Post Buy Requirement
CI
Ahmedabad, Gujarat, India
Add Review

Our Products

  1. Laboratory Shakers 3 Products available
  2. Industrial Machinery 5 Products available
  3. Measuring Instruments & Equipment 4 Products available
  4. Laboratory Apparatus 8 Products available
  5. Lab Instrument 3 Products available
  6. Laboratory Equipments 5 Products available
  7. Others 40 Products available

Other Products / Services #2605016

Riffle Sample Divider

Introduction

U.sed for rapid collection of the true representative sample from aggregate, sand and filters.

Consists of a metal box fitted with a series of chutes of equal width which discharge the material alternatively in opposite directions into separate pans. The chutes of the riffle are steep enough to allow rapid flowing of the material. Each riffle sample divider supplied with two pans and one scoop

Available in following sizes:

Size (mm)13202540No. of Slot14161616

View Complete Details

Buoyancy Balance

Consists of a rigid support frame, incorporating a water tank mounted on a platform. A mechanical lifting device is used to raise the water tank through the frame height immersing the specimen suspended below the balance. The balance supplied may also be used as a standard weighing device, thus providing a versatile and comprehensive weighing system in the laboratory
WEIGHING IN AIR AND IN WATER FRAME : Consisting of a rigid frame, water tank, and cradle.

View Complete Details

Elongation Gauge

Introduction Used to determine the Elongation Index of the Aggregate. Aggregate particles are considered elongated when their length is more than 1.8 of the nominal size. It consists of a hard wood base with vertically mounted metal studs as specified in the IS.
View Complete Details

Jaw Crusher Laboratory

Introduction Laboratory Jaw Crusher is designed to speed up the crushing of aggregate, ores, minerals, coal, coke, chemicals and other similar materials. Its compact and of rugged construction is advantageous for general laboratory or small pilot plant operations.
wo jaws of manganese steel are provided in the jaw crusher. The moveable jaw produces two blows for every revolution, thus reducing over sizing to a minimum. A combination of forward and downward and strokes with a rocking action exerts pressure on the coarse material to pass through the jaws. A hopper is provided at the top for feeding materials. The smooth jaws ensure a uniform product and easy cleaning is possible.
Max Size of feed 50mm (approximately) Product discharge
Size of feed 6mm to 18mm (adjustable)
Capacity 80kG/hr (approximately - based on material)
Operation On 440 volt, 3 Phase, 50hz, A.C. supply with 3H.P.
Electric motor motor, a starter ' v ' belt pulley drive and mounting
View Complete Details

Density Basket

Introduction Used for specific gravity and water absorption test of aggregate. The basket is used in conjunction with a suitable electronic balance, a specially designed robust frame to support the electronic balance and water tight container.
The Density basket is of 20cm dia x 20cm high fitted with galvanized wire mesh of 6.3mm with handle for suspending it from the balance.
Optional Accessories: The following accessories are not part of the standard supply and are supplied at an extra cost.
  • Electronic Balance capacity 5 kg x 0.5gm / 5 kg x 0.1 gm with under bench weighing facility.
  • Laboratory Oven.
  • Water tight container.
A specially designed frame with moving platform to carry the water container allowing the test specimens to be weighed in both air and water.
View Complete Details

Flakiness Gauge

Introduction Used to determine the flakiness index of the aggregate. The aggregate particles are to be considered flaky, if their thickness is less than 0.6 of their nominal size.
It consists of a frame with sliding panel with accurate slots of different standard width and length, the complete assembly is chrome plated or powder coated.
View Complete Details

Vertical Autoclave

Introduction: Our vertical autoclaves are widely used for the day to day sterilization procedures and in various laboratory applications.We specialize in both standard and customized models, specifically designed to meet the challenging demands of various scientists for individual and specialized research applications. Apart from that, we are also supplying our economical autoclave in India catering to variety of customers ranging from Defense Installations, Research Laboratories and Educational Institutes and various R&D laboratories of leading national and multinational companies.
View Complete Details

Bottle Washing Machine

Introduction
  • EIE-1805 With Soaking Tank
  • EIE-1805 Fixed Speed
  • EIE-1805 Variable Speed
With Soaking Tank Electrically operated, fitted with H.P. Motor, coupled by means of pulley of two chucks into which different sizes of bushed can be fixed. The speed of motor is approx.450 RPM. An aluminium anodized baffle is placed so that water may not splash. The motor unit is covered by metal guard. The soaking unit is mounted on angle framel. A drain cock in the tank and 12 rinsers are provided to rinse the bottle. A stop cock to connect rubber tube is provided. Complete unit, supplied with 2 drill chucks to work on 220 Volts A/C. supply.
  • Tank size : 30" x 20" x 12" (chamber made of G.I. sheet)
  • Tank size : 30" x 20" x 18" (chamber made of G.I. sheet)
  • Tank size : 30" x 20" x 12" (chamber made of S.S)
  • Tank size : 30" x 20" x 18" (chamber made of S.S)
Fixed Speed Electrically operated with quick release chuck taking wide variety of interchangeable nylon brushes for cleaning syrings, test tubes and bottles. The electric motor and other systems are enclosed In metal case. Fixed speed.
Optional Fittings for EIE - 202 Electrically operated with quick release chuck taking wide variety of interchangeable nylon brushes for cleaning syrings, test tubes and bottles. The electric motor and other systems are enclosed In metal case. variable speed.
View Complete Details

Ultra Violet Lamp Assembly Box

Introduction: This is a portable dark room designed for viewing paper chromatographs and suitable for other gross studies of fluorescence effects.The cabinet is fitted with 125 watts lamp for long wave uses in radiation range 3200-400 AU. One ON/OFF switch on the top of the cabinet and the pilot lamp indicates the operation of the Lamp. Works on 220 V AC.
View Complete Details

Heating Mantle

Introduction With three heat control and energy regulator. Maximum Temp. : 450 C.
Capacity :50ml, 100ml, 250ml, 500ml, 1 Liter, 2 Liter, 3 Liter, 5 Liter, 10 Liter, 20 Liter, 50 Liter, 100 Liter, 200 Liter.
View Complete Details

High Speed Homogenizer

Introduction
  • High speed emulsifier with 1/8 HP 5000 RPM AC/DC motor control dimmerstat auto variac speed regulator. Cap.6-10 Ltrs.
  • High speed emulsifier with 1/4 HP 5000 RPM AC/DC motor and remote control dimmerstat auto variac speed regulator.Cap.15-20 ltrs.
  • High speed Emulsifier with 1/2 HP 6000 RPM AC\\DC motor and remote control dimmerstat auto variac speed regulator. Cap 25-35ltrs.
  • High speed Emulsifier with 3/4 HP 8000 RPM AC\\DC motor and remote control dimmerstat auto variac speed regulator. Cap 35-50ltrs.
  • High Speed emulsifier with 1 HP 10000 RPM AC\\DC motor and remote control dimmerstat auto variac a speed regulator. Cap. 40-60ltrs.
View Complete Details

Horizontal Autoclave

Contsrtuction The unit has outer chamber, inner chamber, Boiler, Lid and Jacket - all made of AISI 304 grade stainless steel. For controlling sterilization cycle, a three way valve or a multiport valve - made of S.S. is provided. The unit have a very efficient ms radial locking arrangement, fitted on ms ring, duly chrome plated. It is supplied complete with vaccum breaker, water level indicator, steam trap and automatic pressure control switch. The whole unit is mounted on a robust tubular ms stand. Operatable on single / three phase, 220/440 volts, 50Hz A.C. Supply.
Mode of Heating Electrically heated by special flange type / immersion type heaters bearing ISI mark, to work on single / three phase, 220/240 volts, 50Hz, A.C. supply.
Working Pressure The pressure inside the chamber is variable from 5 psi to 20 psi. But the normal recommended pressure for sterilization process is 1.2 Kgf/cm2 (15 psi).
Working Temperature : 121 deg.CWorking Pressure : 1.26 Kgf/cm2 (15 psi)Hydro Test Pressure : 2.5 Kgf/cm2 (35 psi)
Working Chamber
Size Volume Load (KW)
400 x 600 mm 78 Ltrs 6 KW
500 x 900 mm 135 Ltrs 10 KW
550 x 750 mm 152 Ltrs 9 KW
400 x 1100mm 162 Ltrs 12 KW
500 x 1200mm 185 Ltrs 12 KW
600 x 1200mm 300 Ltrs 18 KW
750 x 1200mm 525 Ltrs 18 KW
Optional Accessories
  • Semi Automatic Pressure Control Switch.
  • Automatic Low Water Cut Off Device
  • Mechanical Timer (0-60 Min)
  • Mechanical Timer With Alarm System
  • Solid State Digital Timer (0-120 Mins)
  • Solid State Digital Temperature Indicator.
  • Micro-Processor Based Programmable Timer Controller.
  • Micro-Processor Based Programmable Timer (0-120)
  • Circular Temperature Chart Recorder (24 Hours/Seven Days)
  • Strip Chart Recorder
  • Digital Pressure Transducer Cum Indicator
  • Automatic Pressure And Temperature Mapping System With Validation Soft Ware (Without Pc)
Rubber Gaskets Neoprene rubbler or silicon rubber
Size
250 X 450 MM
300 X 500 MM
350 X 550 MM
450 X 600 MM
500 x 1200mm
550 X 750 MM
Spare Heaters (In-house custom Developed SS Heaters)
2 KW
3 KW
4 KW
View Complete Details

KJELDAHL DIGESTION AND DISTILLATION APPARATUS

Introduction
  • EIE-5101 (G) For 3 Test Units
  • EIE-5101 (G) For 6 Test Units
EIE-5101 (G) For 3 Test Units With Individual Energy RegulatorOne single mild steel tubular stand provided with two heating shelves. One above the other in lower portion, a fume pipe and control box provided for digestion. Brass condenser rack with separate control box fitted in the upper portion provided for distillation. Supplied without glass parts and clamps. Mantle type/open heater type.
EIE-5101 (G) For 6 Test Units With Individual Energy RegulatorOne single mild steel tubular stand provided with two heating shelves. One above the other in lower portion, a fume pipe and control box provided for digestion. Brass condenser rack with separate control box fitted in the upper portion provided for distillation. Supplied without glass parts and clamps. Mantle type/open heater type.
View Complete Details

Kinematic Viscosity Bath

Introduction Used for determination of Kinematic and intrinsic viscosity of fuels, lubricants & petrochem raw materials at constant temperatures in accordance with ASTM D 445 and other equivalent methods. Available in two versions, to work at above ambient temperature and below ambient temperature.
General Descripation & Specifications Double walled, outer chamber made of G.I. - powder coated, with removable toughened Glass window panel, inner chamber made of S. S, FHP motorised stirrer for uniform temperature, Dual Display Microprocessor Based Digital Temp. Controller with PT-100 sensor. Temperature range from 5 C above ambient to 100 C., Control accuracy 0.1C. Below ambient Viscosity Baths are fitted with Refrigeration system (Temperature Range : 10C to 100C). The Baths can accommodate 2 / 4 / 8 Viscometers with varying tank volumes.
  • Stainless steel bath
  • Temperature controller (Thermostatic/Digital)
  • Immersion electric heater
  • Constant speed Pump cum stirrer
  • Carriage holding up to three standard briquette moulds
  • Electric motor with gear mechanism
  • Stainless steel scale and pointer
  • Control Panel
Reverse Flow Viscometer The viscometer is made of clear borosilicate glass free from visible defects. All glass tubing used in the construction of a single viscometer is of the same composition and the finished instrument is thoroughly annealed. The design and details of the viscometer are given at side. The size, approximate constant and Kinematic Viscosity is as per table.

Size No.

App. Const (cSt/s)

Kin. Viscosity

Range (cSt)

4

0.1

6 to 100

5

0.3

18 to 300

6

1.0

60 to 1000

7

3.0

180 to 3000

8

10

600 to 10000

9

30

1800 to 30000

10

100

6000 to 100000

11

300

18000 to 300000

viscosity range, is given in the table.
 

Size No.

App. Const (cSt/s)

Kin. Viscosity

Range (cSt)

150

0.035

2.1 to 35

200

0.1

6 to 100

300

0.25

15 to 200

350

0.5

30 to 500

400

1.2

72 to 1200

450

2.5

150 to 2500

500

8

480 to 8000

600

20

1200 to 20000

View Complete Details

Hot Air Drier

  • Chamber Size(cm) Tray  
  • Rating   H
  • W D
  •    
  • 90 90
  • 60 12
  • 4.5 KW 90
  • 18 6.0 KW
  • 120 90
  • 90 24
  • 7.0 KW 180
  • 90 60
  • 36 10.0 KW
  • 180 90
  • 90 48
Introduction: The large capacity Ovens and tray driers boasts generous size working chamber and the same time offers extremely uniform temperature distribution. These are quite suitable for industrial use like paint baking varnish baking, plastic granules drying, chemical & powder drying, electrode drying, teflon coating, annealing, core hardening, aging or preheating.
Construction: Heavy angle frame structure, covered with M.S sheet welded joints, glasswool insulation 100 mm thick. Tripple walled construction with mild-steel (or optionally stainless steel inner chamber) full size single or double door and runners for trolley at bottom level.(Trolley at extra cost)Air circulation from side or top motor & blower.
Heating & Controls: Heating is provided by long life tubular air heaters situated in the side cavities. The heaters are easily replaceable, Working temperature within oven is controlled by microprocessor based DUAL DISPLAY PID Digital temperature indicator cum controller. Main Switch, Heater selector switch, Amps meter, Volt meter, starter for motor, Contactor, indicating lamps are provided in control panel.
Size & Temprature: Tray driers of various standard sizes and as per the customers requirements are available. Bigger sizes and higher temperature on request. Working on 220 Volts AC single phase or 440V AC three phase as per the size of the drier.

The following are the standard sizes of drying Ovens available with working temp. from 50 deg C to 200 deg C. Prices are without tray

Optional Accessories (Extra):
  • M.S. Stand Trolley to accommodate 36 Trays.
  • M.S. Stand Trolley to accommodate 48 Trays.
  • Aluminium Tray : 18 SWG 16" 32" 1 1/4".
  • Aluminium Tray : 16 SWG 16" 32" 1 1/4"
  • Digital Timer for Time Setting
View Complete Details

Laboratory Stirrers

  •    
  •   EIE-1601-A Light Duty
  • Light Duty Stirrer, 1/20 HP 4000 RPM AC/DC Motor, S.S. shaft with chuck & mount on electronic speed regulator. Cap 6-8 ltrs.  
View Complete Details

Laminar Air Flow Unit

  • Direction of flow Horizontal
  • Cleanliness CLASS 100
  • Velocity 90 FPM +/- 20%
  • Hepa Filter Size and quantity will depend on the size selected
  • Particle retention Above 0.3 micron
  • Blower Assembly 1/3 HP, 1440 RPM
  • Noise level 65 decibel +/- 5%
  • Rate of air flow 0.40 to 0.75 M/Sec (90 FPM)
  • Vibration level 2.5 micron
EIE-2502 Vertical : Deluxe Model

Body made of cold rolled sheet duly powder coated. Table made of S. S. 304, front door of clear acrylic, UV lamps will be Phillips/equal imported make. Other standard accessories such as Manometer, gas inlet, castor wheels, illumination, additional power point are included in the price.

The Laminar Flow Cabinet can be made of S. S. Instead of mild steel at an extra cost . Price on request.

Pressure Differential Manometer will indicate the pressure behind the HEPA FILTER and after few years, the pressure will be more because of accumulation of dusts at the upstream side. Once the pressure level indicates above 22 mm WG in the manometer or the velocity at the downstream side falls below 60 feet per minute, the filters may be replaced. The velocity can be monitored by using external anemometer.

HEPA Filers Particleretention will be 0.3 micron at rated velocity, Pressure drop will be 23 mm WG, Efficiency 99.97%. Protected with specially perforated SS grill at the downstream side.
Pre-Filters size will depend on the size selected. Particle retention down to 15 micron at rated velocity, Pressure drop 6 mm WG, Efficiency 90 % Protected with specially perforated SS grill.
Blower Assembly consists of a 1/4 HP, 1440 RPM, single phase Motor with double end shaft and a pair of aluminum centrifugal type impeller directly coupled on both ends of the motor & encased within an MS blower housing.
Material of Construction The complete LAMINAR AIR FLOW BENCH will be fabricated by using Powder coated CRC sheet with square pipes. Front door made of 6 mm clear acrylic(polycarbonate at extra cost) with double folding facility. Working table will be of complete stainless steel. Ultra violet lamp of 3 feet 30 watts-Philips- Holland make will be provided.
Standard Accessories The equipment will be provided with 40 watt daylight lamps with diffusers, Gas cock, castor wheels, pressure differential manometer, additional 5 amps power point, side screens made of 6 mm clear acrylic.
View Complete Details

LIGHT WEIGHT MUFFLE FURNACE

Introduction

In this improved model, ceramic fiber wool insulation (instead of brick insulation) has been provided resulting in weight and size reduction of furnace. The weight and size of the furnace is 1/4 and 30% respectively as compared to brick furnace. The heat up time is less. heat loss is very low-resulting in power saving.

Construction CRC sheet with stoving enamel
Insulation Ceramic fiber wool insulation
Max. Temp. 1200°C
Working Temp 1150°C
Temp.control Dual display microprocessor based Digital temperature indicator cum controller with Cr/A1 Sensor
Heatings KANTHAL APM wire in coil form wound on the muffle, embedded in high grade refractory Cement.
Std.Fittings Compensating cable, indicating lamps, Power plug and cord.
Operation 220/230 Volts AC single phase.

Working size (L X W X D)
225 x 100 x 100 mm
250 x 125 x 125 mm
300 x 150 x 150 mm
300 x 200 x 200 mm
450 x 225 x 225 mm
 
NOTE : THE HEATING COILS OF THE FURNACE ARE WARRANTED FOR 1000 WORKING HOURS AT MAXIMUM WORKING TEMP. FROM THE DATE OF USAGE.
View Complete Details

Magnetic Stirrer

  • EIE-1603, Without Hot Plate
  • EIE-1603, With Hot Plate
Introduction Stainless steel body, S. S./epoxy coated top plate, variable speed control, with one Teflon coated magnetic stirring paddle.
Maximum capacity W X D X H paddleStirring speed Liters mm (dia X length) mm
1800 1 140x155x100 9 x 251800 2 160x165x120 9 x 351800 5 190x190x170 13 x 501200 10 250x250x170 13 x 50
View Complete Details

Shaking Machine For Flask

  • Platform Size To Hold
  • 12" x 12" 9 flasks of 250 ml
  • 18" x 18" 16 flasks of 100-250 ml.
  • 24" x 24" 36 flasks of 50 ml.
  • 24" x 24" 25 flasks of 250 ml.
  • 24" x 24" 16 flasks of 500 ml.
  • 24" x 24" 9 flasks of 1000 ml.
  • 36" x 36" 49 flasks of 100 ml.
  • 36" x 36" 36 flasks of 250 ml.
  • 36" x 36" 36 flasks of 500 ml.
  • 36" x 36" 16 flasks of 1000 ml.
  • 48" x 48" 100 flasks of 100 ml.
  • 48" x 48" 81 flasks of 250 ml.
  • 48" x 48" 64 flasks of 500 ml.
  • 48" x 48" 49 flasks of 1000ml.
  • 48" x 48" 16 flasks of 2000ml.
  • 60" x 60" Cap. Of flask as per requirement.
Introduction (With AC / DC Motor)

Useful for uniform mixing by circular motion in a horizontal plane with a circuit diameter of about 25 mm. Used extensively in tissue culture work, aeration of fermentation and other chemical mixing procedures. The driving mechanism is enclosed in a mild steel sheet cabinet beautifully painted. The motor used is induction type split phase and has a variable pitch pulley system with V belt drive, 150 to 250 oscillations approx. Optionally the shaker can be fitted with DC Motor with electronic speed regulator in place of variable pitch pulley system. The DC Motor will ensure continuous work and precise speed control. The shaking speed will be 50-250 RPM approx. The top platform have neoprene rubber discs to hold conical flask in between them.

Optional
  1. Automatic Electric Timer 0-60 minute for 24"x24", 36"x36" Shakers only.
  2. Digital RPM Counter for above models. Spare Platform For Above (Interchangeable)
  3. For 12" x 12" Shaker
  4. For 18" x 18" Shaker
  5. For 24" x 24" Shaker
For 36" x 36" ShakerFor 48" x 48" Shaker
Lotus type clamps flexible duly nickle with flexible spring instead of rubber disc. Per each clamp.Top platform stainless steel instead of mild steel platform.
Circular chart recorder - Daily / Weekly type.Fluorescent tube light provided with 24 hours ON/OFF Programmabletimer for Day /Night effect. Temp.range15 to 60C.at extra cost.Automatic Voltage Stabilizer.
View Complete Details

Refractometer

Introduction: An analytic apparatus that employs a manometer to determine changes in the amount of gas produced or absorbed by a test sample kept at constant temperature in a flask of constant gas volume and is used especially in the study of cellular respiration and metabolism and of some enzymatic reactions (as fermentation)
Polished Stainless Steel tank, with capacity of 7 manometers a side. Digital temperature display with resolution of 0.1 deg. C. Temperature control to within +/-0.5 deg. C. Stainless Steel immersion heater. Stirrer for uniform temperature. Manometers mounted on graduated scale for reading pressure changes. Flask with center well & side flask attached to manometer. Oscillation of manometer approximately 90 rpm. Powder coated exterior, with wheels for easy mobility. Capacity 7 manometers, temperature range of 5 deg. C above ambient to 60 deg. C.
View Complete Details

Rotary Vaccum Evaporator

Introduction: (New improved model with variable system and DC motor to work on 220 volt AC.) The apparatus consists of an evaporating flask rotated by non-sparking electric motor in heating water bath. The drive unit is clamped in V shaped heavy duty stand. The introduction tube permits continuous feed of the liquids into evaporating flask and also distillation under controlled atmosphere. The evaporating flask is pear shaped to give a large surface area for evaporation, clamped to a glass duct which goes through the drive unit and produced into the condenser is fitted with B-19 joint through which introduction tube is inserted. The condenser spherical join S-35 at the bottom of the condenser to receiver flasks cap, 1 litre of corning glass With ball point socket. Complete units is fitted on 'v' shape heavy duty stand with quick jack action. Waterbath and vacuum pump at extra cost.
View Complete Details

MULTIPLE SPINDLE STIRRER

Introduction: For uniform stirring up to six samples simultaneously. With variable speed 20 to 100 RPM approx. DC electric motor with electronic speed regulator. Strong M. S. Housing, stainless steel stirring paddles, arrangement to adjust paddle height, beakers up to 2000 ml. capacity can be used with ON/OFF switch and built in fluorescent tube. Supplied without glass beaker.
CAPACITY 1 Ltr. / 2 Ltrs:
  • For two stirrers.
  • For four stirrers.
  • For six stirrers.
  • Aluminium Tray : 16 SWG 16" 32" 1 1/4"
  • Digital Timer for Time Setting
OPTIONAL FITTING FOR ABOVE:
  • Timer 0-60 minutes, extra.
  • Speed revolution counter extra to cost. (Mechanical)
  • Microprocessor based Digital Speed Meter.
  • Attachment for feeding dose to all the stirring unit simultaneously.
  • For 2 stirrer jar test.
  • For 4 stirrer jar test.
  • For 6 stirrer jar test.
  • High speed jar test apparatus from 10 to 200 RPM.
  • Complete body stainless steel for 2 stirrer
  • Complete body stainless steel for 4 stirrer
  • Complete body stainless steel for 6 stirrer
View Complete Details

Sieve Shaker Table

Sieve Shaker - Table
Introduction (Soundless) Vibration type cast iron body. Electrically operated Fitted with FHPElectric Motor inside the Body having speed regulator to increase of discrease the vibration. The table sieve shaker having the capacity of 6 test sieves of 20cm.dai(without test sieve and time switch.) Adaptor for 30 cm dia test sieves .
Optional Extra:
  • Digital Time switch 0-99 minutes for above
  • Mechanical Time switch 0-60 minutes for above
View Complete Details

Tablet Coating Pan

Introduction: The machine fitted with gear box 1/2 H.P. electric Motorto work by Oil immersed gear box. Air blower is operated independently. An energy regulator is provided to control temperature from 5 deg.C above room temperature to 70 deg. C approx. Punch having switch for motor blower heat with neon indicator to work on 220 Volts. Size HP Pan HP Blower12" dia. 0.5 0.25
View Complete Details

ULTRA VIOLET LAMP ASSEMBLY-DUAL WAVE LENGTH

Introduction: Combined short wave, long wave and white light source.Cabinet for chromatographic analysis for ultra violet fluorescence analysis under laboratory conditions Chromatograms can be viewed with 3600-4000 A deg. long wave or 2500 A deg. short wave ultra violet or with white light. Can also be used in combination. Viewing the fluorescence is easy and comfortable with the hood at the top. Switches and starters are fitted atthe top for easy operation. With Or Without Filter
View Complete Details

Concrete Thermometer

Introduction Temperature of concrete at the time of placement is important to control and to avoid many possible difficulties. In hot climates, it is important to measure the temperature of the fresh concrete to ensure it is not too hot, which could cause flash setting and rapidly reducing workability. Measurements are generally taken at the point of placement.
General Description and specifications The Concrete Thermometers are available in following types.1. Mercury in Glass type or Alcohol in Glass type2. Dial type3. Digital type.
View Complete Details

Vee Bee Consistometer

Introduction The Veebe consistometer measures the remolding ability of concrete under vibration. The test results reflect the amount of energy required to remold a quantity of concrete under given vibration conditions. The Veebe consistometer is applicable to concrete with slumps less than 2 inches.
The apparatus, consists of a metal cylindrical container mounted on a vibrating table, which produces a sinusoidal vibration, a slump cone is placed in the center of the cylinder and filled in the same manner as in the standard slump test. After the slump cone is removed, a clear plastic disk is set atop the fresh concrete. The Veebe table is started and the time for the concrete to remold from the slump cone shape to the shape of the outer cylindrical container is recorded as a measure of consistency. The sliding clear plastic disk facilitates the determination of the end of the test.
General Description And Specification Consists of: A vibrating table, size 380mm long and 260mm wide, resting upon elastic support at a height of about 305mm above the floor, complete with start/stop switch cord and plug A holder is fixed to the base into which a swivel arm is telescoped with funnel and guide sleeve. The swivel arm is also detachable form vibrating Table. A graduated rod is fixed on a swivel arm and at its end a plastic disc is screwed. The divisions of scale on the rod record the slump of the concrete in millimeters. Supplied complete with a sheet metal. Container with lifting handles which can easily be fixed to the vibrating table. A slump cone open at both ends with lifting handles and a Tamping rod of size 16mm dia and 600mm long, rounded at one end. AS PER IS : 1199
Optional Accessories CONCRETE SCOOPSTOP WATCH
View Complete Details

Needle Vibrator

Introduction In the process of compaction, efforts are only directed to reduce voids in the compacted concrete. The Vibrators produce vibrations which when transmitted to plastic concrete make it to flow and affect compaction. The air bubbles are forced out of concrete due to vibrations.
The Needle Vibrator, also known as immersion or poker vibrator have a power unit and long flexible tube at the end of which a vibrating head is attached. Wherever compaction is to be done, the vibrating head is inserted in the concrete.
General Description And Specification The Laboratory needle vibrator having 350mm long X 25mm dia Needle is used in vibrating concrete test cylinders and beams in the field or laboratory. It is also widely used in making laboratory specimens, in making concrete products, in experimental works, and in small scale construction project. It has 1 meter long flexible shaft and is powered by 1 HP single Phase Electric motor.
The Needle vibrator for compaction of mass concrete has 40 or 60mm dia needle with 6 meter long flexible shaft and powered by 3 HP Electric motor for operation on 440 Volts, 3 phase, 50 cycles, A.C. Supply. Optionally, the Vibrator can also be fitted with Petrol/kerosene or Diesel Engine for field use.
Optional Accessories Spare Needle with shaft
View Complete Details

Hydraulic Jack

Introduction: Capacity : 10 Tonne, 20 Tonne, 25, Tonne, 50 Tonne, 100 Tonne, 150 Tonne and 200 Tonne.
Hand Operated: Hydraulic Jacks are of multipurpose utility i.e. application of loads while engaged in field investigation, determination of load carrying capacity of piles in the field, tensioning of wires in pre-cast structures, loading of members of any structures for deformation characteristics. For applying loads for various test in field or laboratory. Hydraulic Jack hand operated with separate pumping units. These jacks are portable available in various capacities. The pumping unit is connected to the hydraulic jack by means of a flexible connecting pipe 2 meter long. The jack is fitted with lifting handles for easy transportation. The approximate lift of the ram is 90 to 120 mm. The pumping unit is a single plunger type with detachable handle. The unit is fixed on a channeled base which is fitted with lifting handles. A pressure release valve is provided on the pumping unit. The load is indicated on a 15 cm dial hydraulic pressure gauge of appropriate capacity which can be detached from the pump when not in use. The least count of the calibrated dial will be according to the capacity of the gauge (Normally 100 divisions for full capacity). Lift of ram - 150 mm.
View Complete Details

Flow Table

Introduction The consistency and workability of concrete is a very important factor and is strictly connected to the water/cement ratio, to the effect of admixtures and finally to the strength and quality of concrete. Suitable for concrete mixes of high and very high workability. To perform this test, a sample is placed on a metal surface which is then raised and dropped through a known height.
General Description And Specification As per IS : 5512 for cement Mortar and LimeThe flow table consists of a brass table top 250 + 2.5mm dia mounted on a rigid stand. The table top is reinforced with equally disposed ribs and allowed to drop through 12mm by a ground and hardened cam, Complete with mould 100mm base dia, 70mm top dia and 50mm high. The cam shaft is rotated at the rate of 100 RPM by an electric motor. Suitable for operation on 230 Volts 50 cycles. Single Phase, A.C. Supply. Manually operated flow table also available.
Optional Accessories As per Is : 199 for concreteThe Flow Table consists of a brass or Mild steel table top of 76.2 cms(30")dia, finely machine from a solid brass casting or Mild steel Plate. The stand is fabricated out of cast iron/mild steel and is of study construction. The ground and hardened steel cam is designed to drop the table by 12.5mm. Complete with flow mould with handles with one tamping rod 0-60 cms long X 16cm. electrically operated to raise and drop the table top. approx. 15 times in 15 seconds. Suitable for operation on 230 volts, 50 cycles, A.C. Supply. Manually operated flow table also available.
Concrete scoop
View Complete Details

Concrete Mixer Laboratory

Introduction A concrete mixer is a device that homogeneously combines cement, aggregate such as sand or gravel, and water to form concrete. The mixer uses a revolving drum to mix the components. Uniform and thoroughly mixed batches can be produced in field or Laboratory. Inevitable for Mix design formulation.
General Descriptions & Specifications

The Concrete Mixers are available in two versions for Laboratory or field use. The field models are hand operated. This portable concrete mixer has rubber tyred wheelsand a towing tongue so that it can be towed and moved around by hand. Its rotationis powered by single-phase electric motor or by hand . The lever allows the concrete to be tipped into a wheel-barrowor mixing pan. The driving shaft is mounted on sealed ball bearing The counter balanced drum swivels and tilt 360 for easy and complete discharge.

Optional Accessories Wheel Barrow, Mixing Pan, concrete Scoop.
View Complete Details

Concrete Mixer Laboratory

Introduction A concrete mixer is a device that homogeneously combines cement, aggregate such as sand or gravel, and water to form concrete. The mixer uses a revolving drum to mix the components. Uniform and thoroughly mixed batches can be produced in field or Laboratory. Inevitable for Mix design formulation.
General Descriptions & Specifications The Concrete Mixers are available in two versions for Laboratory or field use. The field models are hand operated. This portable concrete mixer has rubber tyred wheelsand a towing tongue so that it can be towed and moved around by hand. Its rotationis powered by single-phase electric motor or by hand . The lever allows the concrete to be tipped into a wheel-barrowor mixing pan. The driving shaft is mounted on sealed ball bearing The counter balanced drum swivels and tilt 360 for easy and complete discharge.

Drum Capacity 3 cubic feet approximately
Drum material Cast Iron or mild steel
Mixer Capacity 2 cubic feet approximately
Drum Rotation 20-22
Motor Power 0.5 HP single Phase AC Supply / Hand operation
View Complete Details

Accelerated Curing Tank

Introduction The strength of concrete is generally estimated after 28 days by crushing field test cubes or cylinders made from the representative concrete used for the structure. The utility of ascertaining strength after 28 days is often questioned since by this time considerable concrete would have been placed and work may have progressed. It is then rather too late for remedial measures. It is therefore of tremendous advantage to predict 28 days strength within a few hours of casting the concrete so that, we have a good idea about the strength of the concrete.
The rate of gain of strength of concrete depends on the reaction rate of cement and additions with water (Hydration). In common with all chemical reactions, the rate of reaction depends on reaction of temp. Higher reaction temperature gives higher rate of reaction e.g. the concrete gains strength more rapidly when its temp. is higher. Accelerated curing is the process by which the temperature of the concrete is raised artificially by applying external heat to speed up the rate of gain in strength.
The test method covers procedures for curing test specimens of concrete stored under conditions intended to accelerate the development of strength. The procedures are: Procedure A- Warm Water Method, Procedure B-Boiling Water Method
General Description & Specification: Accelerated Curing Tank having capacity to accommodate 6/12/18 Concrete Cubes of 150mm size with a facility for accelerated curing by Boiling water method up to temperature range : 100 +/- 2 deg.C as per IS standard IS : 9013. Also it will have capacity for curing by warm water method at temperature 55 +/- 2 deg.C
Tank will consist of a rectangular double walled metal cabinet, inside lined with stainless steel, outer powder coated. Easily replaceable high Wattage heaters are mounted in side the chamber. A slow speed stirrer is provided to circulate water inside the chamber to maintain the uniform temperature of water. A strong stainless steel perforated platform is provided for keeping the cubes and also have a lid with lifting handle to cover the chamber.
The temperature is indicated and controlled by a DIGITAL auto tuning PID Temp. Controller with soak timer to control the duration of heating and then to shut down the system without manual attendance. The front panel will have power supply indicating lamp, control action indication lamp and one main switch. Suitable for operation on 220 V, 50 Hz single phase, AC supply or 440 V 50 Hz, three phase AC supply, for bigger size of curing tank.
Optional Accessories Rubber hand Gloves. Spare Heaters. Low water Level cut off device to safeguard heaters against low water level burn out In built refrigeration system for curing at 27 deg C
Recommended Accessories & Consumbles The following accessories and consumables are not part of the standard supply and are mandatory for the testing work
Also Available
Accelerated Curing Autoclave : By Steam Pressure
Accelerated Curing Drier : By Dry Heat
View Complete Details

Cube Mould

Introduction Cubes of fresh concrete are made to test a variety of properties on the eventually cured and hardened concrete. Fresh concrete is subjected to a standard compaction regime in the cube mould and is then normally initially cured under specific laboratory conditions. The moulds are manufactured, subject to tight dimensional, hardness, square ness and surface finish requirements.
General Description and specifications Complete with base plate. The faces of the mould are machined flat to +/- 0.02mm accuracy and finished to within +/- 0.2mm of specified dimensions. Material for construction of moulds is Cast Iron or Mild steel. The moulds are stout enough to prevent distortion and facilitate the removal of the moulded specimen without damage. The Moulds are so machined that when they are assembled ready for use, the dimensions and internal faces are accurate within the specified limits. Internal faces of the moulds are smooth.
The base plate is attached to the mould by cleats .The parts of the mould, when assembled, are positively and rigidly held together during filling, subsequent handling and vibration where applicable.
SIZES AVAILABLE : 50MM/ 100MM/ 150MM
Optional Accessory As per IS : 10086-1982, The cube mould is so constructed so as to facilitate separation into two parts. The mass of the mould together with the base plate will be 2.8 +/- 0.2 kg. Material for construction of these moulds is mild steel.
CUBE MOULD 7.06 CMS(FOR CEMENT MORTAR) SPANNER FOR DEMOULDING AND MOULDING, TAMPING ROD WITH SAUQRE FACE.
BEAM MOULDS For casting concrete specimens for flexural tests. The mould is made of 4 plates assembled together. Each mould with base plate, made of Mild Stee
View Complete Details

CYLINDRICAL MOLDS

ntroduction
  • 10cm x 20cm Made of Cast Iron with base plate
  • 15cm x 30cm Made of Cast Iron - with base plate
View Complete Details

Extensometer

Introduction The unit consists of two movable frames pivoted at one end. The lateral extensometer is fixed to the specimen with the help of tightening screws. The lateral extension is indicated on a dial gauge of 0.002 mm x 12 mm travel. The extension is magnified 2.5 times and the dial gauge readings are to be divided by 2.5 to get the exact readings. A spacer strip is provided to initially set the dial gauge and can be removed after initial setting. Supplied in a wooden carrying case.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Ctech Instruments from Ahmedabad, Gujarat.
Post Buy Requirement
CI
Ahmedabad, Gujarat, India
Add Review

Our Products

  1. Industrial Machinery 5 Products available
  2. Measuring Instruments & Equipment 4 Products available
  3. Laboratory Apparatus 8 Products available
  4. Lab Instrument 3 Products available
  5. Laboratory Equipments 5 Products available
  6. Laboratory Shakers 3 Products available
  7. Others 40 Products available

Other Products / Services #2605016

Riffle Sample Divider

Introduction

U.sed for rapid collection of the true representative sample from aggregate, sand and filters.

Consists of a metal box fitted with a series of chutes of equal width which discharge the material alternatively in opposite directions into separate pans. The chutes of the riffle are steep enough to allow rapid flowing of the material. Each riffle sample divider supplied with two pans and one scoop

Available in following sizes:

Size (mm)13202540No. of Slot14161616

View Complete Details

Buoyancy Balance

Consists of a rigid support frame, incorporating a water tank mounted on a platform. A mechanical lifting device is used to raise the water tank through the frame height immersing the specimen suspended below the balance. The balance supplied may also be used as a standard weighing device, thus providing a versatile and comprehensive weighing system in the laboratory
WEIGHING IN AIR AND IN WATER FRAME : Consisting of a rigid frame, water tank, and cradle.

View Complete Details

Elongation Gauge

Introduction Used to determine the Elongation Index of the Aggregate. Aggregate particles are considered elongated when their length is more than 1.8 of the nominal size. It consists of a hard wood base with vertically mounted metal studs as specified in the IS.
View Complete Details

Jaw Crusher Laboratory

Introduction Laboratory Jaw Crusher is designed to speed up the crushing of aggregate, ores, minerals, coal, coke, chemicals and other similar materials. Its compact and of rugged construction is advantageous for general laboratory or small pilot plant operations.
wo jaws of manganese steel are provided in the jaw crusher. The moveable jaw produces two blows for every revolution, thus reducing over sizing to a minimum. A combination of forward and downward and strokes with a rocking action exerts pressure on the coarse material to pass through the jaws. A hopper is provided at the top for feeding materials. The smooth jaws ensure a uniform product and easy cleaning is possible.
Max Size of feed 50mm (approximately) Product discharge
Size of feed 6mm to 18mm (adjustable)
Capacity 80kG/hr (approximately - based on material)
Operation On 440 volt, 3 Phase, 50hz, A.C. supply with 3H.P.
Electric motor motor, a starter ' v ' belt pulley drive and mounting
View Complete Details

Density Basket

Introduction Used for specific gravity and water absorption test of aggregate. The basket is used in conjunction with a suitable electronic balance, a specially designed robust frame to support the electronic balance and water tight container.
The Density basket is of 20cm dia x 20cm high fitted with galvanized wire mesh of 6.3mm with handle for suspending it from the balance.
Optional Accessories: The following accessories are not part of the standard supply and are supplied at an extra cost.
  • Electronic Balance capacity 5 kg x 0.5gm / 5 kg x 0.1 gm with under bench weighing facility.
  • Laboratory Oven.
  • Water tight container.
A specially designed frame with moving platform to carry the water container allowing the test specimens to be weighed in both air and water.
View Complete Details

Flakiness Gauge

Introduction Used to determine the flakiness index of the aggregate. The aggregate particles are to be considered flaky, if their thickness is less than 0.6 of their nominal size.
It consists of a frame with sliding panel with accurate slots of different standard width and length, the complete assembly is chrome plated or powder coated.
View Complete Details

Vertical Autoclave

Introduction: Our vertical autoclaves are widely used for the day to day sterilization procedures and in various laboratory applications.We specialize in both standard and customized models, specifically designed to meet the challenging demands of various scientists for individual and specialized research applications. Apart from that, we are also supplying our economical autoclave in India catering to variety of customers ranging from Defense Installations, Research Laboratories and Educational Institutes and various R&D laboratories of leading national and multinational companies.
View Complete Details

Bottle Washing Machine

Introduction
  • EIE-1805 With Soaking Tank
  • EIE-1805 Fixed Speed
  • EIE-1805 Variable Speed
With Soaking Tank Electrically operated, fitted with H.P. Motor, coupled by means of pulley of two chucks into which different sizes of bushed can be fixed. The speed of motor is approx.450 RPM. An aluminium anodized baffle is placed so that water may not splash. The motor unit is covered by metal guard. The soaking unit is mounted on angle framel. A drain cock in the tank and 12 rinsers are provided to rinse the bottle. A stop cock to connect rubber tube is provided. Complete unit, supplied with 2 drill chucks to work on 220 Volts A/C. supply.
  • Tank size : 30" x 20" x 12" (chamber made of G.I. sheet)
  • Tank size : 30" x 20" x 18" (chamber made of G.I. sheet)
  • Tank size : 30" x 20" x 12" (chamber made of S.S)
  • Tank size : 30" x 20" x 18" (chamber made of S.S)
Fixed Speed Electrically operated with quick release chuck taking wide variety of interchangeable nylon brushes for cleaning syrings, test tubes and bottles. The electric motor and other systems are enclosed In metal case. Fixed speed.
Optional Fittings for EIE - 202 Electrically operated with quick release chuck taking wide variety of interchangeable nylon brushes for cleaning syrings, test tubes and bottles. The electric motor and other systems are enclosed In metal case. variable speed.
View Complete Details

Ultra Violet Lamp Assembly Box

Introduction: This is a portable dark room designed for viewing paper chromatographs and suitable for other gross studies of fluorescence effects.The cabinet is fitted with 125 watts lamp for long wave uses in radiation range 3200-400 AU. One ON/OFF switch on the top of the cabinet and the pilot lamp indicates the operation of the Lamp. Works on 220 V AC.
View Complete Details

Heating Mantle

Introduction With three heat control and energy regulator. Maximum Temp. : 450 C.
Capacity :50ml, 100ml, 250ml, 500ml, 1 Liter, 2 Liter, 3 Liter, 5 Liter, 10 Liter, 20 Liter, 50 Liter, 100 Liter, 200 Liter.
View Complete Details

High Speed Homogenizer

Introduction
  • High speed emulsifier with 1/8 HP 5000 RPM AC/DC motor control dimmerstat auto variac speed regulator. Cap.6-10 Ltrs.
  • High speed emulsifier with 1/4 HP 5000 RPM AC/DC motor and remote control dimmerstat auto variac speed regulator.Cap.15-20 ltrs.
  • High speed Emulsifier with 1/2 HP 6000 RPM AC\\DC motor and remote control dimmerstat auto variac speed regulator. Cap 25-35ltrs.
  • High speed Emulsifier with 3/4 HP 8000 RPM AC\\DC motor and remote control dimmerstat auto variac speed regulator. Cap 35-50ltrs.
  • High Speed emulsifier with 1 HP 10000 RPM AC\\DC motor and remote control dimmerstat auto variac a speed regulator. Cap. 40-60ltrs.
View Complete Details

Horizontal Autoclave

Contsrtuction The unit has outer chamber, inner chamber, Boiler, Lid and Jacket - all made of AISI 304 grade stainless steel. For controlling sterilization cycle, a three way valve or a multiport valve - made of S.S. is provided. The unit have a very efficient ms radial locking arrangement, fitted on ms ring, duly chrome plated. It is supplied complete with vaccum breaker, water level indicator, steam trap and automatic pressure control switch. The whole unit is mounted on a robust tubular ms stand. Operatable on single / three phase, 220/440 volts, 50Hz A.C. Supply.
Mode of Heating Electrically heated by special flange type / immersion type heaters bearing ISI mark, to work on single / three phase, 220/240 volts, 50Hz, A.C. supply.
Working Pressure The pressure inside the chamber is variable from 5 psi to 20 psi. But the normal recommended pressure for sterilization process is 1.2 Kgf/cm2 (15 psi).
Working Temperature : 121 deg.CWorking Pressure : 1.26 Kgf/cm2 (15 psi)Hydro Test Pressure : 2.5 Kgf/cm2 (35 psi)
Working Chamber
Size Volume Load (KW)
400 x 600 mm 78 Ltrs 6 KW
500 x 900 mm 135 Ltrs 10 KW
550 x 750 mm 152 Ltrs 9 KW
400 x 1100mm 162 Ltrs 12 KW
500 x 1200mm 185 Ltrs 12 KW
600 x 1200mm 300 Ltrs 18 KW
750 x 1200mm 525 Ltrs 18 KW
Optional Accessories
  • Semi Automatic Pressure Control Switch.
  • Automatic Low Water Cut Off Device
  • Mechanical Timer (0-60 Min)
  • Mechanical Timer With Alarm System
  • Solid State Digital Timer (0-120 Mins)
  • Solid State Digital Temperature Indicator.
  • Micro-Processor Based Programmable Timer Controller.
  • Micro-Processor Based Programmable Timer (0-120)
  • Circular Temperature Chart Recorder (24 Hours/Seven Days)
  • Strip Chart Recorder
  • Digital Pressure Transducer Cum Indicator
  • Automatic Pressure And Temperature Mapping System With Validation Soft Ware (Without Pc)
Rubber Gaskets Neoprene rubbler or silicon rubber
Size
250 X 450 MM
300 X 500 MM
350 X 550 MM
450 X 600 MM
500 x 1200mm
550 X 750 MM
Spare Heaters (In-house custom Developed SS Heaters)
2 KW
3 KW
4 KW
View Complete Details

KJELDAHL DIGESTION AND DISTILLATION APPARATUS

Introduction
  • EIE-5101 (G) For 3 Test Units
  • EIE-5101 (G) For 6 Test Units
EIE-5101 (G) For 3 Test Units With Individual Energy RegulatorOne single mild steel tubular stand provided with two heating shelves. One above the other in lower portion, a fume pipe and control box provided for digestion. Brass condenser rack with separate control box fitted in the upper portion provided for distillation. Supplied without glass parts and clamps. Mantle type/open heater type.
EIE-5101 (G) For 6 Test Units With Individual Energy RegulatorOne single mild steel tubular stand provided with two heating shelves. One above the other in lower portion, a fume pipe and control box provided for digestion. Brass condenser rack with separate control box fitted in the upper portion provided for distillation. Supplied without glass parts and clamps. Mantle type/open heater type.
View Complete Details

Kinematic Viscosity Bath

Introduction Used for determination of Kinematic and intrinsic viscosity of fuels, lubricants & petrochem raw materials at constant temperatures in accordance with ASTM D 445 and other equivalent methods. Available in two versions, to work at above ambient temperature and below ambient temperature.
General Descripation & Specifications Double walled, outer chamber made of G.I. - powder coated, with removable toughened Glass window panel, inner chamber made of S. S, FHP motorised stirrer for uniform temperature, Dual Display Microprocessor Based Digital Temp. Controller with PT-100 sensor. Temperature range from 5 C above ambient to 100 C., Control accuracy 0.1C. Below ambient Viscosity Baths are fitted with Refrigeration system (Temperature Range : 10C to 100C). The Baths can accommodate 2 / 4 / 8 Viscometers with varying tank volumes.
  • Stainless steel bath
  • Temperature controller (Thermostatic/Digital)
  • Immersion electric heater
  • Constant speed Pump cum stirrer
  • Carriage holding up to three standard briquette moulds
  • Electric motor with gear mechanism
  • Stainless steel scale and pointer
  • Control Panel
Reverse Flow Viscometer The viscometer is made of clear borosilicate glass free from visible defects. All glass tubing used in the construction of a single viscometer is of the same composition and the finished instrument is thoroughly annealed. The design and details of the viscometer are given at side. The size, approximate constant and Kinematic Viscosity is as per table.

Size No.

App. Const (cSt/s)

Kin. Viscosity

Range (cSt)

4

0.1

6 to 100

5

0.3

18 to 300

6

1.0

60 to 1000

7

3.0

180 to 3000

8

10

600 to 10000

9

30

1800 to 30000

10

100

6000 to 100000

11

300

18000 to 300000

viscosity range, is given in the table.
 

Size No.

App. Const (cSt/s)

Kin. Viscosity

Range (cSt)

150

0.035

2.1 to 35

200

0.1

6 to 100

300

0.25

15 to 200

350

0.5

30 to 500

400

1.2

72 to 1200

450

2.5

150 to 2500

500

8

480 to 8000

600

20

1200 to 20000

View Complete Details

Hot Air Drier

  • Chamber Size(cm) Tray  
  • Rating   H
  • W D
  •    
  • 90 90
  • 60 12
  • 4.5 KW 90
  • 18 6.0 KW
  • 120 90
  • 90 24
  • 7.0 KW 180
  • 90 60
  • 36 10.0 KW
  • 180 90
  • 90 48
Introduction: The large capacity Ovens and tray driers boasts generous size working chamber and the same time offers extremely uniform temperature distribution. These are quite suitable for industrial use like paint baking varnish baking, plastic granules drying, chemical & powder drying, electrode drying, teflon coating, annealing, core hardening, aging or preheating.
Construction: Heavy angle frame structure, covered with M.S sheet welded joints, glasswool insulation 100 mm thick. Tripple walled construction with mild-steel (or optionally stainless steel inner chamber) full size single or double door and runners for trolley at bottom level.(Trolley at extra cost)Air circulation from side or top motor & blower.
Heating & Controls: Heating is provided by long life tubular air heaters situated in the side cavities. The heaters are easily replaceable, Working temperature within oven is controlled by microprocessor based DUAL DISPLAY PID Digital temperature indicator cum controller. Main Switch, Heater selector switch, Amps meter, Volt meter, starter for motor, Contactor, indicating lamps are provided in control panel.
Size & Temprature: Tray driers of various standard sizes and as per the customers requirements are available. Bigger sizes and higher temperature on request. Working on 220 Volts AC single phase or 440V AC three phase as per the size of the drier.

The following are the standard sizes of drying Ovens available with working temp. from 50 deg C to 200 deg C. Prices are without tray

Optional Accessories (Extra):
  • M.S. Stand Trolley to accommodate 36 Trays.
  • M.S. Stand Trolley to accommodate 48 Trays.
  • Aluminium Tray : 18 SWG 16" 32" 1 1/4".
  • Aluminium Tray : 16 SWG 16" 32" 1 1/4"
  • Digital Timer for Time Setting
View Complete Details

Laboratory Stirrers

  •    
  •   EIE-1601-A Light Duty
  • Light Duty Stirrer, 1/20 HP 4000 RPM AC/DC Motor, S.S. shaft with chuck & mount on electronic speed regulator. Cap 6-8 ltrs.  
View Complete Details

Laminar Air Flow Unit

  • Direction of flow Horizontal
  • Cleanliness CLASS 100
  • Velocity 90 FPM +/- 20%
  • Hepa Filter Size and quantity will depend on the size selected
  • Particle retention Above 0.3 micron
  • Blower Assembly 1/3 HP, 1440 RPM
  • Noise level 65 decibel +/- 5%
  • Rate of air flow 0.40 to 0.75 M/Sec (90 FPM)
  • Vibration level 2.5 micron
EIE-2502 Vertical : Deluxe Model

Body made of cold rolled sheet duly powder coated. Table made of S. S. 304, front door of clear acrylic, UV lamps will be Phillips/equal imported make. Other standard accessories such as Manometer, gas inlet, castor wheels, illumination, additional power point are included in the price.

The Laminar Flow Cabinet can be made of S. S. Instead of mild steel at an extra cost . Price on request.

Pressure Differential Manometer will indicate the pressure behind the HEPA FILTER and after few years, the pressure will be more because of accumulation of dusts at the upstream side. Once the pressure level indicates above 22 mm WG in the manometer or the velocity at the downstream side falls below 60 feet per minute, the filters may be replaced. The velocity can be monitored by using external anemometer.

HEPA Filers Particleretention will be 0.3 micron at rated velocity, Pressure drop will be 23 mm WG, Efficiency 99.97%. Protected with specially perforated SS grill at the downstream side.
Pre-Filters size will depend on the size selected. Particle retention down to 15 micron at rated velocity, Pressure drop 6 mm WG, Efficiency 90 % Protected with specially perforated SS grill.
Blower Assembly consists of a 1/4 HP, 1440 RPM, single phase Motor with double end shaft and a pair of aluminum centrifugal type impeller directly coupled on both ends of the motor & encased within an MS blower housing.
Material of Construction The complete LAMINAR AIR FLOW BENCH will be fabricated by using Powder coated CRC sheet with square pipes. Front door made of 6 mm clear acrylic(polycarbonate at extra cost) with double folding facility. Working table will be of complete stainless steel. Ultra violet lamp of 3 feet 30 watts-Philips- Holland make will be provided.
Standard Accessories The equipment will be provided with 40 watt daylight lamps with diffusers, Gas cock, castor wheels, pressure differential manometer, additional 5 amps power point, side screens made of 6 mm clear acrylic.
View Complete Details

LIGHT WEIGHT MUFFLE FURNACE

Introduction

In this improved model, ceramic fiber wool insulation (instead of brick insulation) has been provided resulting in weight and size reduction of furnace. The weight and size of the furnace is 1/4 and 30% respectively as compared to brick furnace. The heat up time is less. heat loss is very low-resulting in power saving.

Construction CRC sheet with stoving enamel
Insulation Ceramic fiber wool insulation
Max. Temp. 1200°C
Working Temp 1150°C
Temp.control Dual display microprocessor based Digital temperature indicator cum controller with Cr/A1 Sensor
Heatings KANTHAL APM wire in coil form wound on the muffle, embedded in high grade refractory Cement.
Std.Fittings Compensating cable, indicating lamps, Power plug and cord.
Operation 220/230 Volts AC single phase.

Working size (L X W X D)
225 x 100 x 100 mm
250 x 125 x 125 mm
300 x 150 x 150 mm
300 x 200 x 200 mm
450 x 225 x 225 mm
 
NOTE : THE HEATING COILS OF THE FURNACE ARE WARRANTED FOR 1000 WORKING HOURS AT MAXIMUM WORKING TEMP. FROM THE DATE OF USAGE.
View Complete Details

Magnetic Stirrer

  • EIE-1603, Without Hot Plate
  • EIE-1603, With Hot Plate
Introduction Stainless steel body, S. S./epoxy coated top plate, variable speed control, with one Teflon coated magnetic stirring paddle.
Maximum capacity W X D X H paddleStirring speed Liters mm (dia X length) mm
1800 1 140x155x100 9 x 251800 2 160x165x120 9 x 351800 5 190x190x170 13 x 501200 10 250x250x170 13 x 50
View Complete Details

Shaking Machine For Flask

  • Platform Size To Hold
  • 12" x 12" 9 flasks of 250 ml
  • 18" x 18" 16 flasks of 100-250 ml.
  • 24" x 24" 36 flasks of 50 ml.
  • 24" x 24" 25 flasks of 250 ml.
  • 24" x 24" 16 flasks of 500 ml.
  • 24" x 24" 9 flasks of 1000 ml.
  • 36" x 36" 49 flasks of 100 ml.
  • 36" x 36" 36 flasks of 250 ml.
  • 36" x 36" 36 flasks of 500 ml.
  • 36" x 36" 16 flasks of 1000 ml.
  • 48" x 48" 100 flasks of 100 ml.
  • 48" x 48" 81 flasks of 250 ml.
  • 48" x 48" 64 flasks of 500 ml.
  • 48" x 48" 49 flasks of 1000ml.
  • 48" x 48" 16 flasks of 2000ml.
  • 60" x 60" Cap. Of flask as per requirement.
Introduction (With AC / DC Motor)

Useful for uniform mixing by circular motion in a horizontal plane with a circuit diameter of about 25 mm. Used extensively in tissue culture work, aeration of fermentation and other chemical mixing procedures. The driving mechanism is enclosed in a mild steel sheet cabinet beautifully painted. The motor used is induction type split phase and has a variable pitch pulley system with V belt drive, 150 to 250 oscillations approx. Optionally the shaker can be fitted with DC Motor with electronic speed regulator in place of variable pitch pulley system. The DC Motor will ensure continuous work and precise speed control. The shaking speed will be 50-250 RPM approx. The top platform have neoprene rubber discs to hold conical flask in between them.

Optional
  1. Automatic Electric Timer 0-60 minute for 24"x24", 36"x36" Shakers only.
  2. Digital RPM Counter for above models. Spare Platform For Above (Interchangeable)
  3. For 12" x 12" Shaker
  4. For 18" x 18" Shaker
  5. For 24" x 24" Shaker
For 36" x 36" ShakerFor 48" x 48" Shaker
Lotus type clamps flexible duly nickle with flexible spring instead of rubber disc. Per each clamp.Top platform stainless steel instead of mild steel platform.
Circular chart recorder - Daily / Weekly type.Fluorescent tube light provided with 24 hours ON/OFF Programmabletimer for Day /Night effect. Temp.range15 to 60C.at extra cost.Automatic Voltage Stabilizer.
View Complete Details

Refractometer

Introduction: An analytic apparatus that employs a manometer to determine changes in the amount of gas produced or absorbed by a test sample kept at constant temperature in a flask of constant gas volume and is used especially in the study of cellular respiration and metabolism and of some enzymatic reactions (as fermentation)
Polished Stainless Steel tank, with capacity of 7 manometers a side. Digital temperature display with resolution of 0.1 deg. C. Temperature control to within +/-0.5 deg. C. Stainless Steel immersion heater. Stirrer for uniform temperature. Manometers mounted on graduated scale for reading pressure changes. Flask with center well & side flask attached to manometer. Oscillation of manometer approximately 90 rpm. Powder coated exterior, with wheels for easy mobility. Capacity 7 manometers, temperature range of 5 deg. C above ambient to 60 deg. C.
View Complete Details

Rotary Vaccum Evaporator

Introduction: (New improved model with variable system and DC motor to work on 220 volt AC.) The apparatus consists of an evaporating flask rotated by non-sparking electric motor in heating water bath. The drive unit is clamped in V shaped heavy duty stand. The introduction tube permits continuous feed of the liquids into evaporating flask and also distillation under controlled atmosphere. The evaporating flask is pear shaped to give a large surface area for evaporation, clamped to a glass duct which goes through the drive unit and produced into the condenser is fitted with B-19 joint through which introduction tube is inserted. The condenser spherical join S-35 at the bottom of the condenser to receiver flasks cap, 1 litre of corning glass With ball point socket. Complete units is fitted on 'v' shape heavy duty stand with quick jack action. Waterbath and vacuum pump at extra cost.
View Complete Details

MULTIPLE SPINDLE STIRRER

Introduction: For uniform stirring up to six samples simultaneously. With variable speed 20 to 100 RPM approx. DC electric motor with electronic speed regulator. Strong M. S. Housing, stainless steel stirring paddles, arrangement to adjust paddle height, beakers up to 2000 ml. capacity can be used with ON/OFF switch and built in fluorescent tube. Supplied without glass beaker.
CAPACITY 1 Ltr. / 2 Ltrs:
  • For two stirrers.
  • For four stirrers.
  • For six stirrers.
  • Aluminium Tray : 16 SWG 16" 32" 1 1/4"
  • Digital Timer for Time Setting
OPTIONAL FITTING FOR ABOVE:
  • Timer 0-60 minutes, extra.
  • Speed revolution counter extra to cost. (Mechanical)
  • Microprocessor based Digital Speed Meter.
  • Attachment for feeding dose to all the stirring unit simultaneously.
  • For 2 stirrer jar test.
  • For 4 stirrer jar test.
  • For 6 stirrer jar test.
  • High speed jar test apparatus from 10 to 200 RPM.
  • Complete body stainless steel for 2 stirrer
  • Complete body stainless steel for 4 stirrer
  • Complete body stainless steel for 6 stirrer
View Complete Details

Sieve Shaker Table

Sieve Shaker - Table
Introduction (Soundless) Vibration type cast iron body. Electrically operated Fitted with FHPElectric Motor inside the Body having speed regulator to increase of discrease the vibration. The table sieve shaker having the capacity of 6 test sieves of 20cm.dai(without test sieve and time switch.) Adaptor for 30 cm dia test sieves .
Optional Extra:
  • Digital Time switch 0-99 minutes for above
  • Mechanical Time switch 0-60 minutes for above
View Complete Details

Tablet Coating Pan

Introduction: The machine fitted with gear box 1/2 H.P. electric Motorto work by Oil immersed gear box. Air blower is operated independently. An energy regulator is provided to control temperature from 5 deg.C above room temperature to 70 deg. C approx. Punch having switch for motor blower heat with neon indicator to work on 220 Volts. Size HP Pan HP Blower12" dia. 0.5 0.25
View Complete Details

ULTRA VIOLET LAMP ASSEMBLY-DUAL WAVE LENGTH

Introduction: Combined short wave, long wave and white light source.Cabinet for chromatographic analysis for ultra violet fluorescence analysis under laboratory conditions Chromatograms can be viewed with 3600-4000 A deg. long wave or 2500 A deg. short wave ultra violet or with white light. Can also be used in combination. Viewing the fluorescence is easy and comfortable with the hood at the top. Switches and starters are fitted atthe top for easy operation. With Or Without Filter
View Complete Details

Concrete Thermometer

Introduction Temperature of concrete at the time of placement is important to control and to avoid many possible difficulties. In hot climates, it is important to measure the temperature of the fresh concrete to ensure it is not too hot, which could cause flash setting and rapidly reducing workability. Measurements are generally taken at the point of placement.
General Description and specifications The Concrete Thermometers are available in following types.1. Mercury in Glass type or Alcohol in Glass type2. Dial type3. Digital type.
View Complete Details

Vee Bee Consistometer

Introduction The Veebe consistometer measures the remolding ability of concrete under vibration. The test results reflect the amount of energy required to remold a quantity of concrete under given vibration conditions. The Veebe consistometer is applicable to concrete with slumps less than 2 inches.
The apparatus, consists of a metal cylindrical container mounted on a vibrating table, which produces a sinusoidal vibration, a slump cone is placed in the center of the cylinder and filled in the same manner as in the standard slump test. After the slump cone is removed, a clear plastic disk is set atop the fresh concrete. The Veebe table is started and the time for the concrete to remold from the slump cone shape to the shape of the outer cylindrical container is recorded as a measure of consistency. The sliding clear plastic disk facilitates the determination of the end of the test.
General Description And Specification Consists of: A vibrating table, size 380mm long and 260mm wide, resting upon elastic support at a height of about 305mm above the floor, complete with start/stop switch cord and plug A holder is fixed to the base into which a swivel arm is telescoped with funnel and guide sleeve. The swivel arm is also detachable form vibrating Table. A graduated rod is fixed on a swivel arm and at its end a plastic disc is screwed. The divisions of scale on the rod record the slump of the concrete in millimeters. Supplied complete with a sheet metal. Container with lifting handles which can easily be fixed to the vibrating table. A slump cone open at both ends with lifting handles and a Tamping rod of size 16mm dia and 600mm long, rounded at one end. AS PER IS : 1199
Optional Accessories CONCRETE SCOOPSTOP WATCH
View Complete Details

Needle Vibrator

Introduction In the process of compaction, efforts are only directed to reduce voids in the compacted concrete. The Vibrators produce vibrations which when transmitted to plastic concrete make it to flow and affect compaction. The air bubbles are forced out of concrete due to vibrations.
The Needle Vibrator, also known as immersion or poker vibrator have a power unit and long flexible tube at the end of which a vibrating head is attached. Wherever compaction is to be done, the vibrating head is inserted in the concrete.
General Description And Specification The Laboratory needle vibrator having 350mm long X 25mm dia Needle is used in vibrating concrete test cylinders and beams in the field or laboratory. It is also widely used in making laboratory specimens, in making concrete products, in experimental works, and in small scale construction project. It has 1 meter long flexible shaft and is powered by 1 HP single Phase Electric motor.
The Needle vibrator for compaction of mass concrete has 40 or 60mm dia needle with 6 meter long flexible shaft and powered by 3 HP Electric motor for operation on 440 Volts, 3 phase, 50 cycles, A.C. Supply. Optionally, the Vibrator can also be fitted with Petrol/kerosene or Diesel Engine for field use.
Optional Accessories Spare Needle with shaft
View Complete Details

Hydraulic Jack

Introduction: Capacity : 10 Tonne, 20 Tonne, 25, Tonne, 50 Tonne, 100 Tonne, 150 Tonne and 200 Tonne.
Hand Operated: Hydraulic Jacks are of multipurpose utility i.e. application of loads while engaged in field investigation, determination of load carrying capacity of piles in the field, tensioning of wires in pre-cast structures, loading of members of any structures for deformation characteristics. For applying loads for various test in field or laboratory. Hydraulic Jack hand operated with separate pumping units. These jacks are portable available in various capacities. The pumping unit is connected to the hydraulic jack by means of a flexible connecting pipe 2 meter long. The jack is fitted with lifting handles for easy transportation. The approximate lift of the ram is 90 to 120 mm. The pumping unit is a single plunger type with detachable handle. The unit is fixed on a channeled base which is fitted with lifting handles. A pressure release valve is provided on the pumping unit. The load is indicated on a 15 cm dial hydraulic pressure gauge of appropriate capacity which can be detached from the pump when not in use. The least count of the calibrated dial will be according to the capacity of the gauge (Normally 100 divisions for full capacity). Lift of ram - 150 mm.
View Complete Details

Flow Table

Introduction The consistency and workability of concrete is a very important factor and is strictly connected to the water/cement ratio, to the effect of admixtures and finally to the strength and quality of concrete. Suitable for concrete mixes of high and very high workability. To perform this test, a sample is placed on a metal surface which is then raised and dropped through a known height.
General Description And Specification As per IS : 5512 for cement Mortar and LimeThe flow table consists of a brass table top 250 + 2.5mm dia mounted on a rigid stand. The table top is reinforced with equally disposed ribs and allowed to drop through 12mm by a ground and hardened cam, Complete with mould 100mm base dia, 70mm top dia and 50mm high. The cam shaft is rotated at the rate of 100 RPM by an electric motor. Suitable for operation on 230 Volts 50 cycles. Single Phase, A.C. Supply. Manually operated flow table also available.
Optional Accessories As per Is : 199 for concreteThe Flow Table consists of a brass or Mild steel table top of 76.2 cms(30")dia, finely machine from a solid brass casting or Mild steel Plate. The stand is fabricated out of cast iron/mild steel and is of study construction. The ground and hardened steel cam is designed to drop the table by 12.5mm. Complete with flow mould with handles with one tamping rod 0-60 cms long X 16cm. electrically operated to raise and drop the table top. approx. 15 times in 15 seconds. Suitable for operation on 230 volts, 50 cycles, A.C. Supply. Manually operated flow table also available.
Concrete scoop
View Complete Details

Concrete Mixer Laboratory

Introduction A concrete mixer is a device that homogeneously combines cement, aggregate such as sand or gravel, and water to form concrete. The mixer uses a revolving drum to mix the components. Uniform and thoroughly mixed batches can be produced in field or Laboratory. Inevitable for Mix design formulation.
General Descriptions & Specifications

The Concrete Mixers are available in two versions for Laboratory or field use. The field models are hand operated. This portable concrete mixer has rubber tyred wheelsand a towing tongue so that it can be towed and moved around by hand. Its rotationis powered by single-phase electric motor or by hand . The lever allows the concrete to be tipped into a wheel-barrowor mixing pan. The driving shaft is mounted on sealed ball bearing The counter balanced drum swivels and tilt 360 for easy and complete discharge.

Optional Accessories Wheel Barrow, Mixing Pan, concrete Scoop.
View Complete Details

Concrete Mixer Laboratory

Introduction A concrete mixer is a device that homogeneously combines cement, aggregate such as sand or gravel, and water to form concrete. The mixer uses a revolving drum to mix the components. Uniform and thoroughly mixed batches can be produced in field or Laboratory. Inevitable for Mix design formulation.
General Descriptions & Specifications The Concrete Mixers are available in two versions for Laboratory or field use. The field models are hand operated. This portable concrete mixer has rubber tyred wheelsand a towing tongue so that it can be towed and moved around by hand. Its rotationis powered by single-phase electric motor or by hand . The lever allows the concrete to be tipped into a wheel-barrowor mixing pan. The driving shaft is mounted on sealed ball bearing The counter balanced drum swivels and tilt 360 for easy and complete discharge.

Drum Capacity 3 cubic feet approximately
Drum material Cast Iron or mild steel
Mixer Capacity 2 cubic feet approximately
Drum Rotation 20-22
Motor Power 0.5 HP single Phase AC Supply / Hand operation
View Complete Details

Accelerated Curing Tank

Introduction The strength of concrete is generally estimated after 28 days by crushing field test cubes or cylinders made from the representative concrete used for the structure. The utility of ascertaining strength after 28 days is often questioned since by this time considerable concrete would have been placed and work may have progressed. It is then rather too late for remedial measures. It is therefore of tremendous advantage to predict 28 days strength within a few hours of casting the concrete so that, we have a good idea about the strength of the concrete.
The rate of gain of strength of concrete depends on the reaction rate of cement and additions with water (Hydration). In common with all chemical reactions, the rate of reaction depends on reaction of temp. Higher reaction temperature gives higher rate of reaction e.g. the concrete gains strength more rapidly when its temp. is higher. Accelerated curing is the process by which the temperature of the concrete is raised artificially by applying external heat to speed up the rate of gain in strength.
The test method covers procedures for curing test specimens of concrete stored under conditions intended to accelerate the development of strength. The procedures are: Procedure A- Warm Water Method, Procedure B-Boiling Water Method
General Description & Specification: Accelerated Curing Tank having capacity to accommodate 6/12/18 Concrete Cubes of 150mm size with a facility for accelerated curing by Boiling water method up to temperature range : 100 +/- 2 deg.C as per IS standard IS : 9013. Also it will have capacity for curing by warm water method at temperature 55 +/- 2 deg.C
Tank will consist of a rectangular double walled metal cabinet, inside lined with stainless steel, outer powder coated. Easily replaceable high Wattage heaters are mounted in side the chamber. A slow speed stirrer is provided to circulate water inside the chamber to maintain the uniform temperature of water. A strong stainless steel perforated platform is provided for keeping the cubes and also have a lid with lifting handle to cover the chamber.
The temperature is indicated and controlled by a DIGITAL auto tuning PID Temp. Controller with soak timer to control the duration of heating and then to shut down the system without manual attendance. The front panel will have power supply indicating lamp, control action indication lamp and one main switch. Suitable for operation on 220 V, 50 Hz single phase, AC supply or 440 V 50 Hz, three phase AC supply, for bigger size of curing tank.
Optional Accessories Rubber hand Gloves. Spare Heaters. Low water Level cut off device to safeguard heaters against low water level burn out In built refrigeration system for curing at 27 deg C
Recommended Accessories & Consumbles The following accessories and consumables are not part of the standard supply and are mandatory for the testing work
Also Available
Accelerated Curing Autoclave : By Steam Pressure
Accelerated Curing Drier : By Dry Heat
View Complete Details

Cube Mould

Introduction Cubes of fresh concrete are made to test a variety of properties on the eventually cured and hardened concrete. Fresh concrete is subjected to a standard compaction regime in the cube mould and is then normally initially cured under specific laboratory conditions. The moulds are manufactured, subject to tight dimensional, hardness, square ness and surface finish requirements.
General Description and specifications Complete with base plate. The faces of the mould are machined flat to +/- 0.02mm accuracy and finished to within +/- 0.2mm of specified dimensions. Material for construction of moulds is Cast Iron or Mild steel. The moulds are stout enough to prevent distortion and facilitate the removal of the moulded specimen without damage. The Moulds are so machined that when they are assembled ready for use, the dimensions and internal faces are accurate within the specified limits. Internal faces of the moulds are smooth.
The base plate is attached to the mould by cleats .The parts of the mould, when assembled, are positively and rigidly held together during filling, subsequent handling and vibration where applicable.
SIZES AVAILABLE : 50MM/ 100MM/ 150MM
Optional Accessory As per IS : 10086-1982, The cube mould is so constructed so as to facilitate separation into two parts. The mass of the mould together with the base plate will be 2.8 +/- 0.2 kg. Material for construction of these moulds is mild steel.
CUBE MOULD 7.06 CMS(FOR CEMENT MORTAR) SPANNER FOR DEMOULDING AND MOULDING, TAMPING ROD WITH SAUQRE FACE.
BEAM MOULDS For casting concrete specimens for flexural tests. The mould is made of 4 plates assembled together. Each mould with base plate, made of Mild Stee
View Complete Details

CYLINDRICAL MOLDS

ntroduction
  • 10cm x 20cm Made of Cast Iron with base plate
  • 15cm x 30cm Made of Cast Iron - with base plate
View Complete Details

Extensometer

Introduction The unit consists of two movable frames pivoted at one end. The lateral extensometer is fixed to the specimen with the help of tightening screws. The lateral extension is indicated on a dial gauge of 0.002 mm x 12 mm travel. The extension is magnified 2.5 times and the dial gauge readings are to be divided by 2.5 to get the exact readings. A spacer strip is provided to initially set the dial gauge and can be removed after initial setting. Supplied in a wooden carrying case.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us