Post Buy Requirement
Chromatography and Instruments Company.
Vadodara, Gujarat, India
Verified Add Review

Other Products / Services #1397586

Oxygen Nitrogen Determinator

  • Model Number TS-ON
  • Brand Name CIC
  • Application Steel and Steel Alloy Analysis, Refractory Metal Analysis, Ceramics, Superconductors, Rare Earths
  • Type Oxygen Nitrogen Determinator
  • Power Supply 230 V AC
  • Features Data acquisition is through software using a PC system so that unlimited files can be stored
  • Color Grey
  • Automation Grade Automatic
  • Usage Area Diffusible Hydrogen Analyzer, Analysis of Non Metals, Analysis of Weld Metal, Molten Metal Analysis
  • Operating Temperature Range +18 Degree C to 24 Degree C
  • Line Voltage 230 VAC 50 Hz
  • Line Power 900 Watts
  • Water Reservoir Capacity 30+ Litres
  • Water Quality Bi- Distilled
View Complete Details

Elemental Analyzer

  • Color Grey
  • Country of Origin Made in India
  • Area Usage Copper and Copper Alloy, Nickel and Nickel Alloy, Analysis of Inorganic Materials
  • Model Name/Number H-TS
  • Usage/Application Steel and Steel Alloy Analysis, Refractory Metal Analysis, Ceramics, Superconductors, Rare Earths
  • Detector Type FID/TCD/Micro TCD/PDHID/ECD
  • Display Type It has a large 1/4
  • Water Quality Bi-Distilled
  • Operating Temperature +18 Degree C to 24 Degree C
  • Line Voltage 230 VAC 50 Hz
  • Line Power 900 Watts
View Complete Details

Carbon Sulphur Analyzer

  • Country of Origin Made in India
  • Area Usage UO2/MOX analysis, Steels and Ferro Alloys analysis, Aluminium and Aluminium Alloy Analysis
  • Model Name/Number CS-TS
  • Machine Type Automatic
  • Usage/Application Steel and Steel Alloy Analysis, Refractory Metal Analysis, Ceramics, Superconductors, Rare Earths
  • Brand Name CIC
  • Color Grey, Blue
  • Frequency 50 Hz
  • Electronic balance Upto 100 mg with 1 mg resolution
View Complete Details

Micro Gas Chromatograph System

  • Brand Name CIC
  • Application Laboratory Use
  • Weight Approx. 16 Kg
  • Automation Grade Automatic
  • Frequency 50 Hz
  • Voltage 230 V
  • Material Mild Steel
  • Power 4 Amperes
  • Color Grey
  • Country of Origin Made in India
  • Application Area Gases with sulphur group, Corrosive and Miscellaneous gases, Lower hydrocarbons, Phenols, Steroids
  • Display Inch 1/4 inch VGA Display
  • Temperature Zone Ambient to 220 Degree C
  • No. Of Detector Can be coupled with up to 2 detectors
View Complete Details

Hydrogen Gas Generator

  • Weight 7 Kgs To 200 Kgs
  • Country of Origin Made in India
  • Purity 99.995%to 99.999%
  • Application Area Light gases - Permanent Gases, Gases containing carbon group, Gases containing halogen group, Amines
  • Frequency 50 Hz
  • Generator Type Three Phase
  • Usage/Application Hydrogen Generator
  • Grade Standard Industrial Grade
  • Brand/Make CIC
  • Product Type Hydrogen Gas Generator
  • Start Up Time 15 minutes
  • Power Supply 230V AC
  • Noise <42 dB-60 dB model dependent
  • Oxygen <3ppm-1ppm
  • Water dew point -40 DegreeC
  • Outflow Speed Model Dependent
  • Outflow Pressure 60 PSIG
  • Pressure Stability <0.001 MPa
  • Flow Control & Display Accuracy +/- 5% of FSD using digital MFC system
  • Alarms Low water level, Gas leakage, Excess pressure & Low pressure
  • Rated Voltage 220 V +- 10% ; 50 Hz
  • Rated Power 200 W to 400 W dependent on model
  • Temperature 18 - 25 Degree C
  • Compressor In build in the system or external model dependent
View Complete Details

Online Partial Discharge Monitoring System

  • Voltage 100-240 V
  • Features Comprehensive monitoring of transformer bushings and PD activity on a 3 phase transformer or a bank
  • Brand Name GE Kelman
  • Usage/Application Industrial Use
  • Model Name/Number Intellix BMT 330
  • Automation Grade Automatic
  • Frequency 50-60Hz
  • Temperature Off Line at 20 Degree C.
  • Dimensions 600mm x 400mm x 163mm 23.6" x 15.75" x 6.4"
  • Installed Weight 25Kg (55 lb)
  • Enclosure Rating IP 55
  • Operating Humidity 5 - 95% RH (non-condensing)
  • Ambient -40 Degree C to +55 Degree C
  • Operating Temperature Range -40 Degree C to +90 Degree C
  • Current Range 2 to 200 mA
  • Sampling Rate LF for bushing 100kHz HF for PD 100MHz
  • Resolution Current 0.01mA Phase angle 0.01 degree
View Complete Details

Single Channel

Windows based Single / Dual Channel Software-Hardware Charomatography Data processor systems.

Single Channel & Dual Channel



Features


  • Data acquisition of all chromatographs for up to 2 Nos.

  • Multi channel and Multi-Tasking

  • On-line HELP system

  • Use spread-sheet type table for user keyboard input

  • 3D compare or 2D overlay view

  • Zoom in and zoom out on specific data point at any time with mouse

  • Show baseline, retention times, peak start/end, peak top, axis labels

  • Show peak names to verify proper peak identification



GLP Compliant with GUI facility software (Hardware For The Software)



  • 24 Bit A/D Converter at all sampling rates

  • Dynamic range is > 10e6

  • Analog signal Range is from 1.25 VDC

View Complete Details

Inductively Coupled Plasma Mass Spectrometer

10 Lakh - 60 Lakh /Piece Get Latest Price
  • Type inductively coupled plasma mass spectrometer
  • Certification CE Certified, ISO 9001:2008
  • Application Laboratory Use
  • Voltage 220-240V
  • Condition New
  • Display Type Digital
  • Power 2kw
  • Power Source Electric
  • Focal Length 100-200mm
  • Automation Grade Automatic
View Complete Details

Load Buster

  • Application Industrial
  • Nominal Switch Load Current 630 Amperes
  • Maximum Switch Load Current 900 Amperes
  • Nominal Distribution Voltage 14.4/25 kV and 25/34.5 kV
  • Maximum Distribution Voltage 27 kV and 38 kV
View Complete Details

Laboratory TOGA DGA Analyzer


Analyzers for Analysis of Dissolved Gases in Transformer Oil


- Single Injection DGA System TOGA


- Single / Dual injection transformer oil gas analyzers as per IS 10593 / ASTM D 3612 / IEC 60567



Innovative & Advanced Features



  • A fully micro controller GC configured for single injection analysis of transformer oil gas analysis.

  • Totally automated system with FID, TCD and Methanizer controlled through auto timer of GC.

  • Multi column system with automatic gas sampling valve from VICI Valco for column switching, detector switching as well as trap and purge events.

  • Choice for PC control using RS 485 protocol.

  • Can be built using GC Dhruva or GC 2011 or GC 2010 as base module with all features of GC Dhruva, GC 2011 or GC 2010 as standard depending upon the mainframe selected.

  • Various models of TOGA are available as per the budget requirements. variations include single injection, dual injection, single injection with imported valve, single injection with Indian valve, single injection with dual channel DAS system



View Complete Details

Hydrogen Storage Systems


These Hydrogen Storage Systems are imported from abroad and are based on the Rare Earth Metal Alloys (AB5) which are used to store Hydrogen in the form of Metal Hydride. The hydrogen safe storage system keeps the Hydrogen chemically bonded in the Metal Hydride, thus even gunshot strike and engulfing it a burning environment will not result in explosion reaction. Even if there is any leakage occurring in the outer tube, this storage will release Hydrogen very slowly in many hours, hence, any risk of explosion is removed.The Hydrogen storage cum purifier is very convenient to use as it can function at normal room temperature & normal pressures without any additional power supply for its functioning. These systems require no maintenance & can be recharged for over 3000 times which is equivalent to a life span of over 30 years.


These Hydrogen Storage & Purification Systems can be very useful for high precision Chromatography, On-line (Portable) GC, GC-Mass Spectrometry, VOC, THC Station & Laboratories where high purity hydrogen is required.


As the systems weigh only around 0.2 7-kg they are highly transportable and can be placed at most unlikely locations. Besides the above applications these systems can be utilized for strategic applications in various sectors for storage of gases as well as portable gas supply systems in the field areas.


View Complete Details

Dissolved Gas Analyzer DGA System

Economical micro processor based two injection, three injection and four injection dissolved gas analyzer (DGA) system as per IS-10593 and IS-9434.

View Complete Details

Oxygen Nitrogen Determinator

  • Sample weight range 0.1 – 5 grams
  • Nominal sample weight 1 gram.
  • Range of Oxygen detection 1-2000 ppm at 1 gram sample.
  • Range of Nitrogen detection 1-2000 ppm at 1 gram sample.
  • Accuracy for Oxygen ± 2% FSD of O2 present
  • Accuracy for Nitrogen ± 2% FSD of N2 present
  • Precision < 1% RSD of the reading(Doser).
  • Sensitivity for Oxygen& Nitrogen ±1 ppm (Doser)
  • Detection method for Nitrogen gas Thermal Conductivity method.
  • Detection method for Oxygen gas Infrared cell / TC Cell
  • Calibration for Oxygen & Nitrogen Gas dose method & using Cal. Stds.
  • Principle of determination Inert gas fusion.
  • Operation & data processing Microprocessor & computer controlled
  • Sample loading system Inbuilt with provision for automatic Cleaning and maintenance.
The Determinator is capable of Nitrogen & Oxygen determination with great simplicity using latest technology and menu driven software. The operation of the analyzer is simplified with the use of Touch Screen based control systems which make the programming of all functions of the determinator extremely simple. Oxygen Nitrogen Determinator use two or single Detector system at a very high sensitivity Macro Thermal Conductivity Detector &/or Infra red detector capable to detect from 1 ppm to 2000 ppm using a nominal sample size of 1 gram for Oxygen and 1 ppm to 2000 ppm for Nitrogen using nominal weight of 1 gram.



Innovative & Advanced Features


  • Compact and Modular design for ease in operation & Maintenance.

  • It has a large " VGA Touch Screen for the complete control of the system. There is no keypad or other controls visible on the front panel as the complete operation is through the touch screen panel including / excluding current setting for out gas and analyze mode. The complete system is under mod bus RTU protocol for connectivity through other SCADA & supervisory systems.

  • Data acquisition is through software using a PC system so that unlimited files can be stored.

  • All the timers are user settable (Via Supervisory password) thereby making the instrument ideal for routine analysis as well as R & D application. The timers for all the modes are set using the touch screen as well as through the H PPC Determinator control software.

  • On line display of the current mode in progress as well as the time left for mode completion displayed on the touch screen.

  • On line fault diagnosis and stepwise guidance for any fault condition on the Touch Screen console.

  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.

  • Three stage flow control system to prevent accidental change of values.

  • Alarms and safety interlocks.

  • Closed loop coolant circulatory (Optional).

  • Furnace is Glove Box adaptable(Optional).




View Complete Details

Xenon Krypton Determinator

  • Sample weight range :
  • 0.50 to 5.00 grams Nominal sample weight
  • : 1 gram.
  • Range of Xe detection :
  • 1-5000 ppm at 1 gram sample. Range of Kr detection
  • : 1-5000 ppm at 1 gram sample.
  • Accuracy for Xe / Kr :
  • < 2% of the reading Precision
  • : < 1% RSD of the reading.
  • Sensitivity for Xe / Kr :
  • ±1 ppm Detection method for Xe
  • : Thermal Conductivity method.
  • Detection method for Kr :
  • Thermal Conductivity method. Principle of determination
  • : Inert gas fusion.
  • Operation & data processing :
  • Microprocessor & computer controlled Sample loading system
  • : Inbuilt with provision for automatic Cleaning and maintenance.




Xenon Krypton Determinator



XENON-KRYPTON DETERMINATORS have been designed for normal sample size as well as for large diameter sample size of 20 mm (To be specified in advance).

This Determinator is different than the Oxygen-Nitrogen and Hydrogen Determinators as here Xe and Kr are trapped at -60C, and absorbed at 400C, with temperature span of 460C covered within 4 8 seconds.







Xenon Krypton Determinator

XENON-KRYPTON DETERMINATORS have been designed for normal sample size as well as for large diameter sample size of 20 mm (To be specified in advance).

This Determinator is different than the Oxygen-Nitrogen and Hydrogen Determinators as here Xe and Kr are trapped at -60C, and absorbed at 400C, with temperature span of 460C covered within 4 8 seconds.

















Xenon Krypton Determinator





Innovative & Advanced Features


  • Compact and Modular design for ease in operation & Maintenance.

  • It has a large " VGA Touch Screen for the complete control of the system. There is no keypad or other controls visible on the front panel as the complete operation is through the touch screen panel including / excluding current setting for out gas and analyze mode. The complete system is under modulus RTU protocol for connectivity through other SCADA & supervisory systems.Data acquisition is through software using a PC system so that unlimited files can be stored.

  • All the timers are user settable (Via Supervisory password) thereby making the instrument ideal for routine analysis as well as R & D application. The timers for all the modes are set using the touch screen as well as through the H PPC Determinator control software.

  • On line display of the current mode in progress as well as the time left for mode completion displayed on the touch screen.

  • On line fault diagnosis and stepwise guidance for any fault condition on the Touch Screen console.

  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.

  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.

  • Three stage flow control system to prevent accidental change of values.

  • Alarms and safety interlocks.

  • Closed loop coolant circulator(Optional).

  • Furnace is Glove Box adaptable(Optional)

View Complete Details

Sulphur Determinator

The Carbon Sulphur analyzer body is designed of module integration idea. Power supply system composes twin modules which are dust-preventive, simple and reliable; connection cables use flat wire connectors instead of old slot mode which can upgrades whole circuit reliability.
View Complete Details

Carbon Determinator

The Carbon Sulphur analyzer body is designed of module integration idea. Power supply system composes twin modules which are dust-preventive, simple and reliable; connection cables use flat wire connectors instead of old slot mode which can upgrades whole circuit reliability.
View Complete Details

Gas Generators

1.50 Lakh /Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • company specification company specification
Chromatography & instruments co., (cic) baroda, established in 1972 is one of the biggest companies in india involved in the manufacturing of analytical and process systems in india related to chromatography

looking into the problems associated with using gas cylinders in terms of administrative cost, purity and availability and also repeated demand from our users we have started manufacturing gas generators for all types of lab applications.

it has been three years now since we last introduced our gas generators in the indian market and these three years have seen not only our market share growing substantially but also some very advanced features incorporated in the systems for instrumentation users. presently we are having over 180 generators in market.

being pioneers in the field of gas chromatography & on line gc systems in india we take utmost care during the manufacturing and testing of the gas generators as we are aware what havoc can be caused to the detectors and columns when purity of the gas is compromised. Moreover, being instrumentation people we have designed the system to give you a system that requires little or no maintenance for years together.

If you do not see a system meeting your requirements, please do not hesitate to contact us as we also undertake manufacturing of custom built systems. We look forward to hear from you for your requirements and work together in the near future.

Additional Information:

Payment Terms : L/C

Packaging Details : Export Packing

Delivery Time : 2-3 Months

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gaurav Shingari (Chromatography and Instruments Company.)
  • 121-122, GIDC, Makarpura Industrial Estate, Vadodara, Gujarat - 390 010 - 390010
  • Share us via
  • Call 08068051328 Ext. 253
List of Other Products by Chromatography and Instruments Company. from Vadodara, Gujarat.
Post Buy Requirement
Chromatography and Instruments Company.
Vadodara, Gujarat, India
Verified Add Review

Other Products / Services #1397586

Oxygen Nitrogen Determinator

  • Model Number TS-ON
  • Brand Name CIC
  • Application Steel and Steel Alloy Analysis, Refractory Metal Analysis, Ceramics, Superconductors, Rare Earths
  • Type Oxygen Nitrogen Determinator
  • Power Supply 230 V AC
  • Features Data acquisition is through software using a PC system so that unlimited files can be stored
  • Color Grey
  • Automation Grade Automatic
  • Usage Area Diffusible Hydrogen Analyzer, Analysis of Non Metals, Analysis of Weld Metal, Molten Metal Analysis
  • Operating Temperature Range +18 Degree C to 24 Degree C
  • Line Voltage 230 VAC 50 Hz
  • Line Power 900 Watts
  • Water Reservoir Capacity 30+ Litres
  • Water Quality Bi- Distilled
View Complete Details

Elemental Analyzer

  • Color Grey
  • Country of Origin Made in India
  • Area Usage Copper and Copper Alloy, Nickel and Nickel Alloy, Analysis of Inorganic Materials
  • Model Name/Number H-TS
  • Usage/Application Steel and Steel Alloy Analysis, Refractory Metal Analysis, Ceramics, Superconductors, Rare Earths
  • Detector Type FID/TCD/Micro TCD/PDHID/ECD
  • Display Type It has a large 1/4
  • Water Quality Bi-Distilled
  • Operating Temperature +18 Degree C to 24 Degree C
  • Line Voltage 230 VAC 50 Hz
  • Line Power 900 Watts
View Complete Details

Carbon Sulphur Analyzer

  • Country of Origin Made in India
  • Area Usage UO2/MOX analysis, Steels and Ferro Alloys analysis, Aluminium and Aluminium Alloy Analysis
  • Model Name/Number CS-TS
  • Machine Type Automatic
  • Usage/Application Steel and Steel Alloy Analysis, Refractory Metal Analysis, Ceramics, Superconductors, Rare Earths
  • Brand Name CIC
  • Color Grey, Blue
  • Frequency 50 Hz
  • Electronic balance Upto 100 mg with 1 mg resolution
View Complete Details

Micro Gas Chromatograph System

  • Brand Name CIC
  • Application Laboratory Use
  • Weight Approx. 16 Kg
  • Automation Grade Automatic
  • Frequency 50 Hz
  • Voltage 230 V
  • Material Mild Steel
  • Power 4 Amperes
  • Color Grey
  • Country of Origin Made in India
  • Application Area Gases with sulphur group, Corrosive and Miscellaneous gases, Lower hydrocarbons, Phenols, Steroids
  • Display Inch 1/4 inch VGA Display
  • Temperature Zone Ambient to 220 Degree C
  • No. Of Detector Can be coupled with up to 2 detectors
View Complete Details

Hydrogen Gas Generator

  • Weight 7 Kgs To 200 Kgs
  • Country of Origin Made in India
  • Purity 99.995%to 99.999%
  • Application Area Light gases - Permanent Gases, Gases containing carbon group, Gases containing halogen group, Amines
  • Frequency 50 Hz
  • Generator Type Three Phase
  • Usage/Application Hydrogen Generator
  • Grade Standard Industrial Grade
  • Brand/Make CIC
  • Product Type Hydrogen Gas Generator
  • Start Up Time 15 minutes
  • Power Supply 230V AC
  • Noise <42 dB-60 dB model dependent
  • Oxygen <3ppm-1ppm
  • Water dew point -40 DegreeC
  • Outflow Speed Model Dependent
  • Outflow Pressure 60 PSIG
  • Pressure Stability <0.001 MPa
  • Flow Control & Display Accuracy +/- 5% of FSD using digital MFC system
  • Alarms Low water level, Gas leakage, Excess pressure & Low pressure
  • Rated Voltage 220 V +- 10% ; 50 Hz
  • Rated Power 200 W to 400 W dependent on model
  • Temperature 18 - 25 Degree C
  • Compressor In build in the system or external model dependent
View Complete Details

Online Partial Discharge Monitoring System

  • Voltage 100-240 V
  • Features Comprehensive monitoring of transformer bushings and PD activity on a 3 phase transformer or a bank
  • Brand Name GE Kelman
  • Usage/Application Industrial Use
  • Model Name/Number Intellix BMT 330
  • Automation Grade Automatic
  • Frequency 50-60Hz
  • Temperature Off Line at 20 Degree C.
  • Dimensions 600mm x 400mm x 163mm 23.6" x 15.75" x 6.4"
  • Installed Weight 25Kg (55 lb)
  • Enclosure Rating IP 55
  • Operating Humidity 5 - 95% RH (non-condensing)
  • Ambient -40 Degree C to +55 Degree C
  • Operating Temperature Range -40 Degree C to +90 Degree C
  • Current Range 2 to 200 mA
  • Sampling Rate LF for bushing 100kHz HF for PD 100MHz
  • Resolution Current 0.01mA Phase angle 0.01 degree
View Complete Details

Single Channel

Windows based Single / Dual Channel Software-Hardware Charomatography Data processor systems.

Single Channel & Dual Channel

Features
  • Data acquisition of all chromatographs for up to 2 Nos.
  • Multi channel and Multi-Tasking
  • On-line HELP system
  • Use spread-sheet type table for user keyboard input
  • 3D compare or 2D overlay view
  • Zoom in and zoom out on specific data point at any time with mouse
  • Show baseline, retention times, peak start/end, peak top, axis labels
  • Show peak names to verify proper peak identification

GLP Compliant with GUI facility software (Hardware For The Software)

  • 24 Bit A/D Converter at all sampling rates
  • Dynamic range is > 10e6
  • Analog signal Range is from 1.25 VDC
View Complete Details

Inductively Coupled Plasma Mass Spectrometer

10 Lakh - 60 Lakh /Piece Get Latest Price
  • Type inductively coupled plasma mass spectrometer
  • Certification CE Certified, ISO 9001:2008
  • Application Laboratory Use
  • Voltage 220-240V
  • Condition New
  • Display Type Digital
  • Power 2kw
  • Power Source Electric
  • Focal Length 100-200mm
  • Automation Grade Automatic
View Complete Details

Load Buster

  • Application Industrial
  • Nominal Switch Load Current 630 Amperes
  • Maximum Switch Load Current 900 Amperes
  • Nominal Distribution Voltage 14.4/25 kV and 25/34.5 kV
  • Maximum Distribution Voltage 27 kV and 38 kV
View Complete Details

Laboratory TOGA DGA Analyzer

Analyzers for Analysis of Dissolved Gases in Transformer Oil

- Single Injection DGA System TOGA

- Single / Dual injection transformer oil gas analyzers as per IS 10593 / ASTM D 3612 / IEC 60567

Innovative & Advanced Features
  • A fully micro controller GC configured for single injection analysis of transformer oil gas analysis.
  • Totally automated system with FID, TCD and Methanizer controlled through auto timer of GC.
  • Multi column system with automatic gas sampling valve from VICI Valco for column switching, detector switching as well as trap and purge events.
  • Choice for PC control using RS 485 protocol.
  • Can be built using GC Dhruva or GC 2011 or GC 2010 as base module with all features of GC Dhruva, GC 2011 or GC 2010 as standard depending upon the mainframe selected.
  • Various models of TOGA are available as per the budget requirements. variations include single injection, dual injection, single injection with imported valve, single injection with Indian valve, single injection with dual channel DAS system
View Complete Details

Hydrogen Storage Systems

These Hydrogen Storage Systems are imported from abroad and are based on the Rare Earth Metal Alloys (AB5) which are used to store Hydrogen in the form of Metal Hydride. The hydrogen safe storage system keeps the Hydrogen chemically bonded in the Metal Hydride, thus even gunshot strike and engulfing it a burning environment will not result in explosion reaction. Even if there is any leakage occurring in the outer tube, this storage will release Hydrogen very slowly in many hours, hence, any risk of explosion is removed.The Hydrogen storage cum purifier is very convenient to use as it can function at normal room temperature & normal pressures without any additional power supply for its functioning. These systems require no maintenance & can be recharged for over 3000 times which is equivalent to a life span of over 30 years.

These Hydrogen Storage & Purification Systems can be very useful for high precision Chromatography, On-line (Portable) GC, GC-Mass Spectrometry, VOC, THC Station & Laboratories where high purity hydrogen is required.

As the systems weigh only around 0.2 7-kg they are highly transportable and can be placed at most unlikely locations. Besides the above applications these systems can be utilized for strategic applications in various sectors for storage of gases as well as portable gas supply systems in the field areas.

View Complete Details

Dissolved Gas Analyzer DGA System

Economical micro processor based two injection, three injection and four injection dissolved gas analyzer (DGA) system as per IS-10593 and IS-9434.

View Complete Details

Oxygen Nitrogen Determinator

  • Sample weight range 0.1 – 5 grams
  • Nominal sample weight 1 gram.
  • Range of Oxygen detection 1-2000 ppm at 1 gram sample.
  • Range of Nitrogen detection 1-2000 ppm at 1 gram sample.
  • Accuracy for Oxygen ± 2% FSD of O2 present
  • Accuracy for Nitrogen ± 2% FSD of N2 present
  • Precision < 1% RSD of the reading(Doser).
  • Sensitivity for Oxygen& Nitrogen ±1 ppm (Doser)
  • Detection method for Nitrogen gas Thermal Conductivity method.
  • Detection method for Oxygen gas Infrared cell / TC Cell
  • Calibration for Oxygen & Nitrogen Gas dose method & using Cal. Stds.
  • Principle of determination Inert gas fusion.
  • Operation & data processing Microprocessor & computer controlled
  • Sample loading system Inbuilt with provision for automatic Cleaning and maintenance.
The Determinator is capable of Nitrogen & Oxygen determination with great simplicity using latest technology and menu driven software. The operation of the analyzer is simplified with the use of Touch Screen based control systems which make the programming of all functions of the determinator extremely simple. Oxygen Nitrogen Determinator use two or single Detector system at a very high sensitivity Macro Thermal Conductivity Detector &/or Infra red detector capable to detect from 1 ppm to 2000 ppm using a nominal sample size of 1 gram for Oxygen and 1 ppm to 2000 ppm for Nitrogen using nominal weight of 1 gram.
Innovative & Advanced Features
  • Compact and Modular design for ease in operation & Maintenance.
  • It has a large " VGA Touch Screen for the complete control of the system. There is no keypad or other controls visible on the front panel as the complete operation is through the touch screen panel including / excluding current setting for out gas and analyze mode. The complete system is under mod bus RTU protocol for connectivity through other SCADA & supervisory systems.
  • Data acquisition is through software using a PC system so that unlimited files can be stored.
  • All the timers are user settable (Via Supervisory password) thereby making the instrument ideal for routine analysis as well as R & D application. The timers for all the modes are set using the touch screen as well as through the H PPC Determinator control software.
  • On line display of the current mode in progress as well as the time left for mode completion displayed on the touch screen.
  • On line fault diagnosis and stepwise guidance for any fault condition on the Touch Screen console.
  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.
  • Three stage flow control system to prevent accidental change of values.
  • Alarms and safety interlocks.
  • Closed loop coolant circulatory (Optional).
  • Furnace is Glove Box adaptable(Optional).

View Complete Details

Xenon Krypton Determinator

  • Sample weight range :
  • 0.50 to 5.00 grams Nominal sample weight
  • : 1 gram.
  • Range of Xe detection :
  • 1-5000 ppm at 1 gram sample. Range of Kr detection
  • : 1-5000 ppm at 1 gram sample.
  • Accuracy for Xe / Kr :
  • < 2% of the reading Precision
  • : < 1% RSD of the reading.
  • Sensitivity for Xe / Kr :
  • ±1 ppm Detection method for Xe
  • : Thermal Conductivity method.
  • Detection method for Kr :
  • Thermal Conductivity method. Principle of determination
  • : Inert gas fusion.
  • Operation & data processing :
  • Microprocessor & computer controlled Sample loading system
  • : Inbuilt with provision for automatic Cleaning and maintenance.

Xenon Krypton Determinator

XENON-KRYPTON DETERMINATORS have been designed for normal sample size as well as for large diameter sample size of 20 mm (To be specified in advance).

This Determinator is different than the Oxygen-Nitrogen and Hydrogen Determinators as here Xe and Kr are trapped at -60C, and absorbed at 400C, with temperature span of 460C covered within 4 8 seconds.

Xenon Krypton Determinator
XENON-KRYPTON DETERMINATORS have been designed for normal sample size as well as for large diameter sample size of 20 mm (To be specified in advance).

This Determinator is different than the Oxygen-Nitrogen and Hydrogen Determinators as here Xe and Kr are trapped at -60C, and absorbed at 400C, with temperature span of 460C covered within 4 8 seconds.

Xenon Krypton Determinator
Innovative & Advanced Features
  • Compact and Modular design for ease in operation & Maintenance.
  • It has a large " VGA Touch Screen for the complete control of the system. There is no keypad or other controls visible on the front panel as the complete operation is through the touch screen panel including / excluding current setting for out gas and analyze mode. The complete system is under modulus RTU protocol for connectivity through other SCADA & supervisory systems.Data acquisition is through software using a PC system so that unlimited files can be stored.
  • All the timers are user settable (Via Supervisory password) thereby making the instrument ideal for routine analysis as well as R & D application. The timers for all the modes are set using the touch screen as well as through the H PPC Determinator control software.
  • On line display of the current mode in progress as well as the time left for mode completion displayed on the touch screen.
  • On line fault diagnosis and stepwise guidance for any fault condition on the Touch Screen console.
  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.
  • On line Manual, On line Method Development and On line Fault Diagnosis software in case the H PPC Determinator control software is procured.
  • Three stage flow control system to prevent accidental change of values.
  • Alarms and safety interlocks.
  • Closed loop coolant circulator(Optional).
  • Furnace is Glove Box adaptable(Optional)
View Complete Details

Sulphur Determinator

The Carbon Sulphur analyzer body is designed of module integration idea. Power supply system composes twin modules which are dust-preventive, simple and reliable; connection cables use flat wire connectors instead of old slot mode which can upgrades whole circuit reliability.
View Complete Details

Carbon Determinator

The Carbon Sulphur analyzer body is designed of module integration idea. Power supply system composes twin modules which are dust-preventive, simple and reliable; connection cables use flat wire connectors instead of old slot mode which can upgrades whole circuit reliability.
View Complete Details

Gas Generators

1.50 Lakh /Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • company specification company specification
Chromatography & instruments co., (cic) baroda, established in 1972 is one of the biggest companies in india involved in the manufacturing of analytical and process systems in india related to chromatography looking into the problems associated with using gas cylinders in terms of administrative cost, purity and availability and also repeated demand from our users we have started manufacturing gas generators for all types of lab applications. it has been three years now since we last introduced our gas generators in the indian market and these three years have seen not only our market share growing substantially but also some very advanced features incorporated in the systems for instrumentation users. presently we are having over 180 generators in market. being pioneers in the field of gas chromatography & on line gc systems in india we take utmost care during the manufacturing and testing of the gas generators as we are aware what havoc can be caused to the detectors and columns when purity of the gas is compromised. Moreover, being instrumentation people we have designed the system to give you a system that requires little or no maintenance for years together. If you do not see a system meeting your requirements, please do not hesitate to contact us as we also undertake manufacturing of custom built systems. We look forward to hear from you for your requirements and work together in the near future.

Additional Information:

Payment Terms : L/C

Packaging Details : Export Packing

Delivery Time : 2-3 Months

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gaurav Shingari (Chromatography and Instruments Company.)
  • 121-122, GIDC, Makarpura Industrial Estate, Vadodara, Gujarat - 390 010 - 390010