Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Automatic Battery Chargers

Listing ID #72294

  • Supply Type Exporter, Supplier
Preferred Buyer From : All over the world

The Elak Automatic Battery Chargers are designed for precise charging of lead acid, sealed maintenance free, VRLA (valve regulated lead acid) and other batteries. These batteries require a....
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Manufacturer
  • GST No. 04AABCE6729Q1Z8

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The Elak Automatic Battery Chargers are designed for precise charging of lead acid, sealed maintenance free, VRLA (valve regulated lead acid) and other batteries. These batteries require a sophisticated charger to charge them in a precisely regulated fashion specified by the manufacturer to avoid irreversible damage through gassing and shortened service life.
The Elak Automatic charger meets the charging specifications of a wide range of VRLA and RG sealed batteries very accurately. The charger delivers a measured constant current to the battery until the manufacturers specified maximum battery voltage is attained. This voltage is then held constant for a specified period to allow a uniform charge across all the plates. The charger may be left connected indefinitely to a fully charged battery without the fear of over-charging or damage.


Features

  • Constant Current Charging
  • Charges 12V and 24V batteries
  • Controlled at all times by a microprocessor
  • Reverse Polarity & Short Circuit protected
  • Analog ammeter
  • Power Supply Voltage : 230V ~ 50 Hz
  • Charge Curve : WU


Technical Specifications

ModelVoltageCurrentEnd VoltageSize
L x W x H (mm)
Weight (kg)
AC 0112 V5 A14.4 V260 x 260 x 1606.5
AC 0224 V5 A28.8 V260 x 260 x 1607
AC 0312 V
24 V
0 - 5 A
0 - 5 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 1609
AC 0412 V
24 V
0 - 15 A
0 - 10 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 16011
The models AC 03 & AC 04 have 2 end voltages. For charging sealed maintenance free & VRLA batteries the cut-off voltage may be set at 13.8 V and 14.4 V for regular lead acid batteries.







Specifications

Model Voltage Current End Voltage Size
L x W x H (mm)
Weight (kg)
AC 01 12 V 5 A 14.4 V 260 x 260 x 160 6.5
AC 02 24 V 5 A 28.8 V 260 x 260 x 160 7
AC 03 12 V
24 V
0 - 10 A
0 - 5 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 160 9
AC 04 12 V
24 V
0 - 15 A
0 - 10 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 160 11
The models AC 03 & AC 04 have 2 end voltages. For charging sealed maintenance free & VRLA batteries the cut-off voltage may be set at 13.8 V and 14.4 V for regular lead acid batteries.






Product Images

  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers

Company Details close-icon

Elak private limited is an iso 9001:2000 certified company with over 40 years of experience in the manufacture of battery chargers, battery testers, auto electrical test benches, alternator starter testers, battery charge monitors, tyre pressure indicators, etc. Its products are the largest selling brand in the country and are recommended and used by all leading battery and automotive manufacturers.
  • Nature of Business Manufacturer / Exporter / Supplier
  • Number of Employees 50 - 100
  • Year of Establishment 1968
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Automatic Battery Chargers?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Automatic Battery Chargers at Best Price in Chandigarh - ID: 72294 | Elak Private Limited
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Automatic Battery Chargers

Listing ID #72294

  • Supply Type Exporter, Supplier
Preferred Buyer From : All over the world

The Elak Automatic Battery Chargers are designed for precise charging of lead acid, sealed maintenance free, VRLA (valve regulated lead acid) and other batteries. These batteries require a....
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Manufacturer
  • GST No. 04AABCE6729Q1Z8

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The Elak Automatic Battery Chargers are designed for precise charging of lead acid, sealed maintenance free, VRLA (valve regulated lead acid) and other batteries. These batteries require a sophisticated charger to charge them in a precisely regulated fashion specified by the manufacturer to avoid irreversible damage through gassing and shortened service life.
The Elak Automatic charger meets the charging specifications of a wide range of VRLA and RG sealed batteries very accurately. The charger delivers a measured constant current to the battery until the manufacturers specified maximum battery voltage is attained. This voltage is then held constant for a specified period to allow a uniform charge across all the plates. The charger may be left connected indefinitely to a fully charged battery without the fear of over-charging or damage.


Features

  • Constant Current Charging
  • Charges 12V and 24V batteries
  • Controlled at all times by a microprocessor
  • Reverse Polarity & Short Circuit protected
  • Analog ammeter
  • Power Supply Voltage : 230V ~ 50 Hz
  • Charge Curve : WU


Technical Specifications

ModelVoltageCurrentEnd VoltageSize
L x W x H (mm)
Weight (kg)
AC 0112 V5 A14.4 V260 x 260 x 1606.5
AC 0224 V5 A28.8 V260 x 260 x 1607
AC 0312 V
24 V
0 - 5 A
0 - 5 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 1609
AC 0412 V
24 V
0 - 15 A
0 - 10 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 16011
The models AC 03 & AC 04 have 2 end voltages. For charging sealed maintenance free & VRLA batteries the cut-off voltage may be set at 13.8 V and 14.4 V for regular lead acid batteries.







Specifications

Model Voltage Current End Voltage Size
L x W x H (mm)
Weight (kg)
AC 01 12 V 5 A 14.4 V 260 x 260 x 160 6.5
AC 02 24 V 5 A 28.8 V 260 x 260 x 160 7
AC 03 12 V
24 V
0 - 10 A
0 - 5 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 160 9
AC 04 12 V
24 V
0 - 15 A
0 - 10 A
13.8 V / 14.4 V
27.6 V / 28.8 V
340 x 260 x 160 11
The models AC 03 & AC 04 have 2 end voltages. For charging sealed maintenance free & VRLA batteries the cut-off voltage may be set at 13.8 V and 14.4 V for regular lead acid batteries.






Product Images

  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers
  • Automatic Battery Chargers

Company Details close-icon

Elak private limited is an iso 9001:2000 certified company with over 40 years of experience in the manufacture of battery chargers, battery testers, auto electrical test benches, alternator starter testers, battery charge monitors, tyre pressure indicators, etc. Its products are the largest selling brand in the country and are recommended and used by all leading battery and automotive manufacturers.
  • Nature of Business Manufacturer / Exporter / Supplier
  • Number of Employees 50 - 100
  • Year of Establishment 1968
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Automatic Battery Chargers?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice