Post Buy Requirement
Hi-Therm Boiler Pvt. Ltd.
Mumbai, Maharashtra, India
Add Review

Other Products / Services #1058750

Forced Draft Blowers

Forced Draft Blowers are generally direct type wherein the casings are fabricated from heavy gauge mild steel sheets and structurals. The impeller is carefully balanced, statically and dynamically to obtain a perfectly vibration free running. The inlet to the blower is generally open to atmosphere but provided with safety cover.

View Complete Details

Hot Air Oven

Hot air ovens are double walled constructed creating air pressurised passage with vertical hot air or cross air flow system for uniform temperature. Hot air ovens & dryers are based on the size and application , oven can be provided with single double hinged doors and trolleys can be designed on the product application.

View Complete Details

Electrical Control Panel

Electrical Control Panel is designed to provide the operations and safe electrical output to the  various motive drives and control operations of the system.
Electrical Control Panel is generally either floor mounted or wall mounted depending upon the applications and site  conditions.
 
Electrical Control Panel is made in 16 swg CRCA sheets duly powder coated and are housed with necessary MCBs,   Power contactors, Overload relays, Terminations, Control contactors, etc which are wired as per  the operating circuit. Rotary Switches, Indicating lamps, Push buttons are placed upfront with  proper labeling for operating the unit. All the input and output are wired with proper suitable lugs  numbered , sleeved and bunched to the various terminals.
Client has to simply connect the input electric supply and the output cables to the various  operating units as per the given termination diagram.
View Complete Details

Oil Preheaters

OIL PREHEATER are used to preheat the fuel oil to the required firing temperature about 100 degree C for furnace oil having Redwood viscosity 1500 scs at 100 degree F. In some cases they are used as “booster heater” to bring the temperature of oil to firing level which was earlier cooled down due to pipeline losses. OIL PREHEATER heater may consist of one or more tubular type immersion heating elements or renewable cartridge type heating elements. The former is suitable for either horizontal or vertical mounting , but the latter is meant for horizontal mounting only. Inlet to the heater may be from bottom , side or top but however outlet connection to the heater should be from top only.

 

Tank OUTFLOW HEATER are used to reduce the viscosity of the furnace oil and thereby enabling an easy flow through pipelines and exerting less load on transfer pumps. OUTFLOW HEATER consist of one or more renewable cartridge type heating elements , thermostat , indicating bulb, dail thermometer , airbreak contactor and matching flage

In OUTFLOW HEATER, only that quantity of oil is heated upto about 50 degree C, Which is flowing out of the tank.

 

 

OIL FILTER is a basket type filter with various mesh sizes suiting various operations. OIL FILTER provides fine filtering to the furnace oil thereby avoid choking of oil nozzles reducing the firing rate and thus a dirtfree oil is supplied to the burner for better atomization and combustion.Two basket filter is combined to give duty cum stand by operation. A Changeover valve  is provided on the filter to select the basket to filter the oil.

 

 

View Complete Details

Multi Gas Cylinder Installation

Non return valves are provided for each individual cylinder in Multi Gas Cylinder Installation, so as to ensure gas from a cylinder travels to process line instead balancing the pressure into coupled cylinders. Apart it also ensure safety in case of pigtail failure.

View Complete Details

Hot Air Dryer

Hot air ovens are double walled constructed creating air pressurised passage with vertical hot air or cross air flow system for uniform temperature. Hot air ovens & dryers are based on the size and application , oven can be provided with single double hinged doors and trolleys can be designed on the product application. Proper insulation is done to avoid heat losses and maintain outside ambient temperature Heat could be generated by means of electric or infrared heaters steam thermic fluid oil gas fired system. Since gaseous fuel provides clean hot air, we can have a direct fired chamber whereas oil fired system should be indirect design.
View Complete Details

Pumping Unit

PUMPING UNIT provides filtered and at preset pressure the light fuel oil like LDO, HSD etc to the furnaces, kilns, ovens, dryers, boilers etc. Presized and completely assembled on a skid, PUMPING UNITS are ready for connection to on-site fuel supply and electrical power. Depending upon process application, simplex and duplex units are available. It comprises of motorized fuel pumps, filters, pressure regulators, valves, gauges etc to form a ring main systems.
View Complete Details

Heat Exchanger

Heat Exchanger take the energy from a hot stream and use it to heat a cooler streamThe shell & tube heat exchangers are the most commonly used type of heat transfer equipment in industries.

A shell & tube Heat Exchangers consists of a bundle of tubes enclosed in cylindrical shell. The ends of the tubes are fitted into tube sheets, which separate the shell side & tube side fluids. Baffles are provided in the shell to direct the fluid flow & support the tubes. The assembly of baffles & tubes is held together by support rods & spacers.

STEAM CUM ELECTRIC HEATING PUMPING FILTERING UNITS AN ENERGY SAVING UNITS in case of steam boiler application-Steam oil preheater working in series with the electric oil preheater.

Hi-Therm Boilers has been a Heat Exchanger Manufacturer for more than two decades and has the experience to provide you with the right solutions.

Diesel Fired Coil Type Heat Exchanger
The Heat Exchanger is designed with an integrated combustion chamber made of M. S. Seamless/ERW boiler tube of adequate size, accurately designed concentric two start helical coil placed in insulated and mild steel shell ensuring optimum heat transfer.
The Photo shown below is a helical coil type 3 pass constructed with vertically down fired automatic diesel burner. In this case the high viscous crude oil is kept in circulation with the help of a circulating pump and the heat is being added to it by the burner.
Satisfactorily Installed & Commissioned at M/s ONGC, Ankleshwar for Maintaining the crude oil Temperature in pumpable condition.
View Complete Details

Electric Thermic Fluid Heater

We are one of the leading Electric Thermic Fluid HeaterManufacturer in India. OurElectric Thermic Fluid Heatersare fully automatic in mode and thus very easy to operate and control. They are offered in both vertical as well as horizontal coil types. Our Thermic fluid heaters arehighly efficient because theelements are totally immersed inthermal fluid and the jacket is fullyinsulated with high density insulation. The ETFHis designed and manufactured using high quality heating elements, precise dimensions in a state-of-the-art manufacturing facility. Our quality control guarantees highest safety and long life span.

The main difference between this heater and a gas or steam boiler is the energy source which used to heat the thermal fluid upto the required temperature. While a gas, oil or diesel boiler has a burner which sprays or injects the fuel, in case of electric thermal fluid heaters, there is no flame as the heat is provided by electrical resistors. Use of low Watt density flanged electric heaters maintain low heat flux densities. The surface area provided is generously sized to keep thermic fluid film temperatures low, which protects the thermic fluid from carbonizing.

Our electric thermal fluid heaters are supplied as a compact unit on a platform containing all equipment components like Heater unit , thermic circulating pump, various isolating valves, its interconnecting piping etc including the expansion tank. These heaters are suitable for upto a maximum temperature of 300 deg centigrade.They are available from a range 6 KW to 120 KW.

View Complete Details

OIL TRANSFER PUMPING UNITS

Furnace oil is best stored in cylindrical tanks either above or below the ground. Generally, the main storage tank is erected above ground when the capacity exceeds 70, 000 litres. For lower capacities, underground storage may be more economical. When erecting a storage tank above ground, remember to maintain safety distances from the surrounding structures, as prescribed by the Explosives Department.

Storage tanks are generally made from welded mild steel plates. The overhead tank should be mounted on concrete blocks, which provide a slight gradient of 1:50 towards the drain valve.

Each of the following fittings has a definite role to play. The Outlet or Draw-Off Pipe should be located at the raised tank end, not less than 15 cms. from the bottom.

The Vent Pipe, of gooseneck type, should be located at the highest point of the tank to facilitate filling by venting air and oil vapour during the filling operation. It should be at least 5 cms. in diameter and provided with a strainer at the outlet.

The Fill-Pipe could be located either at the top or at the bottom of the tank. If located at the top, it must be ensured that the pipe descends almost to the bottom of the tank.When located near the bottom, it is important to position a non-return valve on the line to avoid furnace oil re-entry into the tank-truck on account of back pressure. To avoid leakage of oil during decanting, it is advisable to have a camlock coupling at the filling end so that it fits snugly on the delivery hose.

The Drain Pipe, which is fitted at the lower tank end bottom, is used top periodically remove the accumulated water. It is a difficult task to drain the water and sludge from underground storage tanks. The water and sludge which settle down at the bottom should, however, be removed by a handpump. It would be advantageous to have two suction pipes-one at a lower level and the other at a higher level-so that in case the sludge accumulation is up to the lower point and the suction line chokes up, the alternative line could be put into operation and adequate time would be available to decide upon a time schedule for cleaning the tank.

Furnace oil as delivered may contain dust, dirt, gummy matter and water. During storage for prolonged periods, these tend to form sludge which accumulates in the various dead spaces of the tank, where the oil is not agitated during normal operations of the tank. This results in unsteady flames and clogging of filters. To avoid this, some means of agitation of oil in the tank may be necessary

In addition to the main storage tank(s), industries may have one or a number of day service tanks located in proximity to the units consuming oil.

The principles enumerated earlier for the maintenance of main storage tanks apply here too. The service tank may be sized for a shifts consumption or daily consumption-the choice depends on capacity required, ease of location of tank near the shop, pumping capacity, horse power, etc. certain additional precautions may, however, be taken with respect to service tanks:

a) Service tanks should not be located very near or above furnaces, hot air or process ducts, etc.b) They may be provided with overflow pipes which lead directly below to a sump. As a further refinement, limit switches could be provided to avoid the possibility of oil overflow.c) In gravity feed systems, the difference in height between the service tank and the burners should be at least 10 metres.

Removal of contaminants

Furnace oil should be free from possible contaminants such as dirt, sludge and water before it is finally fed to the combustion system.

Furnace oil arrives at the factory site either in tank lorries by road or by rail. Oil is then decanted into the main storage tank. To prevent the possibility of contaminants such as rags, cotton waste, loose nuts or bolts or screws from entering the system and damaging the pump, position a coarse strainer of 10 mesh size (not more than 3 holes per linear inch) on the entry pipe to the storage tanks. Progressively finer strainers should be provided at various points in the oil supply system to filter away finer contaminants such as external dust and dirt, sludge or free carbon. It is advisable to provide these filters in duplicate to enable one filter to be cleaned while oil supply is maintained through the other. Figure below gives an illustration of the duplex system of arrangement of strainers.

View Complete Details

Hot Air Generator

Salient Features Of Hot Air Generators

Type Direct and Indirect DesignFuel Option- Oil/ Gas / Dual Fuel BurnerFully Automatic Simple And Safe operation.Type Of Burner- On/Off. High/Low and Stepless Modulation through PID Control.Packaged And Compact ModelRobust Construction and Easy Maintenance.

Hot Air Generator is designed for easy and safe operation. By mere turn of switch the unit can be put into operation. Any malfunction is easily and immediately detected and an audio visual alarm system gives a clear cut idea of the fault to the operator for quick rectification. The system is offered as a package comprising of the main chamber alongwith burner, dilution blower, and the control panel. Thus the commissioning time at site is limited to the fuel, electrical and outlet connection.

View Complete Details

HOT AIR OVEN DRYERS

Hi-Therm designs, manufactures and supplies hot air oven & dryers , curing and process heating applications.

Hot air ovens are double walled constructed creating air pressurised passage with vertical hot air or cross air flow system for uniform temperature. Hot air ovens & dryers are based on the size and application , oven can be provided with single / double hinged doors and trolleys can be designed on the product application. Proper insulation is done to avoid heat losses and maintain outside ambient temperature Heat could be generated by means of electric or infrared heaters / steam / thermic fluid / oil / gas fired system. Since gaseous fuel provides clean hot air, we can have a direct fired chamber whereas oil fired system should be indirect design.

The photograpgh shown is a curing oven wherein the heating media is GB series monobloc fully automatic gas burner attached to a heat exchanger. The burner runs on LPG / Piped Natural Gas.

The Heat Exchanger is fitted on the top of the oven to generate the heat and pass the same from heat exchanger to heating chamber. The total fuel consumption varies depending upon the size & the working temperature. The construction of the heat exchanger is done from thick gauge SS304.

Gas burner is a fully automatic model having auto ignition , fuel control and flame sensing system. Gas is supplied through a pressure regulator, pressure gauge and stop valve attached to the burner.

A powerful centrifugal circulating fan provides vertical hot air blowing system with effective heat transfer and uniform temperature to the working area.

The control panel shown houses all the electrical drives for the system. Requisite contactor, relays, switches, indicating lamps etc are prewired to operate the circulating blower and the burner. A digital temperature indicator cum controller operates the system fully automatically under safe condition at the set temperature.

Hot air ovenis completely assembled and prewired with above operating units to facilitate simple and prompt installation on supply.

Various type and size of Hot air ovens are available to suit industry and its application

View Complete Details

Burner Sequence Controller

IRE EYE Gas Burner Sequence Controller

Fire-Eye Gas Burner Sequence Controller is designed for automatic startup of gas burners and flame monitoring in Gas fired furnaces and Ovens, Boilers, Flame screens, Flare gas chimneys, Gas fired kitchen equipments etc using flame electrodes for sensing the gas flame based on flame conduction principle. Fire-Eye provides a high voltage to the flame electrode which is immersed in the flame. The current generated by the electrons flow through from flame to ground is detected for the pressure of flame. In case of flame failure during operation, the ignition is switched ON to ignite gas to confirm gas flow.
FLAME EYE Oil Burner Sequence Controller
Flame-Eye Sequence Controlleris a fully electronic system which enables automatic and safe operation of oil burners. It is a preprogrammed Sequence Controller for the blower, ignition, solenoid valve to ignite the flame along with flame supervision through a photocell. Flame-Eye is must with automatic steam boilers, thermopacks, ovens, dryers, hot air generators, oil burners etc. The Photocell is an L D R encapsulated in as aluminium housing to give a long life trouble free working.
UV Controller
A flame sensor / supervisor suitable for detection of flame in Oil / Gas / Coal fired burners. Highly sensitive only to UV light emitted by flame and not to any refractory glow or day light.
UV controller tube consists of two electrodes sealed in a gas filled quartz envelope. When a voltage is applied across the electrodes and the tube is exposed to UV source like flame, the cathode emits electrons which ionizes the gas in the tube. When the filled gas is ionized the tube becomes conductive and current flows throgh the tube. This says-FLAME ON condition.
View Complete Details

FLAME CONTROLLERS

Principle : The base of fuel burning technology
1 kg of Furnace oil needs 15 kg of Air.
1 kg of LPG Gas needs 29 kg of Air.
Do we maintain this porportion in our daily operations?
Less Air leads to incomplete combustion emitting black smokes whereas excess air not only dilutes the flame but also heat up the stack wasting the fuel input.
Application Of High / Low Flame Controllers : Oil / Gas Fired Furnaces

Salient Features1. Increases the efficiency of the system.2. Continuously monitors the furnace temperature.3. Gradual Inching of firing rates increases the furnace life.4. Quality production and Safe operation.5. Auto control of fuel + Air ratio from min to max working6. Avoids accident during manual settings in a hot accident zone

View Complete Details

Solar Hot Water System

Energy Can Be Changed From One Form To Another, But It Cant Be Created or Destroyed. Solar Energy is the only future hope for a Cleaner and Reliable Energy
India is endowed with rich Natural Solar Energy Resource that People Can Use Which Is Freely Available, Ever Lasting, Environment friendly.
SUN Gives Us Light and Emits Heat.
This Natural Resource Has Been Overlooked By Us Till Date
Because Of Wrong Engineering Of Few Technocrats .
Undoubtedly, The Efficient Methods To Generate Hot Water Is To Install Multiple Flat Plate Solar Collector Panels. But It Also Has The Following Disadvantages Compelling The Buyer For Not Installing It Despite The Indian Government Extending Full Co-operation & The 30% Subsidy On Its Installation Cost .
It Occupies Lots Of Space Which Is A Big Question To The Buyer.
It Also Demands Huge Investment Which When Compared To The Return Outputs Is Very Low.
Lots Of Inter-Connecting Piping Increasing The Chances Of Leakages Which Leads To Corrosion Thus The Necessity For The Replacement & Regular Cleaning Of Multiple Panel Is A Must Increasing The Maintenance Cost.
A Basic Technology Of Power Of A Black Body Absorption Of Heat Energy In An Enclosed Airless Chamber Gives Us A Good Amount Of Transferable Energy To Generate Hot Water . Hot Air . Electric Power . Etc.
View Complete Details

Heating Pumping Unit

Heating Pumping Unit is designed to supply heavy fuel oil like furnace oil, LSHS etc to the burner at a predetermined constant temperature and pressure required for efficient combustion. The principal components are immersion type electric heater, motorized rotary gear oil pump, oil filters, pressure regulators, etc duly interpiped for the operation.

View Complete Details

Hot Air Generators

Hot Air Generator is designed for easy and safe operation. By mere turn of switch the unit can be put into operation. Any malfunction is easily and immediately detected and an audio visual alarm system gives a clear cut idea of the fault to the operator for quick rectification.
View Complete Details

Oil Filters

OIL FILTER is a basket type filter with various mesh sizes suiting various operations. OIL FILTER provides fine filtering to the furnace oil thereby avoid choking of oil nozzles reducing the firing rate and thus a dirtfree oil is supplied to the burner for better atomization and combustion.Two basket filter is combined to give duty cum stand by operation. A Changeover valve is provided on the filter to select the basket to filter the oil.
View Complete Details

Induced Draft Blowers

Induced Draft Blowers are high volumetric but low pressure generally used to handle hot gases or hot air. Below 80 deg cent, the blowers may be direct driven type, but above this they are either belt driven or driven through flexible couplings. Induced Draft Blower can be supplied in M S and S S construction.

View Complete Details

Outflow Heaters

Outflow Heaters is are used to reduce the viscosity of the furnace oil and thereby enabling an easy flow through pipelines and exerting less load on transfer pumps. It consist of one or more renewable cartridge type heating elements , thermostat , indicating bulb, dail thermometer , airbreak contactor and matching flage.
View Complete Details

Industrial Oil Burner

Hi-Therm manufactured Industrial Oil Burner :

Our industrial oil burner series comprises of a burner head, blower, heating pumping unit and an electrical control panel. These burners work on furnace oil / fuel oil, diesel, light oil and heavy oil.

Burner Head :

A series On/Off model are suitable for low firing capacity. Built-in blower along with oil pump with head makes ita compact model enabling it to used on small air heaters, ovens etc wherespace is a constraint.

B Series High /Low / On/ Off Model employ two nozzles and hydraulically operated rapid response of air dampers which regulates the combustion air at each firing rare. A unique system of hinged type maintenance door gives access to the combustion head for inspection and maintenance. Two stage operation automatically bring the industrial oil burnerto low fire status once the desired temperature and pressure is attained and regulates output between the high and low fire set points, depending upon the demands of the system.

The air required for the combustion of fuel oil is provided by the blower. A floor / flange mounted fan provides the air supply for the system. It has a rectangular outlet with a flange, which is drilled for bolting onto the industrial oil burnerhead. The air is controlled through a regulator located on the suction side.

View Complete Details

Electrodes

Our company is counted amongst the foremost manufacturers & exporters, wholesalers and suppliers of Electrodes in India.
View Complete Details

Heating Oil Systems

We are reckoned as reputed manufacturer, exporter and supplier of high quality range of heating oil systems in India.
View Complete Details

Ignition System

Hi-Therm Boilers is a widely prominent and popular name in the field of manufacturing and supplying varied range of ignition system in India.
View Complete Details

Sequence Controller

Hi-Therm Boilers is a widely prominent and popular name in the field of manufacturing and supplying varied range of sequence controller in India.
View Complete Details

Heat Exchangers

Our company is counted amongst the foremost manufacturers & exporters, wholesalers and suppliers of heat exchangers in India.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gunjan Bhardwaj (Hi-Therm Boiler Pvt. Ltd.)
  • A-102, Oshiwara Industrial Estate, New Link Road, Goregaon (W), Mumbai – 400104, Maharashtra
  • Share us via
  • Call 08068051323 Ext. 408