Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Biological Safety Cabinet (MSW-164 A2)

Listing ID #3785215

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

30 % air exhaust 70 % air recirculation HEPA-filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection. ....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1962

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

30 % air exhaust 70 % air recirculation HEPA-filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.  HEPA-filtered downflow air is a portion of mixed downflow and inflow air from a common plenum  Negative Pressure air surrounding all biological contaminated ducts and plenums.  Negative pressure surrounds the work area with double wall plenums for protection. Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and large. The highly efficient HEPA filter maintains the optimum cleanliness and purity. Being equipped with the prefilter, it can extend the life of HEPA filter.
Aerodynamic airflow grills maintain safety and prevents blockage.
U.V and fluorescent interlock available Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue
Sash is counterbalanced for smooth and light weight operation with standard opening of 200mm ±10 mm for easier access to work zone and enhanced user safety.
 
 
 
CLASS-II BIOSAFETY CABINET PROTECTION:
  • Personnel protection from harmful agents used inside the biosafety cabinet.
  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.
  • Environmental protection from contamination of the works, experiment or process from outside contaminants.

 

CLASS-II BIOSAFETY CABINET KEY FEATURES:

 

  • A front access opening with careful maintained inward air flow.
  • HEPA-filtered, vertical, unidirectional airflow within the work area.
  • HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.

 

CLASS-II BIOSAFETY CABINET APPLICATIONS:

Type A2 cabinets are typically used for biosafety levels 1 through 3 and are suitable for work with chemicals, as long as vapors are not hazardous and will not interfere with the work when recirculated, it is acceptable to use an A2 cabinet with a small amount of chemicals when the cabinet is exhausted to the outdoor (Option) for removal of gases.

 

Upper & Front Cover
  • Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

 

Material of Construction
  • Internal Working Chamber is made up of Stainless Steel (SS-304).
  • External Cabinet is fabricated of Cold Rolled Steel Duly powder Coated.

 

Front Window/Sash

Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.

 

Drain Trough with Valve
  • The trough at base is easy to clean and for offloading liquid spillage if any.

 

Decontamination by UV Lamp
  • UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
  • Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
  • Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
  • Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



Class - II Protection From Particulates From Vapors and Gases
Type A2 Personnel, Work Area (Product) and Environment If exhausted to room : not for use with vapors and gases
 If exhausted to facility exhaust system, protects personnel
    If exhausted to a treated facility (VIRUS BRUN OUT) exhaust System protects personnel, the work area and the environment.


Class II Type A2 BIOLOGICAL SAFETY CABINET
MODEL STERIMAX-2(A2) STERIMAX-3(A2) STERIMAX-4(A2) STERIMAX-5(A2) STERIMAX-6(A2)
Internal Dimensions (WxDxH)mm 600x600x600 900x600x600 1200x600x600 1500x600x600 1780x600x600
MOC Internal Working Chamber : Stainless steel (SS-304) Exterior Cabinet : Cold Rolled Steel Duly Powder Coated or Stainless Steel (SS-304)
Pre - Filter Mounted on aluminium frame, of rating 20 microns
Supply / Main Filter HEPA(Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, class 10)
Exhaust Filter HEPA(Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, class 10)
Power Supply 220 V/50 Hz (Standard)
Exhaust Connector (Option) To exhaust potentially contaminated air outside the room
Exhaust Tunnel / Duct ( ?=200 mm) (Option) Available on per running feet basis
Sash Lift Can be lifted and adjusted manually
Sr. No. OPTION        
a) ULPA Filter in lieu of HEPA filter .        
b) Front door made of Toughned Glass (Temepred) in lieu of plexi glass        
c) Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer)        
d) Electronic filter choke alarm (Differential Pressure Monitor)        
e) Microprocessor Controller with door position alarm with Auto Switch off mode for motor blower when door is closed. Digital buzzer timer sounds an audio alarm on completion of sterilizing time of the chamber and the switches off U.V. germicidal tune and automatically switches ON the fluorescent light, alerting the user that the bench is ready for use.        
f) Gas Burner        
g) Virus Burn Out        
h) Heavy Duty exhaust system        
i) Glove ports with gloves        
j) Exhaust ducting per running feet        
k) Digital downflow velocity indicator        
           

Company Details close-icon

A full fledged dedication and consistent effort accompanied by the blessing of elders guided Mr. O.P. Manchanda to establish MAC which with the passage of time made a mark in the scientific journey of his life and to top of all he worked passionately hard, single handedly. A son of a cloth merchant dreamt big and today his own son Rajiv Manchanda has accompanied him to and fulfill his dream. They emerged and how? Our strong foothold in scientific industry is due to the provision and efficiency that is achieved painstakingly at our extremely modern manufacturing unit.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 1962
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Biological Safety Cabinet (MSW-164 A2)?

Quantity
Seller Contact Details
  • Seller Macro Scientific Works Pvt. Ltd.
  • Address GT Karnal Road, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Biological Safety Cabinet (MSW-164 A2) at Best Price in Delhi - ID: 3785215
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Biological Safety Cabinet (MSW-164 A2)

Listing ID #3785215

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

30 % air exhaust 70 % air recirculation HEPA-filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection. ....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1962

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

30 % air exhaust 70 % air recirculation HEPA-filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.  HEPA-filtered downflow air is a portion of mixed downflow and inflow air from a common plenum  Negative Pressure air surrounding all biological contaminated ducts and plenums.  Negative pressure surrounds the work area with double wall plenums for protection. Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and large. The highly efficient HEPA filter maintains the optimum cleanliness and purity. Being equipped with the prefilter, it can extend the life of HEPA filter.
Aerodynamic airflow grills maintain safety and prevents blockage.
U.V and fluorescent interlock available Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue
Sash is counterbalanced for smooth and light weight operation with standard opening of 200mm ±10 mm for easier access to work zone and enhanced user safety.
 
 
 
CLASS-II BIOSAFETY CABINET PROTECTION:
  • Personnel protection from harmful agents used inside the biosafety cabinet.
  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.
  • Environmental protection from contamination of the works, experiment or process from outside contaminants.

 

CLASS-II BIOSAFETY CABINET KEY FEATURES:

 

  • A front access opening with careful maintained inward air flow.
  • HEPA-filtered, vertical, unidirectional airflow within the work area.
  • HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.

 

CLASS-II BIOSAFETY CABINET APPLICATIONS:

Type A2 cabinets are typically used for biosafety levels 1 through 3 and are suitable for work with chemicals, as long as vapors are not hazardous and will not interfere with the work when recirculated, it is acceptable to use an A2 cabinet with a small amount of chemicals when the cabinet is exhausted to the outdoor (Option) for removal of gases.

 

Upper & Front Cover
  • Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

 

Material of Construction
  • Internal Working Chamber is made up of Stainless Steel (SS-304).
  • External Cabinet is fabricated of Cold Rolled Steel Duly powder Coated.

 

Front Window/Sash

Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.

 

Drain Trough with Valve
  • The trough at base is easy to clean and for offloading liquid spillage if any.

 

Decontamination by UV Lamp
  • UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
  • Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
  • Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
  • Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



Class - II Protection From Particulates From Vapors and Gases
Type A2 Personnel, Work Area (Product) and Environment If exhausted to room : not for use with vapors and gases
 If exhausted to facility exhaust system, protects personnel
    If exhausted to a treated facility (VIRUS BRUN OUT) exhaust System protects personnel, the work area and the environment.


Class II Type A2 BIOLOGICAL SAFETY CABINET
MODEL STERIMAX-2(A2) STERIMAX-3(A2) STERIMAX-4(A2) STERIMAX-5(A2) STERIMAX-6(A2)
Internal Dimensions (WxDxH)mm 600x600x600 900x600x600 1200x600x600 1500x600x600 1780x600x600
MOC Internal Working Chamber : Stainless steel (SS-304) Exterior Cabinet : Cold Rolled Steel Duly Powder Coated or Stainless Steel (SS-304)
Pre - Filter Mounted on aluminium frame, of rating 20 microns
Supply / Main Filter HEPA(Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, class 10)
Exhaust Filter HEPA(Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, class 10)
Power Supply 220 V/50 Hz (Standard)
Exhaust Connector (Option) To exhaust potentially contaminated air outside the room
Exhaust Tunnel / Duct ( ?=200 mm) (Option) Available on per running feet basis
Sash Lift Can be lifted and adjusted manually
Sr. No. OPTION        
a) ULPA Filter in lieu of HEPA filter .        
b) Front door made of Toughned Glass (Temepred) in lieu of plexi glass        
c) Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer)        
d) Electronic filter choke alarm (Differential Pressure Monitor)        
e) Microprocessor Controller with door position alarm with Auto Switch off mode for motor blower when door is closed. Digital buzzer timer sounds an audio alarm on completion of sterilizing time of the chamber and the switches off U.V. germicidal tune and automatically switches ON the fluorescent light, alerting the user that the bench is ready for use.        
f) Gas Burner        
g) Virus Burn Out        
h) Heavy Duty exhaust system        
i) Glove ports with gloves        
j) Exhaust ducting per running feet        
k) Digital downflow velocity indicator        
           

Company Details close-icon

A full fledged dedication and consistent effort accompanied by the blessing of elders guided Mr. O.P. Manchanda to establish MAC which with the passage of time made a mark in the scientific journey of his life and to top of all he worked passionately hard, single handedly. A son of a cloth merchant dreamt big and today his own son Rajiv Manchanda has accompanied him to and fulfill his dream. They emerged and how? Our strong foothold in scientific industry is due to the provision and efficiency that is achieved painstakingly at our extremely modern manufacturing unit.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 1962
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Biological Safety Cabinet (MSW-164 A2)?

Quantity
Seller Contact Details
  • Seller Macro Scientific Works Pvt. Ltd.
  • Address GT Karnal Road, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice