Our Products
We offer the best product range of 600V Cable XHHW-2 Type Aluminum Conductors, RHH or RHW-2 or USE-2 aluminum conductors, SER/SEU Cables, YJLHS Cables and YJLHV Cables.
aluminum alloy ul csa standard
description
voltage
600v or less
construction
rhh or rhw-2 or use-2 aluminum conductors are aa-8000 series aluminum alloy, compact stranded. Insulation is an abrasion, moisture, heat, and sunlight resistant black cross-linked polyethylene (xlp).
copper conductor is also available.
standard
rhh or rhw-2 or use-2 conductors meet or exceed ul standard 44 (for rhh or rhw-2), ul standard 854(for use-2), federal specification a-a-59544, and requirements of the nec. Or other standards required by customers.
features
1.-40----90
2.abrasion, high-heat and moisture and sunlight resistant.
3.vw-1 or higher required by ul.
applications
1. Rhh or rhw-2 or use-2 conductors are used with conduit as specified in the nec.
2. May also be used as underground service entrance cable, for direct burial, at conductor temperatures not to exceed 90.
3. When used as rhh, conductor temperatures shall not exceed 90 in dry locations.
4. When used as rhw-2 or use-2, conductor temperatures shall not exceed 90 in wet or dry locations.
package
steel wooden reel, wooden reel, steel reel, in coils on wooden tray, or other requirements by customers.
description
voltage
600v or less
construction
sino-cables xhhw-2 type aluminum conductors are annealed aa-8000 series aluminum alloy, compact stranded. Insulation is an abrasion, moisture and high-heat resistant black cross-linked polyethylene. Conductor sizes awg 2 and larger listed and marked sunlight resistant in black only.
copper conductor is also available.
standard
xhhw-2 conductors meet or exceed ul standard 44 .federal specification a-a-59544, and requirements of the nec type xhhw-2 meets and exceeds all construction requirements of icea s-95-658(nema wc 70)-non shielded 0-2kv cables, with testing frequencies based on ul requirements.
features
1.-40----90
2.high-heat and moisture and sunlight resistant.
3.vw-1 or higher required by ul.
applications
1.xhhw-2 conductors are primarily used in conduit or recognized raceways for services, feeders, and branch circuit wiring as specified in the national electric code(nec).
2.may also be used in wet or dry locations at temperatures not to exceed 90.
3.voltage rating for rw90 cable is 600v.
package
steel wooden reel, wooden reel, steel reel, in coils on wooden tray, or other requirements by customers.
| w e I g h t s. m e a s u r e m e n t s | ||||||
| conductor size | insulation | nominal o.d. | allowable | approximate | ||
| 60 | 75 | 90 | ||||