My ExportersIndia

For Buyer

For Seller

For Help

Our Product / Services

  1. Valves & Valve Fittings 3 Products available
  2. Business Consultant

    2 Services available
  3. Business Management Consultants

    1 Services available
  4. Material Testing Labs & Services

    1 Services available
  5. Construction Services

    1 Services available
  6. Testing Services

    1 Services available
  7. Heat Exchangers

    1 Products available
  8. Expansion Joints

    1 Products available
  9. Generators, Turbines & Power Plants

    1 Products available
  10. Air Damper

    1 Products available
  11. Others Products / Services 11 Products / Services available

Products / Services

We are leaders in the market for providing best range of Damper AND Gate, Flap Damper, Coal Mill, Turbomachinery Products and Combustion

Thermal Power Plant Machinery

CFD Analysis for Thermal Power PlantDuct AnalysisESP AnalysisBoilerCoal MillAcousticsCyclone SeparatorTurbo machinery Testing for Thermal Power PlantCold Air Velocity TestGD TestNoise TestingDuct Testing
View Complete Details

Rectangular Expansion Joints

With more than 15 Years, MWI is one of the leading suppliers of Fabric and Metallic Expansion joints. Expansion joints are incorporated in pipe and duct system to take up thermal expansion, pressure, vibration and misalignment, there by preventing damage to the pipe work or ducting system. Nowadays Expansion joints are the most important part in industrial and energy plants. For all mediums like air, flue gas, etc they are installed in power plants, gas turbine systems, FGD systems, Pump systems, cement Industries, chemical plants etc.Expansion Joints are devices with at least one bellow, that absorbs movement, stress, noise and vibration to protect pipe or duct fittings. They allow for rigid mounting of pipes in constricted areas and eliminate more complicated means of protecting piping from changes.Expansion joints provide a wide range of deflection capability. A flexible expansion joint may be designed to deflect lateral, axial angular, or torsional stresses, or a combination of any of these.
View Complete Details

Guillotine Gate

It consists of a sliding blade which covers and uncovers the duct opening and seals into its frame in the duct. Various modes of sliding/actuation such as manual, rope & pulley, power screw, pneumatic, hydraulic and integral electric actuator are possible in this configuration.

Features:
  • Low leakage perimeter
  • Low pressure drop across the damper
  • lesser flange to flange space required
  • lesser sealing air requirement in case of 100% sealing efficiency using externally pressurized air
  • various seal design can be incorporated depending on sealing efficiency requirements
  • fewer moving parts and lesser maintenance
View Complete Details

Single Louver Damper

Parallel blades: Adjacent blades rotate in same direction. This type of arrangement is more suitable for flow control in high flow region

Apposed blades: Adjacent blades rotate in opposite direction. This arrangement has a better flow control characteristics (as function of blade position) hence recommended for flow control applications with least disturbances.

View Complete Details

Butterfly Damper

Mechwell offers wide range of Butterfly dampers which provides simple and cost effective method of control and isolation in circular ductwork. Various material grades are available depending on temperature and nature of applications and sizes. In addition, appropriate sealing arrangements can be provided to satisfy the sealing efficiency requirements. This sealing efficiency can be further enhanced to 100% with the addition of twin seals and a sealing air fan. Butterfly dampers can be actuated pneumatically, electrically, by reduction gearbox or by using manual lever.

View Complete Details

Heat Exchanger

In general, heat exchanger design assumes that fluid flow through the bundle of tubes will be evenly distributed. Experience has shown that this is not always true and the consequences of maldistribution in terms of poor performance and increased fouling are often severe.
View Complete Details

Heat Transfer Analysis

We are providing heat transfer analysis. In general, heat exchanger design assumes that fluid flow through the bundle of tubes will be evenly distributed. Experience has shown that this is not always true and the consequences of maldistribution in terms of poor performance and increased fouling are often severe.
View Complete Details

Meshing Consultancy Services

We are providing Meshing Consultancy Services. Meshing is an essential processing step for CFD. It is process of splitting the physical domain into finite element in which the equation governs the physics of flow is solved. Grid or mesh generation is an interface between domain representation and analysis algorithm. The quality of the results is highly dependent on meshing.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us