Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

CF Flow Transmitter

Listing ID #3959514

  • MOQ 100 Piece
  • DN 8..25Female thread G 1/4..G 1 (others available on request)
  • Ambient temperature-20..+70°C
  • Current consumption at restApprox. 20 mA (without load)
  • Nominal widthDN 8..25
  • Supply Type Exporter, Supplier
Preferred Buyer From : All over the world
View More Details
Send Inquiry
Sanand, Ahmedabad, Gujarat
08048787123
  • Member Since 7 Years
  • Nature of Business Retailer
  • GST No. 24CXWPP9877P1ZT

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Pressure resistance PN 10 bar
  • DN 8..25 Female thread G 1/4..G 1 (others available on request)
  • Conformity CE
  • Make Honsberg
  • Current consumption at rest Approx. 20 mA (without load)
  • Ingress protection IP 67
  • Sensor Vortex principle
  • Ambient temperature -20..+70°C
  • Nominal width DN 8..25
  • Electrical connection For round plug connector M12x1, 4-pole
  • Media temperature 0..60°C
  • Supply voltage 10..30 V DC

Details :

  • Flow measurement device using the vortex measurement principle
  • High precision
  • High stability to excessive flow rates
  • No moving parts
  • Rapid installation and removal thanks to clamp fastening
  • Various connections using building block system


Handling and operation : The vortex flow meter requires a run-in length of 5..10 x D in order to achieve its specified accuracy. If deposits are to be expected, sensor and electronics should not be installed underneath. It should be ensured that the sensor is installed in the direction of the flow arrow. If the sensor is to be cleaned, the clamps should be released, and the device removed (the pipe should be pressure-free for this). It should be ensured during cleaning that the oscillating vortex body is not exposed to impact (in the moulded part there is a sensitive piezo-ceramic sensor, which can break).
Accessories :

  • Cable/round plug connector (KB...)
  • Counter EEZ-904
  • Converter/counter OMNI-TA


Download


Download Detail File : Click Here
Interested in this product? Ask for more details & Latest Price from seller
Send Inquiry

Company Details close-icon

We are traders and wholesaler of industrial all types of product and our company established at year 2016.
  • Nature of Business Exporter / Supplier
  • Number of Employees 20 - 50
  • Year of Establishment 2016
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for CF Flow Transmitter?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
CF Flow Transmitter at Best Price in Ahmedabad | J V M Tech Engineering
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

CF Flow Transmitter

Listing ID #3959514

  • MOQ 100 Piece
  • Supply voltage10..30 V DC
  • Ambient temperature-20..+70°C
  • Nominal widthDN 8..25
  • ConformityCE
  • Supply Type Exporter, Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry
  • Member Since 7 Years
  • Nature of Business Retailer
  • GST No. 24CXWPP9877P1ZT

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Nominal width DN 8..25
  • Electrical connection For round plug connector M12x1, 4-pole
  • Ingress protection IP 67
  • Sensor Vortex principle
  • Make Honsberg
  • Current consumption at rest Approx. 20 mA (without load)
  • DN 8..25 Female thread G 1/4..G 1 (others available on request)
  • Pressure resistance PN 10 bar
  • Conformity CE
  • Supply voltage 10..30 V DC
  • Media temperature 0..60°C
  • Ambient temperature -20..+70°C

Details :

  • Flow measurement device using the vortex measurement principle
  • High precision
  • High stability to excessive flow rates
  • No moving parts
  • Rapid installation and removal thanks to clamp fastening
  • Various connections using building block system


Handling and operation : The vortex flow meter requires a run-in length of 5..10 x D in order to achieve its specified accuracy. If deposits are to be expected, sensor and electronics should not be installed underneath. It should be ensured that the sensor is installed in the direction of the flow arrow. If the sensor is to be cleaned, the clamps should be released, and the device removed (the pipe should be pressure-free for this). It should be ensured during cleaning that the oscillating vortex body is not exposed to impact (in the moulded part there is a sensitive piezo-ceramic sensor, which can break).
Accessories :

  • Cable/round plug connector (KB...)
  • Counter EEZ-904
  • Converter/counter OMNI-TA


Download


Download Detail File : Click Here
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We are traders and wholesaler of industrial all types of product and our company established at year 2016.
  • Nature of Business Exporter / Supplier
  • Number of Employees 20 - 50
  • Year of Establishment 2016
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for CF Flow Transmitter?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice