Post Buy Requirement
JI
Gurugram, Haryana, India
Add Review

Our Products #4054700

Dial Thermometer

Round version with stainless steel housing, Stainless steel case for panel-mountingadd-on devices, Stainless steel case with bayonet connection.
View Complete Details

Process Recorder

Vibrant TFT-touchscreen with intuitive operation, Precise control of two processes, Easy-to-use program generator control and program entry, Interfaces: USB host, USB device, Modbus, PROFIBUS DP, PROFINET RT, Ethernet, Process-data recording with tamper-proof data storage, Individual process-screen display with configurable edit boxes, Integrated timer (time-switch contacts) as well as service counter and operating hours counter, Web server for online-visualization via web browser, Password-protected user management, The DICON touch is a two-channel universal process and program controller that displays information using a vibrant TFT color graphics display. The device is operated intuitively by touch. Both controller channels use the tried-and-tested JUMO control algorithm with two possible optimization options. These enable a simple and highly-accurate startup. As a result, multiple zone control, cascade control, or other complex control tasks are possible
View Complete Details

Conductivity Transmitters

Display visualization options: large digits, bar graph, or trend display, Integrated calibration routines: 1, 2, and 3 points, Math and logic module, 12 integrated user languages, Contamination detection can be activated, Pulse input for flow display, Meets all the requirements for ultra-pure water applications in Pharma+Food , Suitable for conductive two and four electrode sensors., Optional boards can be retrofitted, Optional boards can be retrofitted, Data logger with real-time clock .
View Complete Details

Solid State Switches

LCD display with info line, Close mounting possible, Network load optimization through dual energy management, Current limiting, Softstart function, Phase-angle operation, Resistance monitoring and limitation for MoSi2 heating elementsntegrated diagnostic systems, Various field bus interfaces.
View Complete Details

PH - Transmitter

Automatic temperature compensation, Display visualization is selectable: large digits, bar graph, or trend display, Solderless connection technology, Calibration options according to measurand onetwothree point calibration, Activatable impedance measurement, Asymmetrical and symmetrical connection of ph value sensors, Connection option of pH-ISFET sensors through the integrated outputto the voltage supply of the sensor, Selectable languages: English, German, French;additional languages can be added via the setup program, With setup program: easy-to-use programming, plant documentation, download of additional user languages, The device is used to measurecontrol the pH value, the redox voltage, or for NH3 (ammonia) concentration measurement. The function can be changed directly at the device. Depending on the measurand, combination electrodes (e.g. pHredox combination electrodes, gas-sensitive sensors) or separate versions (glassmetal electrodes with separate reference electrode) can be connected. Temperature measurement is used as the second input value which can be performed with such a device as a Pt100Pt1000. As a result, the ph value and NH3 measurands enable automatic temperature compensation.
View Complete Details

Paperless Recorder

LOGOSCREEN nt represents a new generation of JUMO paperless recorders. They are characterized by their modular concept for measured data recording (3 to 18 measuring inputs are possible internally), by their innovative operating concept, as well as by their high standard of safety with regard to access control and protection of the saved data against tampering. In the LOGOSCREEN nt data can be visualized as a measured value curve, as a bar graph, or in alphanumerical form on process screens. High-performance PC programs are available to evaluate archived data and to configure the LOGOSCREEN nt.
View Complete Details

Paddle Wheel Flow Sensor

Simple mounting, For pressures up to PN10 and temperatures up to 70 C, With frequency output, The flow transmitter can be mounted and removed from any pipe diameter (DN15 to DN400) as often as necessary, low control (fresh water, Pump protection, pump control.The paddle-wheel flow sensor is suited for the continuous flow speed measurement of neutral or slightly aggressive liquids carrying a low amount of solid matter. Flow velocities from 0.3 to 10 ms can be measured.The measuring probe provides a frequency pulse signal. Standardized fittings ensure simple insertion of the encoder into DN15 to DN400 tubes.
View Complete Details

Conductivity Sensor

Two-electrode principle, For measuring ranges between 0.05 Scm to 1 mScm, Large selection of process connections, Versions that meet pharmaceutical requirements available with certificate, Shaft diameter only 16 mm.Pure and ultra-pure water field, n Pharmacy, Reverse osmosis plants. measuring cells that conform to the pharmaceutical industry are supplied with a surface roughness of
View Complete Details

Flameproof Enclosure

Parts exposed to the medium out of stainless steel (also available with NiMo alloy, with MoneltitaniumPTFE coating when used with a diaphragm seal) as well as a cavity-free system offer optimum resistance even with aggressive media. The measuring device has a high degree of precision with a deviation from characteristic line of 0.05 % and offers an excellent long-term stability of
View Complete Details

Bimetal Temperature

Electromechanical temperature switch with fixed switching temperatur, m Screw-in spigot similar to Easy installation, No additional auxiliary energy is required for temperature measurement. For this reason, the temperature switch offers a decisive advantage.The use of a bimetal temperature switch does not require capillary lines to be laid. The temperature switch can be directly screw-fitted to become part of the process.The temperature change is transmitted to a bimetal kinematics via the fitting.The temperature switch switches once the switching temperature is reached.
View Complete Details

Temperature Switches

The temperature change is transmitted to a bimetal kinematics via the fitting.The temperature switch switches once the switching temperature is reached.The use of a bimetal temperature switch does not require capillary lines to be laid. The temperature switch can be directly screw-fitted to become part of the process.
View Complete Details

Temperature Measurement Equipment

  • Calibration range -80 to +1100 °C
For monitoring all temperature measurement technology used in industrial applications, building technology, and quality assurance, Traceability of measurement results to national standards, DAkkS (DKD) calibrated test equipment is recognized in Europe and many countries outside of Europe as a means of traceability without a requirement for further information.Precision temperature indicator, Includes Pt100 precision RTD temperature probe, Also available with thermocouple for higher temperatures, Mains operation possible, Measurement results are traceable to national standards. There are growing requirements to increase output and quality as well as reduce process costs for almost all processes are increasing. They go hand in hand with the reduction of measurement uncertainties during process parameter recording. Temperature is one of the most important process variables.
View Complete Details

Mineral Insulated Thermocouple

  • temperatures -200 to +1200 °C
Flexible sheath cable with vibration-resistant measuring insert, Protection tube diameter as of 1.0 mm, Quick response time, Application-specific insertion length, Due to their specific features, mineral-insulated thermocouples are used in chemical plants, power plants, pipelines, engine building, and test rigs.The good thermal transfer between the sheath and the thermocouple enables short response times (t0.5 as of 0.15 s) and excellent measuring accuracy. The vibration-resistant construction guarantees a long operating life. The smallest bending radius is 5 times the outer diameter. With a diameter of 1.0 to 2.0 mm, the minimum insertion length (EL) is 50 mm; with a diameter of 3.0 to 6.0 mm the EL is 100 mm. As of an insertion length of approximately 1000 mm the elements are delivered in a rolled state.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Browse Our Products list of Jumo India Pvt. Ltd. Gurugram, Haryana
Post Buy Requirement
JI
Gurugram, Haryana, India
Add Review

Our Products #4054700

Dial Thermometer

Round version with stainless steel housing, Stainless steel case for panel-mountingadd-on devices, Stainless steel case with bayonet connection.
View Complete Details

Process Recorder

Vibrant TFT-touchscreen with intuitive operation, Precise control of two processes, Easy-to-use program generator control and program entry, Interfaces: USB host, USB device, Modbus, PROFIBUS DP, PROFINET RT, Ethernet, Process-data recording with tamper-proof data storage, Individual process-screen display with configurable edit boxes, Integrated timer (time-switch contacts) as well as service counter and operating hours counter, Web server for online-visualization via web browser, Password-protected user management, The DICON touch is a two-channel universal process and program controller that displays information using a vibrant TFT color graphics display. The device is operated intuitively by touch. Both controller channels use the tried-and-tested JUMO control algorithm with two possible optimization options. These enable a simple and highly-accurate startup. As a result, multiple zone control, cascade control, or other complex control tasks are possible
View Complete Details

Conductivity Transmitters

Display visualization options: large digits, bar graph, or trend display, Integrated calibration routines: 1, 2, and 3 points, Math and logic module, 12 integrated user languages, Contamination detection can be activated, Pulse input for flow display, Meets all the requirements for ultra-pure water applications in Pharma+Food , Suitable for conductive two and four electrode sensors., Optional boards can be retrofitted, Optional boards can be retrofitted, Data logger with real-time clock .
View Complete Details

Solid State Switches

LCD display with info line, Close mounting possible, Network load optimization through dual energy management, Current limiting, Softstart function, Phase-angle operation, Resistance monitoring and limitation for MoSi2 heating elementsntegrated diagnostic systems, Various field bus interfaces.
View Complete Details

PH - Transmitter

Automatic temperature compensation, Display visualization is selectable: large digits, bar graph, or trend display, Solderless connection technology, Calibration options according to measurand onetwothree point calibration, Activatable impedance measurement, Asymmetrical and symmetrical connection of ph value sensors, Connection option of pH-ISFET sensors through the integrated outputto the voltage supply of the sensor, Selectable languages: English, German, French;additional languages can be added via the setup program, With setup program: easy-to-use programming, plant documentation, download of additional user languages, The device is used to measurecontrol the pH value, the redox voltage, or for NH3 (ammonia) concentration measurement. The function can be changed directly at the device. Depending on the measurand, combination electrodes (e.g. pHredox combination electrodes, gas-sensitive sensors) or separate versions (glassmetal electrodes with separate reference electrode) can be connected. Temperature measurement is used as the second input value which can be performed with such a device as a Pt100Pt1000. As a result, the ph value and NH3 measurands enable automatic temperature compensation.
View Complete Details

Paperless Recorder

LOGOSCREEN nt represents a new generation of JUMO paperless recorders. They are characterized by their modular concept for measured data recording (3 to 18 measuring inputs are possible internally), by their innovative operating concept, as well as by their high standard of safety with regard to access control and protection of the saved data against tampering. In the LOGOSCREEN nt data can be visualized as a measured value curve, as a bar graph, or in alphanumerical form on process screens. High-performance PC programs are available to evaluate archived data and to configure the LOGOSCREEN nt.
View Complete Details

Paddle Wheel Flow Sensor

Simple mounting, For pressures up to PN10 and temperatures up to 70 C, With frequency output, The flow transmitter can be mounted and removed from any pipe diameter (DN15 to DN400) as often as necessary, low control (fresh water, Pump protection, pump control.The paddle-wheel flow sensor is suited for the continuous flow speed measurement of neutral or slightly aggressive liquids carrying a low amount of solid matter. Flow velocities from 0.3 to 10 ms can be measured.The measuring probe provides a frequency pulse signal. Standardized fittings ensure simple insertion of the encoder into DN15 to DN400 tubes.
View Complete Details

Conductivity Sensor

Two-electrode principle, For measuring ranges between 0.05 Scm to 1 mScm, Large selection of process connections, Versions that meet pharmaceutical requirements available with certificate, Shaft diameter only 16 mm.Pure and ultra-pure water field, n Pharmacy, Reverse osmosis plants. measuring cells that conform to the pharmaceutical industry are supplied with a surface roughness of
View Complete Details

Flameproof Enclosure

Parts exposed to the medium out of stainless steel (also available with NiMo alloy, with MoneltitaniumPTFE coating when used with a diaphragm seal) as well as a cavity-free system offer optimum resistance even with aggressive media. The measuring device has a high degree of precision with a deviation from characteristic line of 0.05 % and offers an excellent long-term stability of
View Complete Details

Bimetal Temperature

Electromechanical temperature switch with fixed switching temperatur, m Screw-in spigot similar to Easy installation, No additional auxiliary energy is required for temperature measurement. For this reason, the temperature switch offers a decisive advantage.The use of a bimetal temperature switch does not require capillary lines to be laid. The temperature switch can be directly screw-fitted to become part of the process.The temperature change is transmitted to a bimetal kinematics via the fitting.The temperature switch switches once the switching temperature is reached.
View Complete Details

Temperature Switches

The temperature change is transmitted to a bimetal kinematics via the fitting.The temperature switch switches once the switching temperature is reached.The use of a bimetal temperature switch does not require capillary lines to be laid. The temperature switch can be directly screw-fitted to become part of the process.
View Complete Details

Temperature Measurement Equipment

  • Calibration range -80 to +1100 °C
For monitoring all temperature measurement technology used in industrial applications, building technology, and quality assurance, Traceability of measurement results to national standards, DAkkS (DKD) calibrated test equipment is recognized in Europe and many countries outside of Europe as a means of traceability without a requirement for further information.Precision temperature indicator, Includes Pt100 precision RTD temperature probe, Also available with thermocouple for higher temperatures, Mains operation possible, Measurement results are traceable to national standards. There are growing requirements to increase output and quality as well as reduce process costs for almost all processes are increasing. They go hand in hand with the reduction of measurement uncertainties during process parameter recording. Temperature is one of the most important process variables.
View Complete Details

Mineral Insulated Thermocouple

  • temperatures -200 to +1200 °C
Flexible sheath cable with vibration-resistant measuring insert, Protection tube diameter as of 1.0 mm, Quick response time, Application-specific insertion length, Due to their specific features, mineral-insulated thermocouples are used in chemical plants, power plants, pipelines, engine building, and test rigs.The good thermal transfer between the sheath and the thermocouple enables short response times (t0.5 as of 0.15 s) and excellent measuring accuracy. The vibration-resistant construction guarantees a long operating life. The smallest bending radius is 5 times the outer diameter. With a diameter of 1.0 to 2.0 mm, the minimum insertion length (EL) is 50 mm; with a diameter of 3.0 to 6.0 mm the EL is 100 mm. As of an insertion length of approximately 1000 mm the elements are delivered in a rolled state.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us