Physical Properties Formula C4H10 Molecular Weight 58.13 Boiling Point a(°C) -11.7 Critical Temperature, °C 135 Critical Pressure, Mpa 3.65 Critical Density, gm³ 0.221 Density of saturated liquid 25°C, gm³ 0.551 Specific heat of liquid, 25°C, [KJ(KG·°C)] 2.38 Latent heat of evaporation at atm pressure, KJKG 362.6 ODP(CFC-11=1.0) 0 GWP(CO2=1.0) 1320

Hybridm MAPP gas is the new generation of MAPP gas. 1. The heater warms faster than MAPP gas. 2. It can reach a higher combustion temperature (Max. 1300°C) than MAPP gas under anaerobic conditions. 3. Leaves no reside or deposits after combustion. 4. Operates normally even when outside temperature is very low and iced over. (Minimum Temperature: -20°C) Ingredients Information Ingredients% Volume Propylene CAS NO. 115-07-1 56.0 Methyl Acetylene-Propadiene CAS NO. 56960-91-9 44.0 Physical & Chemical Property Physical StateBoiling PointFreezing PointSpecific Gravity (H20 =1)Vapor Pressure (mm Hg) @ 70 °FVapor Density (Air = 1)Evaporation Rate Butyl Acetate -1)Solubility in WaterAppearance and Odor Gas -54 to -10 °F -48 to -23 °C -184°F -120°C 0.571 135 Psig 1.48 NA Slight A colorless gas with a characteristic, unpleasant odor. Packaging & Storage MAPP gas is available in disposable steel cylinder (Size: �75�280mm; Net Weight: 16oz). The standard packages are as follow: 12 cylinders per carton; 17004 cylinders per 20ft container. Store in cool, dry, well-ventilated area away from heavily trafficked areas and emergency exits. Do not allow the temperature where cylinders are stored to exceed 125°F (52°C). Cylinders should be stored upright and firmly secured to prevent falling or being knocked over. Full and empty cylinders should be segregated. Use a "first in-first out" inventory system to prevent full cylinders from being stored for excessive periods of time. Post "NO SMOKING OR OPEN FLAMES" signs in the storage or use area. There should be no sources of ignition in the storage or use area. This fuel gas should not be handled or used in metals that form acetylides, such as copper, silver, magnesium or their alloys.








Share your thoughts with other customers for Hybridm
Add Review