in mm) 172x98x38 (Approx)
  • H. V. Test 2KV AC (r.m.s.) For 1 min.Between electrical circuit and containing case.
  • Insulation Resistance Test More than 50 M Ohm at 500V DC between electrical circuit & containing case.
  • Standard Accessories Carrying Case, Charging Cord, Testing Lead (1m length), Instruction Manual
  • Guarantee Guaranteed for 12(twelve) months against any manufacturing defects.
View Complete Details

Digital Clamp Meter

  • Frequency 2 kHz , 20 kHz
  • Display 3½ Digit, 1999 counts, liquid Crystal Display
  • Jaw opening capability 55mm (max. conductor size)
  • DC VOLTAGE 2V / 20V / 200V / 1000V
  • AC VOLTAGE 200V / 750V
  • AC CURRENT 20A / 200A / 1000A
  • RESISTANCE 200 OHM / 20K OHM / 2 M OHM
  • TEMPERATURE 0ºC TO 750ºC
  • SALIENT FEATURES Accurate, Reliable, Safe, Easy to Use, Attractive Look, Large LCD For Easy Reading, Back Light Display, Data Hold Facility, Low Battery Indication, Diode & Audible Continuity Test Facility
View Complete Details

DIGITAL MULTIMETER

  • Operating Temperature 0 - 40ºC, 32ºF - 122ºF (<80% RH, <10ºC non-condencing)
  • Power Source 4.5V
  • Weight 360g. Approx (Battery Included).
  • Application With Frequency, Temperature, Voltage, Resistance, Diode & Audible continuity testing.
  • Display 3¾ Digits, LCD Display . Automatic Indication of functions & symbols
  • Range Selections Automatic & Manual
  • Over Range Indication LCD will display "OL"
  • Low Battery Indication The *±* is displayed when the battery is under the proper operation range.
  • Polarity Indication *_* displayed automatically
  • STORAGE TEMPERATURE -10 - 60ºC, 14ºF - 140ºF (<70% RH, battery removed )
  • Fuse Protection uA and mA , F500 / mA / 250V 5X20, A , F 10A / 250V 6.3X32.
  • Sample Range 3 times / sec for digital data
  • Battery Type AAA 1.5V.
  • Dimensions 185(L) X 87 (W) X53 (H) mm.
  • SPECIAL FEATURES Secondary Injection Moulded Case, VAC, VDC, mVDC, ohms, Capacitance, Frequency (upto 100kHz), AC / DC amps, AC / DC milliamps, AC / DC micro-amps, Temperature ( -50*C - 100*C ), Relative mode, DATA Hold
View Complete Details