Post Buy Requirement
Nilshikhaa Infraa India Limited
Indore, Madhya Pradesh, India
Add Review

Other Products / Services #1203102

Aerial Bunched Cables

  • Type Bunched
  • Conductor Material Copper
  • Insulation Material Rubber
  • Conductor Type Standard
  • Jacket PVC
  • Voltage 200-400 Volts

In the ABC system, the insulated aluminum conductors (3 or 4 numbers as required) are twisted around a high strength aluminum alloy bearer wire which covers the main weight and also serves as the earth cum neutral wire.
The phase conductor is not under tension. Due to theft prevention, heights of pole elimination of insulator and associated hardware and the possibility of using small sizes of phase conductors like 16 sq. mm in certain location the overall cost of the ABC lines is practically the same as in conventional overhead lines.
Our AB cables are manufactured as per national and international specifications and as per customer requirements. Due to various customers’ requirements the composition and designation of cables are different. Some designations are given on left side of the table mentioned below.
The first part of the designation refers to the numbers and size of the phase conductor, the middle to the street light conductor (where provided) and last to the bare messenger wire. The sizes shown are the nominal cross sectional areas.

Specification

S. No. Nominal Cross Sectional area of phase Conductor mm2 Nominal Cross Sectional area mm2 Maximum dc Resistance at 200C kn Minimum Breaking Load Kn
1 16 25 1.38 7
2 25 25 1.38 7
3 35 25 1.38 7
4 50 35 0.99 9.8
5 70 50 0.69 14
6 95 70 0.49 19.7

Specification

S. No. Designation
1 1 x 16+25
2 2 x 16+25
3 3 x 16+16+25
4 1 x 25+25
5 3 x 25+16+25
6 3 x 35+25
7 3 x 35+16+25
8 3 x 50+16+35
9 3 x 70+16+50
10 3 x 95+16+70
View Complete Details

Multi Core Flexible Cable

  • Type Flexible
  • Material Copper, PVC
  • Thickness 0.5-1mm, 1.5-2mm
  • Voltage 110V
  • Application Home, Industrial
  • Feature Crack Free, High Ductility, High Tensile Strength
View Complete Details

Substation Erection Services

Between the generating station and consumer, electric power travels through several substations at different voltage levels. These substations are used for stepping up & stepping down the voltage and perform several other important functions. If you are looking for a dependable entity that can undertake your substation erection requirements, then you have landed on the right webpage. We, NIIL based in Indore (Madhya Pradesh, India), have been providing substation erection services since 2009. The company has all the modern resources and techniques to design, plan, estimate and develop the undertaken substation erection work.

View Complete Details

Substation Augmentation Services

The main purpose of a substation is to step down the high voltage electricity so it can be easily supplied to homes and businesses through the distribution lines. And, we are providing substation augmentation services from Indore (Madhya Pradesh, India). Active since 2009, we have been providing effective solutions to meet the client’s requirements. Whether you want to augment the substation in a hilly terrain or in a plain area, we have enough resources to fulfil your requirements with utmost precision. So, contact us anytime.

View Complete Details

Submersible Flat Cable

  • Voltage 1000 V
  • Conductor Material Copper
  • Insulation Material Pvc
  • Conductor Type Solid and stranded
  • AC Voltage Rating: 0.6/1kv
  • Size 4 mm
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. S.Bardhan (Nilshikhaa Infraa India Limited)
  • 39, 40, 41-A, 41-B, 42, 43-A, Electronic Complex, Pardeshipura, Pardesipura, Indore, Madhya Pradesh - 452003
  • Share us via
  • Call 08068051325 Ext. 318
List of Other Products by Nilshikhaa Infraa India Limited from Indore, Madhya Pradesh.
Post Buy Requirement
Nilshikhaa Infraa India Limited
Indore, Madhya Pradesh, India
Add Review

Other Products / Services #1203102

Aerial Bunched Cables

  • Type Bunched
  • Conductor Material Copper
  • Insulation Material Rubber
  • Conductor Type Standard
  • Jacket PVC
  • Voltage 200-400 Volts

In the ABC system, the insulated aluminum conductors (3 or 4 numbers as required) are twisted around a high strength aluminum alloy bearer wire which covers the main weight and also serves as the earth cum neutral wire.
The phase conductor is not under tension. Due to theft prevention, heights of pole elimination of insulator and associated hardware and the possibility of using small sizes of phase conductors like 16 sq. mm in certain location the overall cost of the ABC lines is practically the same as in conventional overhead lines.
Our AB cables are manufactured as per national and international specifications and as per customer requirements. Due to various customers’ requirements the composition and designation of cables are different. Some designations are given on left side of the table mentioned below.
The first part of the designation refers to the numbers and size of the phase conductor, the middle to the street light conductor (where provided) and last to the bare messenger wire. The sizes shown are the nominal cross sectional areas.

Specification

S. No. Nominal Cross Sectional area of phase Conductor mm2 Nominal Cross Sectional area mm2 Maximum dc Resistance at 200C kn Minimum Breaking Load Kn
1 16 25 1.38 7
2 25 25 1.38 7
3 35 25 1.38 7
4 50 35 0.99 9.8
5 70 50 0.69 14
6 95 70 0.49 19.7

Specification

S. No. Designation
1 1 x 16+25
2 2 x 16+25
3 3 x 16+16+25
4 1 x 25+25
5 3 x 25+16+25
6 3 x 35+25
7 3 x 35+16+25
8 3 x 50+16+35
9 3 x 70+16+50
10 3 x 95+16+70
View Complete Details

Multi Core Flexible Cable

  • Type Flexible
  • Material Copper, PVC
  • Thickness 0.5-1mm, 1.5-2mm
  • Voltage 110V
  • Application Home, Industrial
  • Feature Crack Free, High Ductility, High Tensile Strength
View Complete Details

Substation Erection Services

Between the generating station and consumer, electric power travels through several substations at different voltage levels. These substations are used for stepping up & stepping down the voltage and perform several other important functions. If you are looking for a dependable entity that can undertake your substation erection requirements, then you have landed on the right webpage. We, NIIL based in Indore (Madhya Pradesh, India), have been providing substation erection services since 2009. The company has all the modern resources and techniques to design, plan, estimate and develop the undertaken substation erection work.

View Complete Details

Substation Augmentation Services

The main purpose of a substation is to step down the high voltage electricity so it can be easily supplied to homes and businesses through the distribution lines. And, we are providing substation augmentation services from Indore (Madhya Pradesh, India). Active since 2009, we have been providing effective solutions to meet the client’s requirements. Whether you want to augment the substation in a hilly terrain or in a plain area, we have enough resources to fulfil your requirements with utmost precision. So, contact us anytime.

View Complete Details

Submersible Flat Cable

  • Voltage 1000 V
  • Conductor Material Copper
  • Insulation Material Pvc
  • Conductor Type Solid and stranded
  • AC Voltage Rating: 0.6/1kv
  • Size 4 mm
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. S.Bardhan (Nilshikhaa Infraa India Limited)
  • 39, 40, 41-A, 41-B, 42, 43-A, Electronic Complex, Pardeshipura, Pardesipura, Indore, Madhya Pradesh - 452003
  • Share us via
  • Call 08068051325 Ext. 318