My ExportersIndia

For Buyer

For Seller

For Help

Our Products

Our Complete range of products are AHU - Air Handling Unit Components, Vertical Laminar Air Flow Bench, RLAF Reverse Laminar Airflow Bench and Horizontal Laminar Airflow Bench.

RLAF Reverse Laminar Airflow Bench

  • Power Supply 230 V AC 1-Ø 50HZ
  • Vibration Level : Minimum
  • Noise Level : Less than 65 dB when Ambient is not greater than 55 dB

CRESCENDO makeReverse Laminar Airflow Benchfinds a major application in sampling and dispensing. Majorly used for mixed airflow stream to control the hazardous emission of dust powder during dispensing or sampling process.

Dust air particles are being filtered and clean air stream is provided in the zone of exposed product and the operator breathing zone. The RLAF is designed to provide Class 100 working environment at rest with built in scavenging system to ensure product, operator as well as surrounding environment protection.

Technical Details
  • SS 304 / CRCA powder coated construction except Filters and motor-blower assemblies which will be in standard execution.
  • Minipleat HEPA Filter with hot melt technology, which conforms to EU 13 Grade, with an efficiency rating better than 99.99% for 0.3 at exhaust position.
  • Prefilter, which conforms to EU 4 Grade, with efficiency of 90% down to 10 micron. These Filters are basically made from micro-Fibre-glass washable media.
  • Intermediate filters which conform to EU 7 Grade, with efficiency of 95% down to 3 micron. These Filters are basically made from micro-Fibre-glass media and are inherently washable.
  • Motor Blower provided are statically and dynamically balanced to supply air flow with sufficient capacity and static pressure for entire life of HEPA. Blower is high performance, noise abated and light weighted.
  • SS 304 Double Walled Side Panels.
  • Magnehelic Differential Pressure Gauges (0 - 25 mm) to monitor pressure drop across intermediate filter & HEPA filter; and (0-10mm) to monitor pressure drop across Prefilter with respect to ambient.
  • Fluorescent Light (250 Lux)
  • ON/OFF Switches for motor & lights
  • Electrical control panel mounted on the side panel of the unit.
  • 5/15 Amp single-phase switch socket for external equipment.
  • DOP Test port at upstream of HEPA filter to personnel for carrying out the HEPA Filter Integrity Test.
Site Requirements
  • Client to ensure that floor is properly leveled; so that the equipment is installed with covings flush with the floor to avoid any gap.
  • The unit will be provided with 3 mtr. Long cable. In case of wall mounted or remotely located control panel, provision of any electrical cabling required from unit to control panel & control panel to the ON / OFF switch will be in Client's scope.
  • Client to confirm the location of supply pendant to enable us to decide on the entry of main cable in the unit to avoid any loose from projecting out.
  • Concealing of electrical cabling (if so required ) is in Client's scope.
  • Any electrical cabling required between control panel to the supply point is in Client's scope.
  • Client to provide facility of 20 psig compressed air / nitrogen cylinder any compressed gas not harmful to personnel for carrying out the HEPA Filter Integrity Test.
Test Carried Out At Site
  • HEPA Filter Integrity Test
  • Particle Count Test
  • Air Velocity Measurement Test
  • Smoke Profile Test (Video Shooting/ Photography to be arranged by client )
Performance

Air cleanliness : ISO Class 5

Air Velocities : 90 10 FPM

Air Flow : Vertical - Recirculatory

Noise Level : Less than 65 dB when Ambient is not greater than 55 dB

Vibration Level : Minimum

Power Supply : 230 V AC 1- 50HZ

View Complete Details

Vertical Laminar Air Flow Bench

  • Power Supply : 230 V AC 1-Ø 50HZ
  • Vibration Level : Minimum
  • Air Flow : Vertical
  • Air Velocities : 90 ± 10 FPM

CRESCENDO make Vertical Laminar Airflow Benches are designed to provide Class 100 workstations for creation of a bacterial dust free air space.

VLAFs are used for work with low risk substances and materials, when protection of working material from environment is necessary or the item requires a sterile working zone.

Technical Details
  • SS 304 / CRCA powder coated construction except filters and motor-blower assemblies which will be in standard execution.
  • Conventional Hepa Filter for supply which conforms to EU 12 Grade with an efficiency rating better than 99.97% for 0.3 . Also, Minipleat HEPA Filter with hot melt technology, which conforms to EU 13 Grade, with an efficiency rating better than 99.99% for 0.3 at supply position can be used.
  • Primary pre filter for suction, which conforms to EU 6 Grade, with efficiency of 95% down to 5 micron. These Filters are basically made from micro-Fibre-glass washable media.
  • Motor, Blower provided are statically and dynamically balanced to supply air flow with sufficient capacity and static pressure for entire life of HEPA. Blower is high performance, noise abated and light weighted.
  • Magnehelic Differential Pressure Gauge (0 - 25 mm or 0-50 mm) to monitor pressure drop across HEPA Filter with respect to ambient.
  • Fluorescent Light (250 Lux)
  • ON/OFF Switches for motor & lights.
  • 5/15 Amp single-phase switch socket for external equipment
  • DOP Test port at upstream of HEPA filter
  • Soft wall curtain to make Laminar Airflow direct on the work table
Site Requirements
  • Client to provide layout drawings (with respect to unit location) with dimensional details to enable us to work out exact dimensions of the Laminar Flow Unit. Also following details will be required to enable us to calculate length of ceiling suspension members & Polycarbonate / Equivalentside panels :Floor to Main Ceiling heightFloor to False Ceiling heightFloor to work table height
  • Client to confirm the preferred location of the Control Panel and ON/OFF switch.
  • In case of wall mounted or remotely located control panel, provision of any electrical cabling required from unit to control panel & control panel to the ON/OFF switch will be in Client scope.
  • Client to confirm the location of supply pendant to enable us to decide on the entry of main cable in the unit to avoid any loose from projecting out.
  • Concealing of electrical cabling (if required ) is in Client's scope.
  • Client to provide facility of 20 psig compressed air / nitrogen cylinder any compressed gas not harmful to personnel for carrying out the HEPA Filter Integrity Test.
Test Carried Out At Site
  • HEPA Filter Integrity Test
  • Particle Count Test
  • Air Velocity Measurement Test
  • Smoke Profile Test (Video Shooting/ Photography to be arranged by client )
Performance

Air cleanliness : ISO Class 5

Air Velocities : 90 10 FPM

Air Flow : Vertical

Noise Level : Less than 65 dB when Ambient is not greater than 55 dB

Vibration Level : Minimum

Power Supply : 230 V AC 1- 50HZ

View Complete Details

Horizontal Laminar Airflow Bench

  • Power Supply : 230 V AC 1-Ø 50HZ
  • Vibration Level : Minimum
  • Noise Level : Less than 65 dB when Ambient is not greater than 55 dB
  • Air Flow : Horizontal
Horizontal Laminar Airflow Bench (HLAF)

CRESCENDO make Horizontal Laminar Airflow Benches are designed to provide Class 100 workstations for creation of a bacterial dust free air space.

HLAFs are used for work with low risk substances and materials, when protection of working material from environment is necessary or the item requires a sterile working zone.


Technical Details
  • SS 304 / CRCA powder coated construction except Filters and motor-blower assemblies which will be in standard execution.
  • Conventional Hepa Filter for supply which confirms to EU 12 Grade with an efficiency rating better than 99.97% for 0.3 . Also, Minipleat HEPA Filter with hot melt technology, which conforms to EU 13 Grade, with an efficiency rating better than 99.99% for 0.3 at supply position can be used.
  • Primary Pre filters for suction which confirms to EU 6 Grade with an efficiency rating better than 95% down to 5 made from micro fiber glass washable media.
  • Motor, Blower provided are statically and dynamically balanced to supply air flow with sufficient capacity and static pressure for entire life of HEPA. Blower is high performance, noise abated and light weighted.
  • Magnehelic Differential Pressure Gauge (0 - 25 mm or 0-50 mm) to monitor pressure drop across HEPA Filter.
  • Provision for Gas cock and Vacuum cock as per requirement.
  • Fluorescent Light (250 Lux).
  • ON/OFF Switches for motor & lights.
  • 5/15 Amp single-phase switch socket for external equipment.
  • DOP Test port at upstream of HEPA filter. Hour Meter to personnel fr carrying out the HEPA Filter Integrity Test.
Site Requirements
  • Client to ensure that floor is properly leveled; so that the equipment is installed with covings flush with the floor to avoid any gap.
  • The unit will be provided with 3 mtr. Long cable. In case of wall mounted or remotely located control panel, provision of any electrical cabling required from unit to control panel & control panel to the ON / OFF switch will be in Client's scope.
  • Client to confirm the location of supply pendant to enable us to decide on the entry of main cable in the unit to avoid any loose from projecting out.
  • Concealing of electrical cabling (if so required ) is in Client's scope.
  • Client to provide facility of 20 psig compressed air / nitrogen cylinder any compressed gas not harmful to personnel for carrying out the HEPA Filter Integrity Test.
Test Carried Out At Site
  • HEPA Filter Integrity Test
  • Particle Count Test
  • Air Velocity Measurement Test
  • Smoke Profile Test (Video Shooting/ Photography to be arranged by client )
Performance

Air cleanliness : ISO Class 5

Air Velocities : 90 10 FPM

Air Flow : Horizontal

Noise Level : Less than 65 dB when Ambient is not greater than 55 dB

Vibration Level : Minimum

Power Supply : 230 V AC 1- 50HZ

View Complete Details

AHU - Air Handling Unit Components

  • Coils : ARI 410
  • Motors : S-325
  • Filters : BS-6540 / ASHRAE 52-76
Inner Body & Components of the Unit

The highly smooth inner surfaces of the panels along with internal covings, reduces drastically the risk of dirt and bacteria accumulation. There is no erosion of internal insulation material or any welding of the joints to provide an air steam with zero contamination.

Drain Pan (for air-conditiong applications)

The condensate drain pan is fabricated from 0.8 mm / 1 mm thick G.I. / SS304 depending on the application. This wider drain pan with differential slope assures quick and complete water drainage, thus avoiding migration of moisture, which is the major cause of microbiological growth.

Filters

The unit is provided with 10 / 20 micron, easily washable factory manufactured prefilters. These filters are generally confirming to EU-3 of EN-779 specifications.

Also, depending on the requirement, microvee and HEPA filters can also be provided in the unit.

Blower

Usage of imported Kruger/Nicotra make (AMCA certified) blowers along with anti-vibration spring isolators and rubber mountings isolates the fan from the main structure, thus minimizing vibrations and hence low operating noise. The blowers are balanced after complete assembly to G2.5 level.

Fans with the balance grade of G1.0 can be upon request.

Cooling Coil

The staggered tubes, corrugated plate fins and die formed channels form mild ripples of the flowing air, thus providing excellent heat transfer capability with low air side pressure drop.

Mechanical expansion of copper tubes with aluminium fins assures tight bonding to enhance the heat transfer.

Performance Standards

Generally in accordance to :

Fan : AMCA 210

Coils : ARI 410

Motors : S-325

Filters : BS-6540 / ASHRAE 52-76

Other filter sections can also be added depending on the requirement.Specification are subject to change without prior notice.

Double Skin Air Handling Unit Dimensional Details - 25 mm Thk. Panels)
  Air Flow Fan Section - Horizontal & Vertical Discharge Coil Section (1-6 Rows) Droplet Eliminators (2 Rows) Humidification Section with External Pump - 1 Row Nozzle Flat Filter Section (48 mm Thk.) Mixing Box Section - Two Dampers
Model     Sectional Length - mm
cmh cfm            
CA-101 1416 833 909 405 152 1466 152 405
CA-103 3067 1806 962 405 152 1466 152 405
CA-105 5013 2951 1114 405 152 1466 152 557
CA-107 6901 4063 1114 405 152 1466 152 557
                 
CA-111 11059 6510 1409 405 152 1466 152 852
CA-116 16456 9688 1719 405 152 1466 152 852
CA-120 21027 12378 1719 405 152 1466 152 852
CA-125 26453 15573 1871 405 152 1466 152 852
                 
CA-133 33029 19444 2071 405 152 1466 152 1162
CA-142 42113 24792 2166 406 152 1466 152 1466
CA-151 49633 29219 2324 405 152 1466 152 1466
CA-158 57418 33802 2576 405 152 1466 152 1466
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us