My ExportersIndia

For Buyer

For Seller

For Help

Our Product / Services

  1. Fire Extinguisher 13 Products / Services available
  2. Electronic Detectors 6 Products available
  3. CCTV Camera 6 Products available
  4. Security Alarms & Devices 4 Products available
  5. Fire Fighting & Protection 4 Products available
  6. Sensors 3 Products available
  7. Photography Equipment & Supplies 3 Products available
  8. Control Panels 3 Products available
  9. Signs 3 Products available
  10. Heat Protection Wear 2 Products available
  11. Security, Metal & Leak Detectors 2 Products available
  12. Surveillance Equipment 2 Products available
  13. Emergency Lights 1 Products available
  14. Repair & Maintenance Services 1 Services available
  15. Wall Light 1 Products available
  16. Grinders, Drills & Power Tools 1 Products available
  17. Coaching Classes 1 Services available
  18. Fire Alarm System 1 Products available
  19. Magnetic Switch 1 Products available
  20. Computer Monitor 1 Products available
  21. Car Safety Accessories 1 Products available
  22. Relays & Contactors 1 Products available
  23. Fancy Jewellery 1 Products available
  24. Leak Detectors 1 Products available
  25. Security And Inspection Devices 1 Products available
  26. Wireless CCTV Camera 1 Products available
  27. Calibrators And Monitoring Systems 1 Products available
  28. Corded Telephones 1 Products available
  29. Downlights 1 Products available
  30. Digital Video Recorders 1 Products available
  31. Street, Flood & Commercial Lights 1 Products available
  32. LED Lights 1 Products available
  33. Others Products / Services 26 Products / Services available

Products / Services

We offer a complete product range of Curtain Detector, Flood Detector, Wireless Pro Panel System, One Way Key Fob and Short Circuit Isolator

Basic Panel

  • Dimension: (250 x 190 x 44 mm).
  • Humidity: 85% relative humidity, @ 30°C (86°F)
  • Storage Temp. Range: -4°F to 140°F (-20°C to 60°C)
  • Weight: 1050 gms

Contrary to popular belief, most burglaries are not random, unplanned acts. In most cases, the burglar is someone who has observed you over time: a former household help or even your ex-watchman could be a potential threat.

He knows your property, the people in it and in many cases, their routine. As for your valuables, every experienced burglar knows where to find them: drawers, cupboards and safes.

So how can you protect yourself against even the most calculated attack?

With Ceasefires security system you can leave your home confident that a break-in will automatically sound an alarm, activate a response, and inform you via your telephone.

Motion detectors, wired siren, magnetic contacts and curtain detectors alert you the second an intruder breaks in. Flood and smoke detectors alert you in case of flooding and fire. And the central control panel monitors the overall security of your home. This system leaves no corner unguarded.

Number of Zones:29 wireless, 1 hardwired (zone No. 30).
Hardwired Zone Requirements:2.2 k E.O.L. resistance (max. resistance of wires 220 ).
Zone Types:Interior, perimeter, delay 1, delay 2, 24 hours - audible, 24 hours - silent, fire, non-alarm and emergency.
User Codes:8 codes, 4 digits each
Data Retrieval:Status, alarm memory, trouble, event log.
Real Time Clock: The control panel keeps and displays time and date.
Compliance with U.S Standards:Meets FCC Part 15 and Part 68 requirements.
Compliance with European Standards:EN 50131-1 Grade II Class II
EMC Emission:EN 50081-1 1992
RFI:EN55022 1998
EMC Immunity:EN 50082-1 1997
EMC Immunity to Conducted RF:EN6100-4-6 1996
Telephony:Telephony: TBR21 1998
Safety:EN60950+ Am1(93), Am2(93), Am3(95), Am4(97)
Receiver Type:Super-heterodyne, fixed frequency
Receiver Range:600 ft (180 m) in open space
Coding:PowerCode and/or CodeSecure
Power Supply :Plug-in transformer.230 VAC, 50 Hz / 9 VAC, 700 mA or 230 VAC, 50 Hz /9 VAC, 1A.
Current Drain:Approx. 95 mA standby, 500 mA at full load and in alarm.
PGM (auxiliary)
Output Current:100 mA max.
Sounder Output Current with 700 mA Transformer :Internal sounder: 50 mA maxExternal sounder:150 mA max
Sounder Output Current with 1A Transformer:Internal sounder: 50 mA max / External sounder: 350 mA max.
Fuse Rating:0.5 A for siren / sounder circuit protection.
Backup Battery :(provides power for at least 4 hours) Option - 7.2 V Nickel-Metal rechargeable battery pack, 1300 mAh.
Built-in Modem:300 baud, Bell 103 protocol
Data Transfer to Local Computer:Via RS232 serial port
Report Destinations: 2 central stations, 4 private telephones
Reporting Format Options:SIA, Pulse 4/21900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Pulse Rate: 10, 20, 33 and 40 pps programmable
Message to Private Phones:Tone or voice
Message to Pager:PIN No. * Alarm Type * Zone No.
Operating Temp. Range:32F to 120F (0C to 49C)

View Complete Details

One Way Key Fob

  • Dimensions 53.5 X 31.5 X 12.5 MM
  • Weight (including battery) 21 gms
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Battery Life Expectancy 1 year (for typical use)
  • Modulation Ask (ON-OFF keying)
  • Power Supply 12 V alkaline battery


Battery Supervision

Good battery - LED lights steadily upon transmission /Low attery - LED flickers upon transmission

Coding

28-bit ID, 4-bit function code and 32-bit rolling code


Transmission Duration

Each button press causes transmission for upto 2 seconds

View Complete Details

Curtain Detector

  • Dimensions (H x W x D) 105 x 35 x 30 mm
  • Weight 60 gms
  • Storage Temperature -20°C to 60°C (-4°F to 140°F).
  • Operating Temperature -10°C to 50°C (14°F to 122°F).
  • Mounting Height 1.8 - 2.4 m (6 - 8 ft).
  • Total Message Length 36 bits.

Detector Type

Dual-element low noise pyroelectric sensor.

Range Settings

Long (6 m), Medium (4 m) and Short (2 m).


Internal Battery

3V Lithium battery


Nominal Battery Capacity

1450 mA/h.


Microprocessor

8-bit, low power CMOS.


Alarm Period

Approx. 3 seconds.


Rearm Timer

Rearms the detector 2 minutes after the last alarm.


Transmission Sequence

3 data bursts at variable intervals within 3 Seconds.


Encoding

24-bit ID, over 16 million possible combinations.

View Complete Details

Flood Detector

  • Weight (including battery) 45gms
  • Dimensions 81 x 23.5x32.5 mm
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Weight of Flood Sensor Cable Approx 60 gms
  • Length of Flood Sensor Cable 3 meters
  • Nominal Battery Capacity 750 mAh

Transmitter's ID Code

24 bit digital word, over 16 million combinations, pulse width modulation.


Overall Message Length

36 bits
Message Repetition

One-shot transmission (default) or once every 3 minutes (selectable)


Power Source

3V Lithium battery


Current Drain

6A STBY, 17mA average in operation (including LED

View Complete Details

Wrist Transmitter

  • Color: Black (Purple button)
  • Weight: 25 Gms
  • Dimensions: 35 mm (1.4 in.).
  • Operating Temperature: 0° to 50°C (32° to 122°F).
  • Nominal Battery Capacity: 150 mAh
  • Power Supply: 3-volt Lithium cell

Modulation

ASK (ON-OFF keying)


Transmitter ID

24-bit digital word, over 16 million possible code combinations, pulse width modulation.


Total Message Length 36 bits

Minimum Transmit Duration2 sec
Power Supply:3-volt Lithium cell

View Complete Details

Wireless Pro Panel System

  • Availability 1600 g ms
  • Dimension 285 x 215 x 55 mm
  • Humidity 85% relative humidity, @ 30°C (86°F)
  • Storage Temp. Range -4°F to 140°F (-20°C to 60°C)
  • Operating Temp. Range 14°F to 120°F (-10°C to 49°C)
  • Message to Private Phones Tone or voice

Zones Number:28 wireless, 2 hardwired (zones 29 & 30).
Hardwired Zone Requirements:2.2 k E.O.L. resistance (max. resistance of wires 220 ).
Zone Types:Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, nonalarm, emergency, gas, flood, temperature and interior /perimeter.
Display:Single line, Backlit 16-character LCD.
Alarm Types:Silent alarm, siren alarm or sounder (internal) alarm, in accordance with zone attributes.
Siren Signals:Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse. (fire).
Siren (bell) Timeout:Programmable
InternalSounder Output:At least 85 dBA at 10 ft (3 m)
Supervision:Programmable time frame for inactivity alert
Data Retrieval:Status, alarm memory, trouble, event log.
Compliance with U.S. Standards:Meets FCC Part 15 and Part 68 requirements. Ul1637, UL1635, UL1023, UL985, ULC-S545-02, ULC C1023.
Receiver Type:Super-heterodyne, fixed frequency
Receiver Range:600 ft (180 m) in open space
Antenna Type:Spatial diversity
Coding:PowerCode and/or CodeSecure
Power Supply:Internal switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
Maximum Output Ripple:0.05
Current Drain: Approx. 40 mA standby, 1400 mA at full load and in alarm.
Site External Siren Current (EXT):450* mA max @ 10.5 VDC minimum when powered by AC & DC (battery).
Site Internal Siren Current (INT):450* mA max. @ 10.5 VDC minimum when powered by AC & DC (battery)
PGM Output Current:100* mA max.
Wired Detectors (zones 29 & 30)
Total (Sum) Current: 36* mA max.
High Current / Short Circuit Protection: All outputs are protected (automatic reset fuse).
Total Pro Panel output current: 550 mA.

View Complete Details

KEYPAD Control System

  • Nominal Voltage 12 VDC
  • Display LDC graphical display 128 × 64 pixels
  • Display Viewing Area (mm) 60.0 × 32.5
  • Case Colour Light grey
  • Dimensions (mm) 147W × 144H × 29D
View Complete Details

DIN Rail Switch

  • Supply Voltage 230V +10% -15% 50 Hz
  • Supply Current ≤ 20 mA capacitive
  • Making Capacity - 2000 W ( incandescent lamp) - 3 A (motors) - 16 A (resistive loads)
  • EMC Emission A ccording to EN 50081-1
  • EMC Immunity A ccording to EN 50082-1
  • Electrical Safety A ccording to EN 60950 1 and EN 60065
  • Signal Sensitivity 5 mVpp min 50 mVp max at 120 kHz
  • Input Impedance ≥ 180 Ohms (L - N) at 120 kHz
  • Connections S crew type terminals for phase, eutral, switched phase,  
  • Dimensions 81 x 23.5x32.5 mm
  • Ambient Temperature 10° C to + 40° C (operation) - 20° C to + 70° C 
View Complete Details

Video Distributor

  • Video Distribution From the junction Points,
  • Operating Voltage From Central Unit,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Multi System Video Power Supply

  • Relay Outputs 3 door lock relay output,
  • Power Supply Switch Mode power supply,
  • Operating Voltage 85-265 VAC (50-60 Hz),
  • Output Voltage 24V DC,
  • Current 3.5A,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Fire Escape Gear

  • Material Mild steel epoxy powder coated to protect against weathering
  • Total Carbohydrate 3 Years
  • Mild Steel Box Size 425mm × 360mm × 140mm
  • Tested Tested to Europen Standard EN 403
  • Fire Blanket Size 1.2m × 1.8m
  • Contents One Pair Fire Blanket and Smoke Hood

While attempting to escape from a fire, there are two things you need protection from. The first is smoke. Toxic and poisonous, smoke inhalation is your first and most critical concern. The second is the fire itself. In order to survive, you must be able to navigate through the fire without sustaining serious burn injuries.

Ceasefires Escape Gear is designed to protect you against these very forces. Each Escape Gear Pack contains two Fire Escape Masks and two Fire Escape Blankets. Together they provide the protection to escape safely from the smoke and fire.

Ceasefire Fire Escape Gear, Mild Steel Box size 425mm 360mm 140mm, Epoxy powder coated to protect it from weathering.

Smoke Hood: Tested to European Standard EN 403: 1993-S, Known to reduce Carbon monoxide, propenl (acrolein), hydrogen chloride, hydrogen cyanide and solid & liquid toxic particles to manageable level for at least 15 minutes, shall withstand temperatures upto 80 Deg, Single Use only.

Fire Blanket Size: 1.2m 1.8m, Used to cover any vessel containing the fire completely, Used to extinguish a clothing fire wrap blanket around victim.

View Complete Details

TWIN FLUID SWIFT

  • Type of system Offered Cylinder Based or Pump Based,
  • Cylinder size 50/100 liters with working pressure of 15 Bar,
  • Extinguisher and propelling agent media Water and Nitrogen,
  • Pump size subjected to design requirement,
  • Cylinder construction material Stainless Steel,
  • Mist micron size 50 to 80 microns,
  • Pipe & Fitting construction material SS 304/316,
  • Types of nozzles CHPS,
  • Water requirement Fine filter water,
  • Design concept Approval NFPA 750,
  • Controls Automatic.
View Complete Details

Conventional Call Point

  • Nominal Operating Resistance 470 ohms,
  • Ingress Protection Rating IP24,
  • Operating Temperature Range –10°C to +50°C,
  • Storage Temperature Range –30°C to +70°C,
  • Maximum Humidity 95% RH - Non Condensing (at 40°C),
  • Colour /Case Material Red / ABS,
  • Weight (g) (Flush Mount) 110 (Surface Mount with Back Box) 161
View Complete Details

Short Circuit Isolator

  • Operating Voltage 17 - 41 VDC,
  • Quiescent Current 50 µA,
  • Current In Short Circuit Maximum Short Circuit Current
  • Operating Temperature Range –10°C to +50°C,
  • Storage Temperature Range –30°C to +60°C,
  • Maximum Humidity 95%RH - Non Condensing (at 40°C),
  • Colour / Case Material Red / ABS,
  • Maximum Number Of Isolators Per Loop 127,
  • Weight (g) 85,
  • Diameter (mm) / Height (mm) 100 / 13,
  • Fixing Centers (mm) 48 ~ 74,
View Complete Details

Powered Output Module

  • Operating Voltage 17 - 31 VDC,
  • Quiescent Current 200µ A (at 41V),
  • Alarm Current 2.3 - 32.3mA,
  • Test Signal Voltage 14 to 30Vd.c,
  • Input Ratings Open Circuit > 100K ohmNormal State - 10 ohm 
  • Short Circuit Operating Temperature Range –10° to +50°C,
  • Storage Temperature Range –30° to +60°C,
  • Colour & Enclosure Material Ivory / ACS,
  • Weight (g) 30
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us