Our Products
Features
Quench fluid supply systems are used to supply single or tandem mechanical seals. They act as a convenient fluid reservoir. The exchange of fluid takes place by the thermosiphon principle or by forced circulation, e.g. with a pumping screw. The QFT1000 is made of transparent polyethylene, complete with clips made of stainless steel. The QFT1000 is resistant to water, glycerine, glycols and methanol; not resistant to mineral oils and toluene.
Supply of mechanical seal based on API 682 / ISO 21049, Plan 51.
Advantages
Recommended applications
Functional description
Quench fluid systems are employed:
Notes
Install the quench fluid tank approx. 1 … 2 m (3.3 … 6.6 ft) above the mechanical seal. Install connection pipes to the mechanical seal with low flow resistance. Pipes must vent automatically in the direction of the tank. It is imperative that air pockets are prevented. The minimum filling level must always be above the connection socket at the side (in the case of the thermosiphon principle). Quench fluid systems can be operated in two different modes.
Features
With the EagleBurgmann TS1016 thermosiphon system it is possible to supply buffer/barrier fluid to double and tandem mechanical seals for a broad range of applications. The TS1016 thermosiphon vessel is available in 2 standard sizes with flat ends, sight-glasses for level monitoring and with or without cooling coil. TS vessels are equipped as standard with all the necessary system connections and brackets. The modular system allows the TS1016 vessels to be combined with a wide range of system components such as, e.g. level switch, circulation pump, hand refill pump, thermometer, base frame, etc.
Circulation based on API 682 / ISO 21 049: Plan 52, Plan 53A
Advantages
Standards and approvals
Recommended applications
Functional description
The TS system performs all the basic functions of a buffer/barrier system for the operation of double seals:
Use compressed air or nitrogen for pressurization.
Description
Item | Description | |
---|---|---|
1 | Buffer/barrier fluid IN (G1/2″) | |
2 | Buffer/barrier fluid OUT (G1/2″) | |
3 | Cooling water IN (pipe 12 x 1.5 mm) | |
4 | Cooling water OUT (pipe 12 x 1.5 mm) | |
5 | Filling connection with cap (G1/2″) | |
6 | Pressure gas connection (1/4″ NPT) | |
7 | Connection for level switch (G2″) | |
8 | Connection for refill unit (G1/8″) | |
9 | Connection for pressure gauge (1/4″ NPT) | |
10 | Bracket for refill unit | |
Dimensions for TS1016/A007 | ||
Values in brackets: TS1016/A003. |