Our Complete range of products are Air Conditioner (Frosty), Air Conditioner (DC-Inverter Based), LCD TV (26 Inch 66 Cms), LCD TV (42 Inch 107 Cms) and Three Phase Power Backup.

Air Conditioner (Frosty)

Kevin's premium air conditioners give you extremely powerful cooling, even in the most adverse temperatures. So when it's blazing hot outside, you can feel the pleasant environment of a hill station right inside your home. These powerful machines provide superior airflow because their rotary compressors are equipped to work efficiently even in harsh conditions. It provides uniform cooling throughout the room and you can even control your room temperature by the three step blowers with the help of a remote control. These air-conditioners also have the higher Energy Efficiency Ratio (EER), which reduces power consumption and lowers your electricity bills.

Technical Specifications

ModelKPS-09CSKPS-12CSKPS-18CSKPS-22CS
Nominal Cooling CapacityBTU/Hr9000120001800022000
Nominal Current-CoolingAmps4.15.88.2310.2
Nominal Power Input-CoolingWatts91612.2117052350
Rated EERW/W2.852.772.732.75
Power SupplyV/Hz/Ph198~264/50/1198~264/50/1198~264/50/1198~264/50/1
Air Flow Ratem3/hr
CFM
500
294
530
312
800
471
1100
471
Noise Level IndoorMed.-db(A)
Low-db(A)
35
32
35
32
39
36
44
40
Remote controlType
Type
LCD
Rotary
LCD
Rotary
LCD
Rotary
LCD
Rotary
FiltersAnti-Bacteria Filter
De-odorising Filter
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Refrigerant-R22R22R22R22
Indoor fan speed H/M/Lrpm1150/1050/9501270/1170/10001060/970/8801330/1230/1150
Outdoor fan Speedrpm860860850850
Indoor Unit Dimensions(WxHxDx)mm770x240x180770x240x180898/280/2021033x313x202
Indoor Unit NetGross WeightKg8/108/1011/1414/17
Out Door Unit Dimension(WxHxDx)mm700x552x256760x552x256820/605/300820x605x300
Outdoor Unit Net/Gross WeightKg3133/3640/4445/9




















View Complete Details

Air Conditioner (DC-Inverter Based)

Kevin air conditioners are the first in India to have DC inverter technology, which digitally controls the capacity supplied by the air-conditioner. It modifies the electricity supply current, frequency or intensity, to ensure a smooth rotation speed. This allows precise matching of the cooling or heating capacities to the actual operating conditions. Once the desired temperature has been reached, the inverter precisely adjusts the capacity to maintain the temperatures to the set point.Some of the benefits of this technologyQuick StartupQuickly achieves and efficiently maintains the desired temperatureExcellent reliability & operation due to auto speed adjustment compressorHigh Energy Savings due to accurate digital controlsSmooth linear rotation of compressor for silent operationElectronic Climate Control - keeps the room temperatures stableHigher Energy Saving Potential - 40-45% of electricity savingsZero Ozone depletion - Uses R410a (Environment Friendly Refrigerant)

Technical Specifications

Model No.KPS-09CHSAKPS-12CHSAKAC-18CHSKAC-24CHS
TypeHeating pumpHeating pumpHeating pumpHeating pump
Control typeRemoteRemoteRemoteRemote
Rated cooling capacityW2600(1200-3050)3700(1840-4480)5200(1600-6000)6400(1650-6800)
Rated heating capacityW3050(1250-4100)4000(1300-4800)4000(1300-4800)6800(1500-7500)
EER for coolingW/W3.553.603.133.15
COP for heatingW/W3.553.603.103.30
Indoor sound pressure level
High
dB(A)37424247
Indoor sound pressure level
Med
dB(A)35404045
Indoor sound pressure level
Low
dB(A)33383842
Outdoor sound pressure leveldB(A)64676970
Electrical Data
Power supply220-240V~/50Hz/1P220-240V~/50Hz/1P220-240V~/50Hz/1P220-240V~/50Hz/1P220-240V~/50Hz/1P
Voltage RangeV155~265155~265155~265155~265
Rated current
Cooling
A3.2(1.4-5.7)4.4(2.2-7.1)7.1(2.6-10.4)8.8(3.1~12.2)
Rated current
Heating
A3.6(1.3-7.3)4.7(1.7-7.6)7.8(2.5-11.3)9.0(2.6~12.6)
Rated input
Cooling
W730(320-1610)1010(460-1580)1640(520-2250)2030(620~2800)
Rated input
Heating
W840(300-1610)1070(400-1670)1800(470-2450)2060(560~2900)
Max current cooling/heatingA4.2/4.75.7/6.110.7/11.613.5/14.6
Max input cooling/heatingW950/10901370/14702600/25602700.2870
Refrigerant System
RefrigerantTypeR410AR410AR410AR410A
CompressorTypeRotaryRotaryRotaryRotary
Fan System
Indoor air circulation cooling/heatingCFM294/312441/471471/500647/647
Indoor fan typeCross FlowCross FlowCross FlowCross Flow
Indoor fan speed H/M/L
Cooling
rpm1220/1050/9001220/1100/9001280/1120/9501400/1240/990
Indoor fan speed H/M/L
Heating
rpm1180/1020/8501130/1000/8501230/1100/9501400/1240/990
Indoor fan speed H/M/L
Dry
rpm900900900900
Indoor fan speed H/M/L
Sleep
rpm900900900900
Outdoor fan typePropeller fanPropeller fanPropeller fanPropeller fan
Outdoor fan speedrpm860860720750
Others
Net dimensions (WxHxD)
Indoor
mm720x240x180898x280x202898x280x2021033x313x202
Net dimensions (WxHxD)
Outdoor
mm760x552x256760x552x256820x605x300902x650x307
Indoor Unit Net / Gross weightkg8/1011/1411/1414/17
Outdoor Unit Net / Gross weightkg33/3632/3742/4656/64