Our Products
Power Supply System
2 Products availableTesting Equipment
2 Products availableMeasuring Instruments & Equipment
2 Products availableCalibrators
1 Products availableRefractometer
1 Products availableEthernet Device
1 Products availableLeading Manufacturer, Supplier & Retailer of Network Analyzer, Programmable Converter, Spectrum Analyzers, Vector Network Analyzer and Low Noise Triaxial Measurement Cable.
regenerative, full four quadrant source / sink ac power source, including dc source, power range : 30 kva up to mva range
.
Additional Information:
Payment Terms :
Packaging Details : Wooden Box
Delivery Time : 14 Weeks
product highlight
product features
Additional Information:
Packaging Details : What in package
KC901K *1
User manual *1
Calibration certification *1
DC adapter *1
Strap *1
Delivery Time : 6~12 Week
Make: Omicron-Lab
Model: Bode100
We are the main supplier of this product.
Make : Signal Hound
Model : SA44B
upto 4.4 GHz, EMI, EMC Measurements
Additional Information:
Payment Terms :
DC power supply with integrated linear post-processor, S3R mode
We are the main supplier of this product.
Omicron Lab make Bode-100 Vector Network Analyzer/Impedance Analyzer
8-Channel Broadcast Monitor
The COMM-connect 3024 Broadcast Power Monitor can control up to 8 external RF Measuring heads. The high dynamic range with external couplers and RF measuring heads cover from 1W to 1MW. The Power conversion algorithms handles multi carrier, multi mode, peak, average and RMS signals. The power readout is auto scaled and VSWR can be calculated between any probes. Also the measured and calculated results along with alarms can be shown in the local LCD. The instrument has SNMP support to allow network management. The instrument can be configured for VSWR and Power limits to give alarms. The alarms can be configured to operate relay drivers or isolated Optcouplers. The alarms can also be configured as SNMP traps sending relevant information to the network control center or sending an e-mail. All values are logged and time stamped to a USB stick every minute. The COMM-connect 3024 WEB enabled Power Monitor gives an unlimited number of application to monitor and control the last part of your RF network installation from transmitters to the antenna.
Specifications:
Frequency range:3015 Probe: 470 - 860MHz3016 Probe: 50 - 250MHz3026 Probe: 10 - 2500MHz3020 DDC: depends on variantTemperature range: 0C to +50CPower Supply: 85-264VAC, 50/60Hz
Applications:
Cost effectiveSite monitoringRemote site surveillanceRack mountWeb administrationWide selection of probes
Lightning-Protection-for-copper-Ethernet
RJ45 Surge Protection Device up to 1000 MBit/sProtection Class C2+C1for DIN-Rail and wall mounting
PLANAR R54 is a Vector Reflectometer designed for S11 parameter measurement. It represents an excellent low cost solution for magnitude and phase measurements over the frequency from 85 MHz to 4.2 GHz. With the weight of just 0.25 kg it provides the user with high accuracy measurements and a variety of analysis capabilities in frequency and time domains.
The N1.1 Calibration Kit is used for the calibration of PLANAR TR1300/1 and other vector network analyzers in the frequency range up to 1.5 GHz.
Connector type: NImpedance: 50 OhmMax operating frequency: 1.5 GHz
Calibration kit includes:
SCO501NM.1 OPEN/SHORT calibration standard (male-male) CL501NM.1 LOAD calibration standard (male) CO501NF.1 OPEN calibration standard (female) CS506NF.1 SHORT calibration standard (female) P501NFNF.1 THRU calibration standard (female-female)
Dual Directional Coupler
The 8010 Dual Directional Coupler covers the communication bands from 50MHz to 1000MHz. It has a very good directivity and a high power handling capability. There are 3 different models, each frequency compensated for high accuracy. The integrated RF power heads has a unique dynamic range and very fast response to give possibility to detect any type of modulation and correct reading in a multi carrier environment. Used along with the 3024 Power Monitor there is an unlimited number of applications to monitor and control the last part of your RF network installation from transmitters to the antenna.
Specifications:
Frequency range: 50MHz - 1000MHzDirectivity: > 30dB Power Range: 0 - +63dBmCoupling Range: -35dB to -55dBmTemperature range: 5C to +50C7/16 type connectors available
Applications:
Cost effectiveCell phone NetworksLow Power TV TransmittersUsed with 3024 Power Monitor:SNMP overviewHigh accuracyEarly failure warning:TxAntennaCable
4-Channel Broadcast Monitor
The COMM-connect Entry Level Broadcast Power Monitor type 3025 can control two external RF Measuring heads. The high dynamic range with external couplers and RF measuring heads cover from 1W to 1MW. Equipped with the RMS Probes the Power conversion algorithms handles multi carrier, multi mode signals. With the 3026 Diode base probe the power readout gives good repeatable results. The power readout is auto scaled and VSWR will be calculated between the two probes. The COMM-connect Entry Level Power Monitor gives a number of application to monitor and control the last part of your RF network installation from transmitters to the antenna.
Specifications:
Frequency range:3015 Probe: 470 - 860MHz3016 Probe: 50 - 250MHz3026 Probe: 10 - 2500MHz3020 Probe: depends on variantTemperature range: 0C to +50CPower Supply: 85-264VAC, 50/60Hz
Applications:
Cost effectiveSite monitoringRack mountUSB administrationWide selection of probes
| SP20 PTP Switch 100Mbit/s The RSP20 PTP Switch provides you with a quick and easy solution to realize precise time synchronisation via Ethernet using the precision time protocol according to IEEE 1588-2008. For sure, the RSP20 works perfect with the OTMC 100 PTP Grandmaster Clock and our PTP time converter TICRO 100.Due its design and certifications the RSP20 is the perfect choice, to build up PTP time synchronization networks in electric power substations, as well as industrial and laboratory environments. Due its design and certifications the RSP20 is the perfect choice, to build up PTP time synchronization networks in electric power substations, as well as industrial and laboratory environments. The RSP 20 offers the following features:
Approvals & certifications:
The delivery includes:
Technical data sheet: RSP20 Switch Technical data (96.99 kB) Techical data sheet |
The PMR Power Meter is a very versatile instrument covering most of the PMR bands available. The PMR Power Meter is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The PMR Power Meter instrument is small, handy and light weight battery operated with more than 5 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.
Specifications:
Frequency range: 30MHz - 500MHzVSWR: < 1.05:150Ohms N Female connectorPower Range: 1.5mW to 100WDisplay resolution: 128x64 pixelsCalibration stored in EEPROMUSB Serial device (B type)Operation time: > 5 hours
Applications:
Fast and cost effectiveHandheldLight weightRugged designGraphical swept analysisStore sweeps on memory stick
Handheld Analyzer carrying kit
The COMM-connect Handheld Analyzer carrying kit provides the perfect companion to your handheld analyzer instrument. The kit contains a carrying pouch, wall charger & the most common coax adapters.
Contents:
Carrying pouchCar adapterWall adapterCoax adapters
Specifications:
Frequency range: 30Mhz - 3GHzPouch material: LeatherTemperature range: 0C to +60CHousing: AluminiumSize: 190x110x50mmCoax Adapter types:N male to FME maleN male to BNC femaleN male to TNC femaleN male to mini UHF female
The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.
Applications:
Fast and cost effectiveHandheldLight weightRugged designGraphical swept analysisStore sweeps on memory stick
We are offering t3 innovation, cable tester. spread spectrum time domain reflectometery (sstdr) technology is used. works on either energized or unenergized cables. it can monitor live cables for intermittent conditions and used for telecommunication line analyzer. accuracy to finding fault is better than 1%. t3 products are used to test and speed certifies the data-carrying capabilities of ethernet network cables up to 1 gbps. the device is capable of finding faults (opens, shorts, arc faults) up to 600 volts. it also used to identify, monitor, and troubleshoot lan issues associated with physical layer and link conditions in the network. maximum range: 12, 000 ft (3, 657m). interface: micro usb and sd cards.
The SafeOne is a RF Safety Monitor covering the requirements set forth in WHO ICNIRP specifications. It has a very wide frequency range covering 30MHz to 10GHz, which makes it suitable for use in almost all antenna installations. Due to the innovative lightweight design, technicians can wear this at all times, without the need to constantly be observant of the state of the instrument. The SafeOne is powered with standard batteries, with 250 days of continuous operation.
Specifications:
Frequency range: 10MHz - 10GHzProfessional limit: 10W/m2Public limit: 2W/m2Temperature range: -10C to +40CCurrent consumption: 110uAhBattery type: 2xAAAOperation time: > 250 daysWeight: < 90g incl. batteries
Applications:
Cost effectiveBelt clipLight weightRugged designRadiation displayPersonal safety