Transformer

1.35 Lakh - 48 Lakh /piece Get Latest Price
  • Min. Order (MOQ) 1 pcs
  • Country of Origin India
  • Certification ISI Certified, ISO 9001:2008 Certified
  • Application Control Panels, Industrial Use, Power Grade
  • Feature Easy To Install, Sturdy Construction, Superior Finish
  • Condition New
  • Output Type Double Phase, Single Phase, Three Phase
  • Frequency 50 Hz, 60 Hz
  • Automatic Grade Automatic, Fully Automatic, Semi Automatic
  • Cooling System Air Cooling, Oil Cooling
  • Warrenty 1year, 2years, 5years
  • Production Power 100-250kw, 250-500kw, 50-100kw, 500-750kw, 750-1000kw

Types of transformers



  1. 10 kVA

  2. 20 kVA

  3. 75kVA

  4. 200kVA

  5. 250kVA(CSS)

  6. 315kVA(OLTC)

  7. 315kVA(OCTC)

  8. 315kVA(CSA)

  9. 350kVA

  10. 630kVA

  11. 400kVA

  12. 400kVA(CSA)

  13. 500kVA(OCTC)

  14. 500kVA(OLTC)

  15. 500kVA(CSS)

  16. 630 kVA (Dry type)

  17. 630kVA(Oil type OLTC)

  18. 630kVA(OCTC)

  19. 800kVA

  20. 800kVA(CCA)

  21. 1000kVA

  22. 1mVA

  23. 1000kVA(CSS)

  24. 1250kVA(OCTC)

  25. 1250KVA(OLTC)

  26. 1600KVA(OCTC)

  27. 1600KVA(OLTC)

  28. 2000KVA(OCTC)

  29. 2000KVA(OLTC)

  30. 2500KVA(OCTC)

  31. 2500KVA(OLTC)

  32. 3600KVA(Solar)

  33. 4200KVA

  34. 4200/415

  35. 5000KVA(OCTC)

  36. 5000KVA(OLTC)

  37. 5MVA

  38. Solar Transformers


View Complete Details

Assembled Cores

540 - 1,010 /Kilogram Get Latest Price
  • Country of Origin India
  • Type Assembled Cylinder Head
  • Certification ISO 9001:2008
  • Packaging Type Box
  • Warranty 1yrs, 3yrs, 5yrs

Basically assembled core we manufacturing based on customer requirement as per specification provided by customer. Our range of Core assembling from 500kVA to 25MVA with full fledged facilities ex: Jiggs, fixtures, Core assembly Table with proper handling equipments. We are skilled knowledge in all type of core assembling as like SOD, GOD, & Various type cutting Arrangements (Overlap & Step-lap)

View Complete Details

Potential Transformers

18,000 - 7 Lakh /piece Get Latest Price
  • Min. Order (MOQ) 1 pc
  • 11 kv
  • 33 kv
  • high voltage 50hz

Additional Information:

Payment Terms : L/C,

Packaging Details : Standard export packaging

Delivery Time : One Week

View Complete Details

Solar Power Components

2,500 - 18,000 /piece Get Latest Price
  • Min. Order (MOQ) 100 pieces
  • Country of Origin India
  • Type Power Components, Poly Crystalline
  • Certification ISI Certified, UL Certified
  • Power Source Electric
  • Coating 0-250 Microns, 250-500 Microns
  • Quality Optimum, Premium
  • Cable Length 1.5 Mtr, 2 Mtr, 3 Mtr
  • Warranty 30 years

all kinds of solar modules available,
1) poly crystalline


2) mono crystalline


3) mono half cut modules


4) bi-facial modules

Additional Information:

Payment Terms : L/C

View Complete Details

Current Transformers

18,000 - 7 Lakh /piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Country of Origin India
  • Certification ISI Certified
  • Phase Three Phase
View Complete Details

Ferrite Toroid Core

275 - 700 /kg Get Latest Price
  • Material CRGO
  • Country of Origin India
  • Brand Name ESPI

They help in transferring electric energy from one circuit to another without the use of any moving parts. The energy is transferred through a shared magnetic field that results in changes in the flow of current from one circuit to the other.

View Complete Details

Transformer Laminations Wound Cores

350 - 670 /Kilogram Get Latest Price
  • Min. Order (MOQ) 100 kgs
  • Country of Origin India
  • Type Transformer Laminations
  • Shape Coil, EI Lamination, Steel Coil, Steel Plate, TL Lamination
  • Certification CE Certified, ISO 9001:2008

The manufacturing of wound cores is a specialized process, which requires a high degree of precision. These cores are manufactured from selected coils of CRGO electrical steel to yield closely controlled electro-magnetic characteristics and dimensional accuracy.

View Complete Details

Core Coil Assembly

3.50 Lakh - 10 Lakh /pieces Get Latest Price
  • Min. Order (MOQ) 1 p
  • Country of Origin India
  • Type Core Assemblies
  • Material CRGO
  • Thickness 0-5mm, 5-10mm
  • Length 0-100cm, 100-200cm
  • Application Transformers
  • Weight 0-1000Gm, 1000-2000Gm, 2000-4000Gm
  • Feature Fine Design, Longer Life, Optimum Quality, Precise
  • Condition New
  • Power 0-2500kVA, 2500-5000kVA
  • Phase Double Phase, Single Phase, Three Phase

The core coil assembly (CCA) is the winding assembly on the core. This is a vital part of the transformer also known as the active part.


The construction of the CCA is significant from the performance point of the transformer. The CCA defines the insulation scheme, cooling, dynamic withstand capability, handling. Insulation scheme is categorized into major and minor insulation. Major insulation addresses the capability to withstand high voltages, isolation of the primary and secondary winding, clearances for voltage withstand. Minor insulation is the turn insulation, joint protection etc. Both the major and minor insulation are equally important for the successful operation of the transformer.


Cooling is essential to prevent the thermal degradation of insulation. This enhances a transformers life. Transformers are cooled by convection or forced cooling. The cooling system is responsible for the free flow of oil in the assembly absorbing the heat generated by the windings and dissipating it. Transformers are designed to optimally excavate the heat from the windings through the gaps in the windings. This helps the transformer maintain the same levels of winding temperature and oil temperature during the loading cycle.


The transformer experiences dynamic forces due to frequent loading and unloading. The sudden loading and withdrawal of load creates a tensile stress on the winding in the form of buckling forces or bursting forces. The construction of the CCA by providing sufficient radial and axial supports prevents the stress from causing any damage to the windings. Clamping of the windings axially is necessary to hold the assembly firmly. Clamping structure of the assembly has supports to route the tap and line terminals. Insulated vertical and horizontal strips of adequate thickness of a frame work to assist the routing of terminals.


The assembly also provides facility to handle for ease of lowering the assembly into the tank and vice-versa.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Swapnil Shrivastava (Frelit Energy Private Limited)
  • 315-318 Lilleria Richmond & Paramount,rnNr. Tulsidham Char Rasta,rnManjalpur, Vadodara - 390011, Gujarat, India
  • Share us via
  • Call 08068659119 Ext. 644
Browse Our Products list of Frelit Energy Private Limited Vadodara, Gujarat
Post Buy Requirement
Frelit Energy Private Limited
Vadodara, Gujarat, India
Verified Add Review

Our Products #11888999

Transformer

1.35 Lakh - 48 Lakh /piece Get Latest Price
  • Min. Order (MOQ) 1 pcs
  • Country of Origin India
  • Certification ISI Certified, ISO 9001:2008 Certified
  • Application Control Panels, Industrial Use, Power Grade
  • Feature Easy To Install, Sturdy Construction, Superior Finish
  • Condition New
  • Output Type Double Phase, Single Phase, Three Phase
  • Frequency 50 Hz, 60 Hz
  • Automatic Grade Automatic, Fully Automatic, Semi Automatic
  • Cooling System Air Cooling, Oil Cooling
  • Warrenty 1year, 2years, 5years
  • Production Power 100-250kw, 250-500kw, 50-100kw, 500-750kw, 750-1000kw

Types of transformers

  1. 10 kVA
  2. 20 kVA
  3. 75kVA
  4. 200kVA
  5. 250kVA(CSS)
  6. 315kVA(OLTC)
  7. 315kVA(OCTC)
  8. 315kVA(CSA)
  9. 350kVA
  10. 630kVA
  11. 400kVA
  12. 400kVA(CSA)
  13. 500kVA(OCTC)
  14. 500kVA(OLTC)
  15. 500kVA(CSS)
  16. 630 kVA (Dry type)
  17. 630kVA(Oil type OLTC)
  18. 630kVA(OCTC)
  19. 800kVA
  20. 800kVA(CCA)
  21. 1000kVA
  22. 1mVA
  23. 1000kVA(CSS)
  24. 1250kVA(OCTC)
  25. 1250KVA(OLTC)
  26. 1600KVA(OCTC)
  27. 1600KVA(OLTC)
  28. 2000KVA(OCTC)
  29. 2000KVA(OLTC)
  30. 2500KVA(OCTC)
  31. 2500KVA(OLTC)
  32. 3600KVA(Solar)
  33. 4200KVA
  34. 4200/415
  35. 5000KVA(OCTC)
  36. 5000KVA(OLTC)
  37. 5MVA
  38. Solar Transformers

View Complete Details

Assembled Cores

540 - 1,010 /Kilogram Get Latest Price
  • Country of Origin India
  • Type Assembled Cylinder Head
  • Certification ISO 9001:2008
  • Packaging Type Box
  • Warranty 1yrs, 3yrs, 5yrs

Basically assembled core we manufacturing based on customer requirement as per specification provided by customer. Our range of Core assembling from 500kVA to 25MVA with full fledged facilities ex: Jiggs, fixtures, Core assembly Table with proper handling equipments. We are skilled knowledge in all type of core assembling as like SOD, GOD, & Various type cutting Arrangements (Overlap & Step-lap)

View Complete Details

Potential Transformers

18,000 - 7 Lakh /piece Get Latest Price
  • Min. Order (MOQ) 1 pc
  • 11 kv
  • 33 kv
  • high voltage 50hz

Additional Information:

Payment Terms : L/C,

Packaging Details : Standard export packaging

Delivery Time : One Week

View Complete Details

Solar Power Components

2,500 - 18,000 /piece Get Latest Price
  • Min. Order (MOQ) 100 pieces
  • Country of Origin India
  • Type Power Components, Poly Crystalline
  • Certification ISI Certified, UL Certified
  • Power Source Electric
  • Coating 0-250 Microns, 250-500 Microns
  • Quality Optimum, Premium
  • Cable Length 1.5 Mtr, 2 Mtr, 3 Mtr
  • Warranty 30 years

all kinds of solar modules available, 1) poly crystalline

2) mono crystalline

3) mono half cut modules

4) bi-facial modules

Additional Information:

Payment Terms : L/C

View Complete Details

Current Transformers

18,000 - 7 Lakh /piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Country of Origin India
  • Certification ISI Certified
  • Phase Three Phase
View Complete Details

Ferrite Toroid Core

275 - 700 /kg Get Latest Price
  • Material CRGO
  • Country of Origin India
  • Brand Name ESPI

They help in transferring electric energy from one circuit to another without the use of any moving parts. The energy is transferred through a shared magnetic field that results in changes in the flow of current from one circuit to the other.

View Complete Details

Transformer Laminations Wound Cores

350 - 670 /Kilogram Get Latest Price
  • Min. Order (MOQ) 100 kgs
  • Country of Origin India
  • Type Transformer Laminations
  • Shape Coil, EI Lamination, Steel Coil, Steel Plate, TL Lamination
  • Certification CE Certified, ISO 9001:2008

The manufacturing of wound cores is a specialized process, which requires a high degree of precision. These cores are manufactured from selected coils of CRGO electrical steel to yield closely controlled electro-magnetic characteristics and dimensional accuracy.

View Complete Details

Core Coil Assembly

3.50 Lakh - 10 Lakh /pieces Get Latest Price
  • Min. Order (MOQ) 1 p
  • Country of Origin India
  • Type Core Assemblies
  • Material CRGO
  • Thickness 0-5mm, 5-10mm
  • Length 0-100cm, 100-200cm
  • Application Transformers
  • Weight 0-1000Gm, 1000-2000Gm, 2000-4000Gm
  • Feature Fine Design, Longer Life, Optimum Quality, Precise
  • Condition New
  • Power 0-2500kVA, 2500-5000kVA
  • Phase Double Phase, Single Phase, Three Phase

The core coil assembly (CCA) is the winding assembly on the core. This is a vital part of the transformer also known as the active part.

The construction of the CCA is significant from the performance point of the transformer. The CCA defines the insulation scheme, cooling, dynamic withstand capability, handling. Insulation scheme is categorized into major and minor insulation. Major insulation addresses the capability to withstand high voltages, isolation of the primary and secondary winding, clearances for voltage withstand. Minor insulation is the turn insulation, joint protection etc. Both the major and minor insulation are equally important for the successful operation of the transformer.

Cooling is essential to prevent the thermal degradation of insulation. This enhances a transformers life. Transformers are cooled by convection or forced cooling. The cooling system is responsible for the free flow of oil in the assembly absorbing the heat generated by the windings and dissipating it. Transformers are designed to optimally excavate the heat from the windings through the gaps in the windings. This helps the transformer maintain the same levels of winding temperature and oil temperature during the loading cycle.

The transformer experiences dynamic forces due to frequent loading and unloading. The sudden loading and withdrawal of load creates a tensile stress on the winding in the form of buckling forces or bursting forces. The construction of the CCA by providing sufficient radial and axial supports prevents the stress from causing any damage to the windings. Clamping of the windings axially is necessary to hold the assembly firmly. Clamping structure of the assembly has supports to route the tap and line terminals. Insulated vertical and horizontal strips of adequate thickness of a frame work to assist the routing of terminals.

The assembly also provides facility to handle for ease of lowering the assembly into the tank and vice-versa.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Swapnil Shrivastava (Frelit Energy Private Limited)
  • 315-318 Lilleria Richmond & Paramount,rnNr. Tulsidham Char Rasta,rnManjalpur, Vadodara - 390011, Gujarat, India
  • Share us via