Contact SupplierCounting on our experience in the industry, we have positioned us in the upper echelons of the industry by offering unequaled quality in the form of Extension Modules. Our distribution network allows us to facilitate quick and convenient delivery in a matter of time at your doorstep. They are used for multiplying the output contacts of the basis modules. They also make it possible to contact reinforcement by splitting into multiple control circuits.
Extension modules
Extension modules can be used to multiply the output contacts of the basis modules. Also contact reinforcement by splitting into multiple control circuits is possible.
Delay modules
The emergency-stop of a dangerous movement can be accelerated by a controlled stop operation according to the stop category 1 by allowing motor brake functions or controlled drive speed reduction to run during the cutout delay.
Coupling modules
Coupling modules with positively driven contacts are used to switch safety-related functions as links between logic circuitry and load. The positively driven NC contacts can be used to monitor the closing contacts.
From single function safety modules up to modular multifunction safety systems with field bus connections, designed to protect both man and machine. Sometimes it is not too easy for machine and system manufacturers and users alike to design safety-related circuits using discrete contactor hardware to comply with the abundance of regulations currently in place. To assist them, DOLD offer type-tested safety modules allowing tailored solutions to be installed with respect to functionality and cost.
Advantages
Technology
Extension modules : Compact module with positively-driven safety relays which is triggered by the associated function module (basis module) and monitored via a feedback loop. An extension module can only reach the basis module's safety category acc. to EN 954-1 as a maximum.
Delay modules : Delay-release time-delay relay with or without auxiliary voltage and adjustable or fixed time setting. High long-term stability thanks to digital timer. Two time circuits working independent of each other to implement a cutoff redundancy. Positively driven release contacts.
Coupling modules : Coupling modules feature safety relays with positively driven contacts according to EN 50205. Positive-action is present if the contacts are mechanically linked to each other so that NC and NO contacts can never be closed at the same time. For this it must be ensured that a contact gap of at least 0.5 mm is present over the whole service life, even in fault condition.
Applications
Extension modules : Multiplication of release circuits of a basis module to cut off any number of control circuits in a safety-related manner.
Delay modules : Quick stopping of a dangerous movement of drives with masses.
A typical example are tools rotating with high speed, which still coast after cutoff for a longer time.
Coupling module : Used, for example, for self-monitoring safety circuits, for the adjustment of control and power levels and for switching safety-related functions.