Post Buy Requirement
Chromatography and Instruments Company.
Vadodara, Gujarat, India
Verified Add Review

Gas Analyzers #1397586

Trace Gas Analyzer

  • Brand Name CIC
  • Color Grey
  • Automation Grade Automatic
  • Country of Origin Made in India
  • Model Name/Number CIC-ONGLC
  • Usage/Application Air Gases, Doping Gases, Chemical Gases, Nuclear Plants, Refineries, Petro-chemicals
  • Product Type Process/Continous/Online
  • Power Supply 230 V
  • Display Type 1/4 inch VGA Touch Screen Display
  • Power 15 Amperes
  • Dimension Tailor made to application
  • Material SS + MS + Peek - Depending upon application
  • Range PPM, PPB, PPT and Percentage
  • Capacity Single Stream and Multi Stream
  • Accuracy Accuracy +- 2.5% of scale
  • Control Detector Lamp Gas Control
  • Usage Area Process Plants, Space Application, Purity Analysis, Impurity Analysis, Cryogenic Gases Analysis
  • Frequency User Programmable
  • Voltage 230 V
  • Grade MIL / IEC


View Complete Details

Dissolved Gas Analyzer

Manufacturing and supplying of supreme quality Gas Chromatography System hashelped us achieve a very high level of trust in the market. This system has got big display that shows all the set, actual temperature and status of GC on a single page. It consists of a user friendly keypad which is separate for every menu. High sensitivity of flame ionization detector marks it as a winner.
View Complete Details

Portable Dissolved Gas Analyzer

1 Lakh /Piece Get Latest Price
  • Min. Order (MOQ) 1
  • Type Portable Dissolved Gas Analyzer
  • Weight 5-10kg
  • Brand Name Kelman GE
  • Application Mission Critical Industrial Transformers
  • Power 115-230 V AC
  • Range 1 um~400 um
  • Features Measurement of seven diagnostic gases and moisture content in the oil
  • Operating Pressure 760-1040 milibar
  • Touch Screen Intuitive touchscreen interface with step-by-step instructions and Plug and Play connectivity.

The PAS-PDGA Portable Dissolved Gas Analyzer represents a new generation of test equipment for analysis the dissolved gas in oil.Dissolved Gas Analysis (DGA) and moisture measurement of insulating fluids are recognized as the most important tests for condition assessment of fluid-insulated transformers. Every year asset owners deploy field crews to take thousands of fluid samples from transformers as part of periodic health checks and for immediate operational decisions. These samples are sent to offsite laboratories for analysis. Transport X is a portable lab in a box delivering detailed analysis with dramatically reduced turnaround times. In critical situations, the ability to perform DGA in less than 30 minutes on the spot, empowers asset owners to determine a transformers condition onsite and thereby allow operational decisions to be made at the earliest opportunity.

Additional Information:

Packaging Details : Two layer wooden carat on pallet- Export worthiness packing.

Delivery Time : 30 Days

View Complete Details

Online Dissolved Gas Analyzer

The MGA2000-6 is a new generation of On-line DGA equipment giving essential insight into the condition of transformers. Two Gas, Four Gas, Six Gas and Eight Gas models are available.

View Complete Details

Head Space TOGA Analyzer

The Touch Screen GC System Model Dhruva S2TS (NTPC & ERDA Approved) is configured For Dissolved Gas Analysis of transformer oil. It Can Be Built To Meet The Specification / Standards As Per ASTM D 3612 Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user.


This equipment can be used to detect the incipient fault in the transformer and arrest deterioration/damage to the transformer insulation by analyzing gases dissolved in the transformer oil and adopt preventive measures.


Gas Chromatography method is used for detection for the dissolved gases and identification of incipient faults. The most significant gases generated by decomposition of oil deterioration, of paper insulation on the conductor are hydrogen, methane, ethane, ethylene, acetylene, CO , Carbon di-oxide, Oxygen & Nitrogen. The quantities of these gases dissolved in transformer oil vary depending upon the type and severity of fault condition such as arcing, partial discharge, overheating, low-high temperature hot spot etc.


The process involved is separation, identification and quantitative determination of gases.The Dhruva S2TS analyzes the fault gases in a single injection with gases analysed depending upon user ordering.



Innovative & Advanced Features :



  • Color Touch Screen control with optional control over TCP-IP using FTP protocol

  • MeetsASTM D 3612 Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user.

  • 10 or 40 Vial Head Space Auto Sampler (Choice of Manual Head Space Sampling as per Section C / 7.5) .

  • Auto tuning PID temperature control for up to 8 channels with 2 programmable zones & 6 isothermal zones.

  • EPC for up to 8 channels with 2 programmable zones & 6 single set point control with 0.25% FSD accuracy.

  • Up to 12 auxiliary device control with 4 step programming for control of GSV, Solenoids, Pumps, trigger, signals etc.

  • Input status for Pressure, Remote start, Remote Stop, Door open along with 4 additional spare inputs.

  • Programmable FID (Gain, Off Set, and Sensitivity low, high) with time based sensitivity settings.

  • Programmable TCD (Sensitivity Low, Medium, High) with superb current stability & repeatability.

  • Extensive Auto diagnostics & user friendly system control with User settable password protection. Multi mode screens with 6 pages of current status giving complete GC status with option for continuous looping of the system.

View Complete Details

Micro DGA Analyzer

This equipment can be used todetecttheincipient faultin the transformer and arrest deterioration/damageto the transformer insulation byanalyzinggases dissolved in the transformer oil and adopt preventive measures.


The P Micro DGA/TOGA is capable to detect PPM & Sub PPM gases in transformer oil and can b configured for analysis as per


IS10593


IEC 60567 Section 7.3 or Section 7.5 Manual Variant


ASTM D 3612 Section A or Section C Manual Variant


The P-Micro is a microprocessor based system with no moving parts specially designed for mobile labs & easy portability. The system utilizes specialized heating techniques for the column and methanizer achieving precsion using PID control action.

View Complete Details

Hydrogen Gas Determinator

  • Dynamic Range 0.01 – 100 ppm low
  • Hydrogen 1 – 5000 ppm high
  • Precision < 1% RSD of the reading with dosing gas
  • Accuracy ± 2% FSD with dosing gas
  • Sensitivity ± 1.000 ppm for Hydrogen
  • Nominal Sample Size 1 gms
  • Analysis Time (Including Out gas) 4 minutes
  • Detection Method Macro High Flow TCD for H2
  • Sample Weight Range : 0.1 to 20 gms
  • Calibration Dual Mode – By Dosing Cavityin the system
  •   Test Mode as well as using Calibration
The analyzer is capable of the determination of Hydrogen Gas (H2) in metals and alloys with great simplicity using latest technology and menu driven software. The operation of this Hydrogen Gas Determinator analyzer is simplified with the use of Touch Screen based control systems which make the programming of all functions of the determinator extremely simple. Detection of Hydrogen gas is done using a very high sensitivity Macro Thermal Conductivity Detector capable to detect from 0.01 ppm to 5000 ppm using a nominal sample size of 1 gram for Hydrogen.





Innovative & Advanced Features


  • Compact and Modular design for ease in operation & Maintenance.

  • It has a large " VGA Touch Screen for the complete control of the system. There is no keypad or other controls visible on the front panel as the complete operation is through the touch screen panel including / excluding current setting for outgas and analyze mode. The complete system is under modbus RTU protocol for connectivity through other SCADA & supervisory systems.

  • Data acquisition is through software using a PC system so that unlimlited files can be stored.

  • All the timers are user settable (Via Supervisory password) thereby making the instrument ideal for routine analysis as well as R & D application. The timers for all the modes are set using the touch screen as well as through the H PPC Determinator control software.

  • On line display of the current mode in progress as well as the time left for mode completion displayed on the touch screen.

  • On line fault diagnosis and stepwise guidance for any fault condition on the Touch Screen console.

  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.

  • Three stage flow control system to prevent accidental change of values.

  • Alarms and safety interlocks.

  • Closed loop coolant circulator (Optional).

  • Furnace is Glove Box adaptable(Optional).


View Complete Details

Gas Analyzers

10 Lakh /Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • company specification company specification
We have pleasure in informing you that we have once again successfully manufactured
an ionization detector based gc system. This system has been manufactured against order
from barc, mumbai for analysis of hydrogen in low levels (1 -10 ppm range) in helium
background. The system has it's own very sophisticated sample handling system
commiserate with the application and system requirements.


we are pleased to attach some photographs of the system along with results taken
for the analysis of indian helium of grade 1( total impurities less than 2 ppm certified).
We will be pleased to work with you for any of your applications involving ionization based systems.

Additional Information:

Payment Terms : L/C

Packaging Details : Export Packing

Delivery Time : 2-3 Months

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gaurav Shingari (Chromatography and Instruments Company.)
  • 121-122, GIDC, Makarpura Industrial Estate, Vadodara, Gujarat - 390 010 - 390010
  • Share us via
  • Call 08068051328 Ext. 253
Retailer of Gas Analyzers from Vadodara, Gujarat by Chromatography and Instruments Company.
Post Buy Requirement
Chromatography and Instruments Company.
Vadodara, Gujarat, India
Verified Add Review

Gas Analyzers #1397586

Trace Gas Analyzer

  • Brand Name CIC
  • Color Grey
  • Automation Grade Automatic
  • Country of Origin Made in India
  • Model Name/Number CIC-ONGLC
  • Usage/Application Air Gases, Doping Gases, Chemical Gases, Nuclear Plants, Refineries, Petro-chemicals
  • Product Type Process/Continous/Online
  • Power Supply 230 V
  • Display Type 1/4 inch VGA Touch Screen Display
  • Power 15 Amperes
  • Dimension Tailor made to application
  • Material SS + MS + Peek - Depending upon application
  • Range PPM, PPB, PPT and Percentage
  • Capacity Single Stream and Multi Stream
  • Accuracy Accuracy +- 2.5% of scale
  • Control Detector Lamp Gas Control
  • Usage Area Process Plants, Space Application, Purity Analysis, Impurity Analysis, Cryogenic Gases Analysis
  • Frequency User Programmable
  • Voltage 230 V
  • Grade MIL / IEC

View Complete Details

Dissolved Gas Analyzer

Manufacturing and supplying of supreme quality Gas Chromatography System hashelped us achieve a very high level of trust in the market. This system has got big display that shows all the set, actual temperature and status of GC on a single page. It consists of a user friendly keypad which is separate for every menu. High sensitivity of flame ionization detector marks it as a winner.
View Complete Details

Portable Dissolved Gas Analyzer

1 Lakh /Piece Get Latest Price
  • Min. Order (MOQ) 1
  • Type Portable Dissolved Gas Analyzer
  • Weight 5-10kg
  • Brand Name Kelman GE
  • Application Mission Critical Industrial Transformers
  • Power 115-230 V AC
  • Range 1 um~400 um
  • Features Measurement of seven diagnostic gases and moisture content in the oil
  • Operating Pressure 760-1040 milibar
  • Touch Screen Intuitive touchscreen interface with step-by-step instructions and Plug and Play connectivity.

The PAS-PDGA Portable Dissolved Gas Analyzer represents a new generation of test equipment for analysis the dissolved gas in oil.Dissolved Gas Analysis (DGA) and moisture measurement of insulating fluids are recognized as the most important tests for condition assessment of fluid-insulated transformers. Every year asset owners deploy field crews to take thousands of fluid samples from transformers as part of periodic health checks and for immediate operational decisions. These samples are sent to offsite laboratories for analysis. Transport X is a portable lab in a box delivering detailed analysis with dramatically reduced turnaround times. In critical situations, the ability to perform DGA in less than 30 minutes on the spot, empowers asset owners to determine a transformers condition onsite and thereby allow operational decisions to be made at the earliest opportunity.

Additional Information:

Packaging Details : Two layer wooden carat on pallet- Export worthiness packing.

Delivery Time : 30 Days

View Complete Details

Online Dissolved Gas Analyzer

The MGA2000-6 is a new generation of On-line DGA equipment giving essential insight into the condition of transformers. Two Gas, Four Gas, Six Gas and Eight Gas models are available.

View Complete Details

Head Space TOGA Analyzer

The Touch Screen GC System Model Dhruva S2TS (NTPC & ERDA Approved) is configured For Dissolved Gas Analysis of transformer oil. It Can Be Built To Meet The Specification / Standards As Per ASTM D 3612 Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user.

This equipment can be used to detect the incipient fault in the transformer and arrest deterioration/damage to the transformer insulation by analyzing gases dissolved in the transformer oil and adopt preventive measures.

Gas Chromatography method is used for detection for the dissolved gases and identification of incipient faults. The most significant gases generated by decomposition of oil deterioration, of paper insulation on the conductor are hydrogen, methane, ethane, ethylene, acetylene, CO , Carbon di-oxide, Oxygen & Nitrogen. The quantities of these gases dissolved in transformer oil vary depending upon the type and severity of fault condition such as arcing, partial discharge, overheating, low-high temperature hot spot etc.

The process involved is separation, identification and quantitative determination of gases.The Dhruva S2TS analyzes the fault gases in a single injection with gases analysed depending upon user ordering.

Innovative & Advanced Features :

  • Color Touch Screen control with optional control over TCP-IP using FTP protocol
  • MeetsASTM D 3612 Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user.
  • 10 or 40 Vial Head Space Auto Sampler (Choice of Manual Head Space Sampling as per Section C / 7.5) .
  • Auto tuning PID temperature control for up to 8 channels with 2 programmable zones & 6 isothermal zones.
  • EPC for up to 8 channels with 2 programmable zones & 6 single set point control with 0.25% FSD accuracy.
  • Up to 12 auxiliary device control with 4 step programming for control of GSV, Solenoids, Pumps, trigger, signals etc.
  • Input status for Pressure, Remote start, Remote Stop, Door open along with 4 additional spare inputs.
  • Programmable FID (Gain, Off Set, and Sensitivity low, high) with time based sensitivity settings.
  • Programmable TCD (Sensitivity Low, Medium, High) with superb current stability & repeatability.
  • Extensive Auto diagnostics & user friendly system control with User settable password protection. Multi mode screens with 6 pages of current status giving complete GC status with option for continuous looping of the system.
View Complete Details

Micro DGA Analyzer

This equipment can be used todetecttheincipient faultin the transformer and arrest deterioration/damageto the transformer insulation byanalyzinggases dissolved in the transformer oil and adopt preventive measures.

The P Micro DGA/TOGA is capable to detect PPM & Sub PPM gases in transformer oil and can b configured for analysis as per

IS10593

IEC 60567 Section 7.3 or Section 7.5 Manual Variant

ASTM D 3612 Section A or Section C Manual Variant

The P-Micro is a microprocessor based system with no moving parts specially designed for mobile labs & easy portability. The system utilizes specialized heating techniques for the column and methanizer achieving precsion using PID control action.

View Complete Details

Hydrogen Gas Determinator

  • Dynamic Range 0.01 – 100 ppm low
  • Hydrogen 1 – 5000 ppm high
  • Precision < 1% RSD of the reading with dosing gas
  • Accuracy ± 2% FSD with dosing gas
  • Sensitivity ± 1.000 ppm for Hydrogen
  • Nominal Sample Size 1 gms
  • Analysis Time (Including Out gas) 4 minutes
  • Detection Method Macro High Flow TCD for H2
  • Sample Weight Range : 0.1 to 20 gms
  • Calibration Dual Mode – By Dosing Cavityin the system
  •   Test Mode as well as using Calibration
The analyzer is capable of the determination of Hydrogen Gas (H2) in metals and alloys with great simplicity using latest technology and menu driven software. The operation of this Hydrogen Gas Determinator analyzer is simplified with the use of Touch Screen based control systems which make the programming of all functions of the determinator extremely simple. Detection of Hydrogen gas is done using a very high sensitivity Macro Thermal Conductivity Detector capable to detect from 0.01 ppm to 5000 ppm using a nominal sample size of 1 gram for Hydrogen.
Innovative & Advanced Features
  • Compact and Modular design for ease in operation & Maintenance.
  • It has a large " VGA Touch Screen for the complete control of the system. There is no keypad or other controls visible on the front panel as the complete operation is through the touch screen panel including / excluding current setting for outgas and analyze mode. The complete system is under modbus RTU protocol for connectivity through other SCADA & supervisory systems.
  • Data acquisition is through software using a PC system so that unlimlited files can be stored.
  • All the timers are user settable (Via Supervisory password) thereby making the instrument ideal for routine analysis as well as R & D application. The timers for all the modes are set using the touch screen as well as through the H PPC Determinator control software.
  • On line display of the current mode in progress as well as the time left for mode completion displayed on the touch screen.
  • On line fault diagnosis and stepwise guidance for any fault condition on the Touch Screen console.
  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.
  • Three stage flow control system to prevent accidental change of values.
  • Alarms and safety interlocks.
  • Closed loop coolant circulator (Optional).
  • Furnace is Glove Box adaptable(Optional).
View Complete Details

Gas Analyzers

10 Lakh /Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • company specification company specification
We have pleasure in informing you that we have once again successfully manufactured an ionization detector based gc system. This system has been manufactured against orderfrom barc, mumbai for analysis of hydrogen in low levels (1 -10 ppm range) in heliumbackground. The system has it's own very sophisticated sample handling system commiserate with the application and system requirements. we are pleased to attach some photographs of the system along with results takenfor the analysis of indian helium of grade 1( total impurities less than 2 ppm certified). We will be pleased to work with you for any of your applications involving ionization based systems.

Additional Information:

Payment Terms : L/C

Packaging Details : Export Packing

Delivery Time : 2-3 Months

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gaurav Shingari (Chromatography and Instruments Company.)
  • 121-122, GIDC, Makarpura Industrial Estate, Vadodara, Gujarat - 390 010 - 390010
  • Share us via
  • Call 08068051328 Ext. 253