Our Products
The rapid OXY cube is a newly developed analyzer for highly precise and matrix-independent oxygen concentration measurement. Oxygen analysis using pyrolytic conversion poses high demands to instrument technology. To guarantee a highly precise and matrix-independent result, pyrolysis temperatures up to 1450 C are necessary.
These extreme analysis conditions can only be fulfilled by rapid OXY cube, which achieves full conversion of sample oxygen to carbon monoxide. Even persistent organic as well as most inorganic substances are digested under these conditions and are detected matrix-independently. In addition, the novel backflush technology guarantees blank-free measurements also of the most difficult samples.
Our improvements in instrument technology lead to oxygen concentration analyses with unprecedented precision (standard deviation
The elements sulfur and nitrogen are found in low concentrations in hydrocarbons such as gasoline, diesel or natural gas. The new trace SN cube continues the success of the vario TRACE S/N liquid injection on the already approved cube platform.
The newly developed autosampler in combination with the time-proven combustion technique makes it an outstanding analyzer for the most sensitive determination of sulfur and nitrogen.
Two complete separate combustion and detection channels are incorporated into one analyzer, sharing just the liquid automatic injector (making two separate injections) and electronic control and processing. This allows the ideal analytical conditions and catalysts to be used for each analysis without any compromise.
It also results in significant cost and space savings compared to two separate analyzers. The methods are according to ASTM D 5453, D 6667, D 4629 and DIN ISO 20846. Trace analysis with safe and fully automatic operation.
Protection of our natural landscapes against pollution and contamination is essential. For our safety as well as other organisms, stable isotope analysis is a useful tool when looking at identifying sources of environmental pollution. Bioaccumulation of harmful compounds is a long term threat to human and animal health, especially in the developing world where regulation is less stringent. Contamination of the local environment by shale gas fracking sites must be constantly evaluated to satisfy new regulations. When such pollutants are detected, it is essential that the source is determined and apportioned to remedy the problem, but also ensure that there is no repeat offence.
EnvirovisION offers advanced sample preparation techniques for exceptional levels of detection ensuring that even low level pollutants can be traced to their original source.