Delhi, India
Our Products
Our Complete range of products are THOMPSON HIP PROSTHESES STERILE, basic instrument set, SAGITTAL SAW HANDPIECE, BONE CUTTING, DRILLING & REAMING SYSTEM and ADAPTATION PLATE.
Generally indicated in Femoral neck fractures with a shortened femoral neck due to bony resorption Patients with limited femoral neck above the lesser trochanter Displaced fracture of the neck of femur Absence of neck Low or distal neck fracture of femur Osteoporotic fracture with femur neck Fractures secondary to malignancies Bony secondaries-Pathological facture
Dia |
Code |
|||
Standard Stem |
Narrow Stem |
|||
Sterile |
Non Sterile |
Sterile |
Non Sterile |
|
37 |
THP37-SS |
THP37-SN |
THP37-NS |
THP37-NN |
38 |
THP38-SS |
THP38-SN |
THP38-NS |
THP38-NN |
39 |
THP39-SS |
THP39-SN |
THP39-NS |
THP39-NN |
40 |
THP40-SS |
THP40-SN |
THP40-NS |
THP40-NN |
41 |
THP41-SS |
THP41-SN |
THP41-NS |
THP41-NN |
42 |
THP42-SS |
THP42-SN |
THP42-NS |
THP42-NN |
43 |
THP43-SS |
THP43-SN |
THP43-NS |
THP43-NN |
44 |
THP44-SS |
THP44-SN |
THP44-NS |
THP44-NN |
45 |
THP45-SS |
THP45-SN |
THP45-NS |
THP45-NN |
46 |
THP46-SS |
THP46-SN |
THP46-NS |
THP46-NN |
47 |
THP47-SS |
THP47-SN |
THP47-NS |
THP47-NN |
48 |
THP48-SS |
THP48-SN |
THP48-NS |
THP48-NN |
49 |
THP49-SS |
THP49-SN |
THP49-NS |
THP49-NN |
50 |
THP50-SS |
THP50-SN |
THP50-NS |
THP50-NN |
51 |
THP51-SS |
THP51-SN |
THP51-NS |
THP51-NN |
52 |
THP52-SS |
THP52-SN |
THP52-NS |
THP52-NN |
53 |
THP53-SS |
THP53-SN |
THP53-NS |
THP53-NN |
54 |
THP54-SS |
THP54-SN |
THP54-NS |
THP54-NN |
55 |
THP55-SS |
THP55-SN |
THP55-NS |
THP55-NN |
Basic Instrument Set in Graphic case for Screws and Plates for screws with thread diameters of 4.5 and 6.5mm
CODE |
DESCRIPTION |
UNITS |
BTD1130.32 |
Drill Bit 3.2mm diameter |
3 |
BTD1130.45 |
Drill Bit, 4.5mm diameter |
2 |
IBS700 |
Counter Sink |
1 |
IBS775 |
Tap Handle |
1 |
IBS772.45 |
Tap 4.5mm diameter |
2 |
IBS775.65 |
Tap 6.5mm diameter |
1 |
IBS735 |
Tap Sleeve, 3.5mm diameter, also as 3.2mm diameter, drill guide |
1 |
IBS720 |
Insert Drill sleeve 4.5/ 3.2mm diameter |
1 |
IBS765 |
Pointed Drill Guide |
1 |
IBS735.45 |
Tap sleeve, 4.5mm diameter |
1 |
IBS747 |
Hexagonal Screw Driver |
1 |
IBS747 |
Screw Driver Shaft |
1 |
IBS708 |
Depth gauge for large screws |
1 |
REH1004 |
Sharp Hook |
1 |
IBS736 |
Drill Sleeve for semi-tubular plates |
1 |
GOS115 |
Tension Device |
1 |
GOS118 |
Socket Wrench |
1 |
GOS120 |
Combination wrench |
1 |
GOS122 |
DCP neutral and load drill guide, 4.5mm |
1 |
GOS125 |
Bending templates for 5-, 7-, and 9- hole plates |
1 |
Features : Transverse Oscillating blade. Five types of blades. Oscillations 13, 000/min. Weight approx.650 gms. Useful for Plug Cutters, Bone Scoop, Right angled mini blades, sector blades, Trephines. Auto clavable
Features : Driving Unit: - 220 Volts/5 Amp A.C. supply, completely enclosed, Foot Control of on/off and speed. Stand: - Castors for mobility. Can be dismantled & Packed into a Suitcase. Hanging type Driving unit also available on request. Handpieces: - Ergonomical design for comfortable handing. Made of non-corrosive metal, Autoclavable
No. of |
Length |
CODE |
|
S.S. |
Titanium |
||
20 |
100 |
665.09 |
665.09T |
Ideal for graft preparation. Facility for cutting strip of graft to desired length. Tensioning post is ideal for pre-tensioning grafts when using ACL button. Fully autoclavable.
Open and close Sharp edge Used for gracillis graft harvesting. Sizes: 6, 7, 8mm diameter
Specifications: Internal Synchronization White balance range: 3200-10000°K Automatic Gain Control ON/OFF switches to GAIN control mode, mirror image, poor light compensation and digit zooming(twice) function. 1/3"CCD image converter Image converter pixel PAL: 795(H) * 596(V) Horizontal resolving degree , 625 lines Lowest lighting: 0.3Lux(F1.2, 5600K) Degree of Protection: IP 67 Dimensions: L x W x H: (320x300x125)mm Net weight: 6.4 Kg Power supply 230V, AC 50 Hz ± 10% Technical Parameter of Camera Head: Camera head grade :BF Degree of protecting liquid: IP67 Camera head diameter: 25mm Camera head connection cord length: Around 3mm Objective lens worm: Standard C- Mount connector
Ideal system for"Arthroscopy Fluid Management" Irrigation pressure and flow rate electronically controlled Digital displays of flow and pressure ratings. Pre- selectable values for irrigation pressure retained in memeory while the unit is switched off. Autoclavable tube set and easy loading of tube. Filter prevents liquid media to come in contact with sensor. Irrigation pressure: 0 to 200mmHg Liquid flow: 0 to 900 ml/min. Power supply: 230V(AC)/50 Hz ±10%
Strong and rigid Can withstand huge load Tip is rounded and non traumatic. Operating length 12cm, 2mm diameter.
Continuous flow On/Off Inflow/Outflow valve Blunt and sharp Obturators available Operating length of Sheath: 120cm, 5mm diameter Rotatable
Ideal board for graft preparation It has the facility for of cutting strip the graft to the desired length. Tensioning post is ideal for pre-tensioning grafts when using the ACL button Fully autoclavable
Guedel airway is one of our widely used Anaesthesia products. The medical device, oropharyngeal airway or anaesthesia airway, is used to maintain a patent (open) airway. It is used in patients who are unconscious or are on general anaesthesia in which tongue can cause obstruction. GPC produces Anaesthesia Airways in various sizes. The correct size of the Guedel Airway is chosen by measuring against the patient’s head. High quality PVC is used in production of Anaesthesia Airways in size 0-4. These Airways may be sterile or non-sterile.
Microprocessor Controlled X-Ray Operations. Ergonomic Design with user friendly functions. High Brightness I.I, High Sensitivity, CCD CAMERA & TV System with Memory Storage System. Standby for workstation. Cordless Remote. Monitoring System Digital Display for mAs, kVp, Technic, X-Ray ON & Overload Protection. Independent kVp, mA, mAs Techniques for better radiographic fluoroscopic results . Microprocessor based system for accurate time selection for exposure. Automatic Overload Protection with visual & audible indication for longer life of the Tube . Automatic Brightness Control. Single step kVp selection. Single step mAs selection. Illuminated Front Panel for easy selection even in dim lit rooms . Soft Touch Keys for mAs selection, mA selection, Radiography/ Fluoroscopy selection & exposure . Computerized Work Station with the following : Last Image Hold, Pulsed Mode, Live Mode, Recursive Filter, Contrast Enhancement, Negative Image, Zoom both in Horizontal & Vertical Direction, Mirror Images , Upside Down Image etc. Large Data Image Storage Facility both in Frame by Frame mode and in Movie mode. Added CD writer for recording on the CD.
High Frequency Auto Programmable X-Ray Systems Best Suited for Bed Side X-Ray & Trauma Care. Spring Based Counter Balanced Stand for easy mobility from ward to ward within Hospital. Soft Touch Key Pad with Automatic Selection of kVp, mA and mAs for each Body Part. Re programmable options for new selection of kVp, mA and mAs at customer's Place. Microprocessor based X-Ray Exposure Control with Microprocessor based Overload Protection for Better Tube Safety
Parameter |
Item Code: IS1560 |
Item Code: IS1570 |
Item Code: IS1580 |
Tube Current (Max) |
60mA |
100mA |
100mA |
Radiological Ratings |
45-100kVp |
45-100kVp |
45-100kVp |
Power |
2.4kW |
3.5kW |
5.0kW |
Tube Type |
Stationary Anode |
Statiionary Anode |
Rotating Anode |
Power Supply |
230V,AC,5Hz,15 Amps with line regulation of +/-10% Line Resist:<0.4 ohms. |
230V,AC,5Hz,15 Amps with line regulation of +/-10% Line Resist:<0.4 ohms. |
230V,AC,5Hz,15 Amps with line regulation of +/-10% Line Resist:<0.4 ohms. |
Respilife is a unique system that can deliver high flows of Air or Oxygen ranging from 1 to 15 LMP. Clinical studies have proved the usefulness of high flow of gases when warmed at body temperature and humidified up to 99 to 100% relative humidity and delivered through nasal cannula. Heat and Humidity prevent airway water loss, airway cooling, thickened secretions, nasal irritation & bleeding. Respilife allows delivery of breathing gases heated to body temperature & at nearly 100% relative humidity by nasal cannula without drying or cooling the airways, not possible in the conventional bubble humidifiers. Most respiratory diseases of the neonate occur as a result of the immaturity of the premature neonate’s lungs. The respiratory system is underdeveloped and adequate gas exchange does not take place naturally, Thus there is a need for providing external respiratory support. Some of the benefits of using Bubble CPAP: RESPILIFE effectively maintains Functional Residual Capacity (FRC). Most lung diseases that lead to respiratory failure are commonly associated with a reduced FRC. Maintaining FRC is very important to premature neonates, having a greater tendency of airway closure when FRC falls below the closing volume. RESPILIFE helps reduce the infant’s Work of Breathing (WOB). There is a decrease in infant’s minute volume and respiratory rate with RESPILIFE. Chest vibrations are caused by the pressure oscillations from the bubbling. These pressure oscillations are reverberated back into the infant’s airway and may provide an alternative form of gas exchange through the principle of facilitated diffusion. RESPILIFE may reduce the need of intubation and mechanical ventilation. The use of RESPILIFE avoids the need of intubation, thereby reducing the possibility of airway injury, aspirations and secondary infection associated with the use of the ET tube. It further reduces the need of mechanical ventilation that minimizes the possible incidence of barotrauma. RESPILIFE tends to reduce the incidence of Chronic Lung Disease (CLD) RESPILIFE may improve the non-pulmonary outcome. Improved non-pulmonary effects such as the tendency to increase mean weight at 36 weeks corrected gestation, increase mean length and head circumference, reduction time to reach full oral feeds and average length of stay.
LEDs: 10/15 High Power, LEDs (Blue + White Optional) Wavelength: 420-480nm Irradiance : > 80 mw/cm /nm at 45cm Variation in intensity over 6 hours
Sized specifically for hospital beds, the 2-way stretch of these knit sheets keeps patients more comfortable, makes bed making easier, and keeps sheets smooth and wrinkle free. Comfortable 100 percent cotton knit on the surface backed by 100 percent polyester. Never needs ironing. Sheet sets come in white/off-white/standard colours only. Sheets fit hospital bed mattresses up to 36"W x 80"L x 8"D.
Seldingers Needle
Get Best QuoteAutoclave-Pressure Cooker Type
Get Best Quote