Our Products
Transmitter Device
2 Products availableTemperature Controller
2 Products availableLeading Manufacturer, Supplier & Retailer of Flow Totaliser, Digital Input Digital Output, Zigbee Converter, Indicators and Converter.
Gas 80 Inputs LCD Display Alarm, Warning, Fault Conditions
Auto Cut-off for faulty GAS Sensors Mutiport Communication
Intelligent RS 485 RS485 MODBUS Menory 2 MB Flash RAM .
The Master/Slave clocks finds application in processes where time synchronization is required. The MASTER clock can be connected to computer on RS232 port which is a serial data transmission. The SLAVE clocks are connected to the master on RS485 port which is a parallel data transmission.
The range available is HOURS: MINUTES: SECONDS or HOURS: MINUTES. The clocks are available in 99 HRS: 99 MINUTES: 99 SECONDS. The state of art microcontroller assures time accuracy of 0.01 %. The clocks in the network displays the same time simultaneously. The maximum slave clocks possible on the network are 32. The Time and calendar configuration can be easily adjusted as per the user requirements. The user friendly GUI works on Windows XP/2000 platform. Master Slave time selection is optional either manual or by PC. Display height available is 2 or 4 with red color and time tick LED indication. The instrument has EMI / RFI filters for harsh electrical environment sustainable capability. The instrument is designed with two/four relay outputs for process control or ALARMS. The power supply given to the device is 230 V / 50 Hz AC. The instrument is housed in MS powder coated enclosure having size 425W * 175H * 100D. Instrument finds application in PHARMACEUTICAL, PROCESS, AUTOMATION, MACHINE TOOLetc
Large Size Display Units 1100D-2 is 4 digit density/process indicator. It is widely used in accurate and quick measuring applications in Petrol Pumps.
| Input | 4-20mA DC |
| Range | 700.0 to 999.9 Kg/M3 (0 to 999.9) |
| Display | 4-digit RED LED (4 digit) |
| Display Size | 2" (50mm ht.) or 2.3" (57.5mm ht.) please specify |
| Ambient Temperature | 0-55 ºC |
| Humidity | 95% RH |
| Principle | Input suitably signal conditioned, amplified, linearised as required and displayed. |
| Power Switch | Provided |
| Power on Indication | Provided |
| Cable Gland | Provided, 3 nos. |
| Mounting | Wall mounting |
| Enclosure | M.S. Powder Coated |
| Supply | 230VAC ± 10%, 50Hz |
setpoint and process both are displayed simultaneously. the process display is 12.5mm height.the setpoint display is 8mm height. the power supply is 90-260 vac.
notes1. on-off control: relay is on upto the set temperature and cuts off at the set point. system temperature will come down and again relay will go on at temperature 2 c below the set point. same function is repeated. adjustable dead band is provided for specific application. time-proportionating control : relay will be on and off in band of 2 c of set-point. on-off : time will adjust as per the heat requirement of the system. of course total time cycle will be of 15 seconds. 2. 4 digit temperature indicator/controller nippon 2020a.3. contact factory for supply volts of 90 - 260 vac & retransmission output
principle : input signal is signal conditioned, linearised and amplified. it is compared with the set point and accordingly relay operates.
| inputs : j, k, r, s, t and other thermocouples, r.t.d's like pt-50, pt-100 (23 wire), 0-1vdc, 4-20 ma. etc. |
| range, indicating : refer table - a |
| accuracy, resolution ambient compensation: automatic |
| setting : by push button - coarse/fine pots or by membrane key - trimpot |
| setting accuracy : better than 0.2% |
| output : relay contacts rated at 230v/6a. |
| control : on-off or time-proportional (refer note on back side) |
| sensor open protection: built-in indicates ' 1', relay cuts-off. |
| ambient temperature: 0-55 c |
| supply : 230 vac 10%, 50 hz standard, 90-260 vac on request. |
| box size : 96 (h) x 96 (w) x 180 (d) or72 (h) x 72 (w) x 110 (d) or48 (h) x 48 (w) x 100 (d) in mm |
| note : 24 vdc for loop power 4-20 ma input on re |
| Model No. | Sensor | Range | Calibration Accuracy | Resolution °C / °F |
| nippon 2020A | Pt-100 (2,3 wire) | -100.0 to 600.0 °C -148.0 to 1112.0 °F | 0.25% | 0.1 |
| nippon 2020 | Pt-100 | -100.0 to 199.9 °C -148.0 to 199.9 °F | 0.25% | 0.1 |
| nippon 2020 | Pt-100 | -100 to 600 °C -148 to 1112 °F | 0.25% | 1 |
| nippon 2020 | Iron/Constantan (J) | -100 to 600 °C -150 to 1112 °F | 0.10% | 1 |
| nippon 2020 | Chromel/Alumel (K) | -80 to 1200 °C -112 to 1999 °F | 0.70% | 1 |
| nippon 2020 | Pt/Rh (R,S) | +900 to 1600 °C +1652 to 1999 °F | 0.50% | 1 |
nippon's pid contollers introduces state of art, truly universal, powerful pid controller with in-house design. the pid series is developed with state of art microcontroller. the robust hardware and software makes the controller very useful in noisy industrial environment. the pid finds applications in industrial ovens, muffle furnaces, b.o.d. incubators, humidity chambers, environmental chambers, sterilizers, blood bank equipments, constant temperature baths, packaging, plastic moulding, thyristors heat controllers, motor controllers, controlled melting, valve control.etc.
Nippon DL 8000 is state - of - art microprocessor based DATA LOGGER. The instrument is very useful where precise DATA LOGGING of process parameters is essential. It finds application in Chemical, Pharmaceutical, Food, Petrochemical, Fertilizer, Heat 'Treatment, Power, Transformer Winding, R&D departments and Laboratories.
| No. Of Channels | 4,8, 12 up to 16 |
| Input | Accepts RTD's (Pt-1OO, Pt-50, Pt-200, Pt-1OOO etc), Thermocouples (J, K, R, S, T), 4 -20 mA, 0 - 5 VDC etc... |
| Scan Rate | Programmable from 1-99 seconds. |
| Linearisation | Software linearised backed by instrumentation OPAMPS. |
| Hold / Skip | Available |
| Sensor Open | Indicates 'OPEN' |
| Display | 4 - digits for temp., 2 - digits for channel no., Bright Seven Segment (0.5"). |
| Alarms | a) Common or individual HIGH / LOW limits with 2-Relays. b) 32 LED's for Alarm Status |
| Noise Immunity | a) EMI / RFI interference is suppressed by MOV's & R-L-C filters. b) "WATCH DOG" guards CPU during power transients. |
| Real Time Clock | Non Volatile Time keeping RAM ensures correct Clock. |
| Data Security | By NVRAM, ensures data retention for 10 years. |
| Supply | 230 VAC ±10%, 50 Hz. |
| Box Size | a) Modular design in 5U size rack, powder coated aluminium enclosure. b) Also available Scanner (96H X 192w) & printer (144H X 144W) separately with D - connection. |
Industrial Printers is now offering "Industrial Printers" Solution. The State-of-art Microcontroller design, sturdy EPSON Printer mechanism, robust power supply, and modular architecture contributes to high performance printing solution. Applications
| Printer Mechanism |
|
| Printing Speed | 1.7 Lines / Sec ± 20% (typical), continuous printing |
| Print Format | a) Number of Columns : 24 (3 Column/Print Solenoid X 8) b) Number of dots : Maximum 144 dots / dot Line |
| Character Size | a) Dot Pitch : Horizontal: 0.33mm; Vertical: 0.37 mm b) 5 x 7 Font : 1.7 mm (W) x 2.6 mm (H) |
| Modes | Reset Mode : Reset push button provided for resetting the printer Test Mode : Provides basic "Test Print" Feed Mode : To Load the paper |
| Paper Specifications | a) Single Ply paper roll. b) Width 57.5 mm ± 0.5 mmX 83 mm or less (outside diameter) X 10 mm or less (inside diameter) c) No gum at either side of roll paper. |
| Interface to outside device | RS232 Communication Connector: For serial printer - D type 25 pin male In parallel printer - D type 25 pin female Mode : Serial mode in CP180SN, MIN180SN, CP190SN Parallel mode in CP180PN, MIN180PN, CP190PN |
| Supply | 90 - 260 VAC, 50 Hz. |
| Noise Immunity | EMI/RFI Interface is suppressed by MOV's & R-L-C Filter |
| Box |
|
| Environment Conditions:Temperature | -10 to 50 °C, Humidity : Upto 90% RH |
| Recommended Accessories | 1. Paper Roll (One built in) (157 mm width X 37 Mtrs) 2. Ribbon (Epson |
Accepts Proxy Encoder Totalizing Mts/Min Indicator, Rate encounter, RPM measurement. 100% Accuracy 4 + 4 digit display 2-set points, 2-Relay outputs 90-260 VAC, 50 Hz 72H X 72W DIN size and 96H X 96W DIN size.
Nippon Technologies was established in 1991 with the objective to design & manufacture INSTRUMENTATION products. In the journey of twelve years range of products delivered have become 'benchmark' in the industry. A milestone was reached in 1997 with introduction of state-of- art data acquisition system The customer acceptance was enormous.
Additional Information:
Payment Terms :
Delivery Time : 1 Week
The costly powder material cannot be filled in the sacks by volume, it requires weight-based measurement.
Here the load-cell is used for precision weight measurement. The load-cell signal is digitized by 16 bit / 24 bit ADC's. The hopper, contains a powder to be filled, has a crew, which is controlled by clutch & brake assembly. The VFD controls the speed of filling.
Thus hardware requires the Analog input & digital outputs along with the timers for continous cycle.
Compressors are integral part of plants and consumes lot of electricity. Efficient process Controls saves electricity.
TEMPERATURE / TIME Based controls is the principle of operation.UN2000 is used in this method. The instrument is designed for single or double stage compressors. The antifridge and capacity control are important temperature points. Compressor is switched ON & OFF considering these points. This leads to optimum use of compressor inturn saving in electricity bill. Also DELAY TIME is introduced to avoid frequent ON/OFF. Once the compressor gets off & if temperature increases above set point it can get ON only after the DELAY TIME. The delay time is also programmable. THE TIME & TEMPERATURE MONITORING AND CONTROL LEADS TO OPTIMUM USE OF COMPRESSORS.
5050-B, 5050 & 5050-6 are unique digital Presettable Counters with and without memory having wide applications in textile Industries for meter counting, Pharmaceutical - chemical - Food Industries for event counting, packing machinaries, machine tool engineering for stroke counting and many other areas where accurate counting is involved.
Instrument accepts signals from Photo Sensors, Proximity Switches, Limit Switches, Contact closures, Encoders, Voltage Pulses . etc. Instrument can work upto 2 KHZ. of switching frequency. The Incoming signal is filtered, conditioned, wave shaped with help of filters and choppers. The signal is fed to Synchronous counter I.C. which drives seven segment display. At the same time signal is compared with set value. At the set point relay change over takes place. The Relay can be operated in Delayed On, Delayed Off, Auto Reset modes as per the application.
| Range | 0-99, 999, 9999, 99 99 99 Counts. |
| INPUTS | Limit Switches, Proximity Switches, Photo Sensors, Encloder,Voltage Pulses, Contact Closures....etc... |
| MAXIMUM FREQUENCY | Upto 2 KHZ. |
| COUNTING ACCURACY | Cent - Percent. |
| DISPLAY | 3, 4 or 6 digit bright Seven Segment display. |
| LIMIT SETTING | By Thumbwheel Switches. |
| LOGIC | Delayed On, Delayed Off, Auto reset, Auto reset with timer. |
| MODE | Count Up. (Count Down on request) |
| OUTPUT | Relay (O.E.N.) Changeover rated at 230 V/6A. |
| SUPPLY | 30 VAC ±10 %, 50 Hz. |
| Box | 96 (H) X 96 (W) X 180 (D), mm DIN size box with modular system. Also available in 72 (H) X 72 (W) X 110 (D) mm |
Nippon Technologies was established in 1991 with the objective to design & manufacture INSTRUMENTATION products. In the journey of twelve years range of products delivered have become 'benchmark' in the industry. A milestone was reached in 1997 with introduction of state-of- art data acquisition system The customer acceptance was enormous.
Nippolog is constantly upgraded as per the requirement of industry. We have invested more than 25 man-years in up gradation of Nippolog.Today Nippolog is flagship product of the company, it consists of SCANNERS, CONVERTORS, MEMORY BANKS & SOFTWARE.If your measurement & data logging application involves a diverse array of sensors or events, located centrally or over large distance, then Nippolog is the answer. Nippolog can become foundation of your measurement & data acquisition. It increases PRODUCTIVITY through accurate measurement, data acquisition, data analysis & data visualiz.
Nippolog- a robust architecture functions reliably even in electrically & environmentally harsh environment. The software periodically aquires data from scanners and presents it in various forms at the user's monitor. Nippolog is interactive and very simple to use. It's features include Graphical Trends, Tabular Listing, Batch-wise data archival, Online Help, and many others. This becomes simplest tool for dozens of uses.
Nippolog finds application in Pharmaceuticals, Bulk Drug, Dyes and Chemicals, Petrochemical, Engineering, Power Plants, Glass, Textiles, Air-Conditioning/ Refrigeration, Test Laboratories and many other industries. There are over One hundred successful installations.
| Input | RTD's, Thermocouples, 0-1 VDC, 4-20mA, Logic Inputs,, |
| No. of Channel | Interfacing up to 256 parameters |
| Trends | Graphical and Tabular display |
| Archival | AAutomatic, Programmable, and Batchwise data Storage |
| Access Mode | Normal User and Super User mode. |
| Communication | RS232 and RS485 |
| Protocol | Proprietory ASCII, MODBUS on request |
Data Export
|
Minimum PC Requirement
|
Humidity Logger is a brainchild of Nippon Technologies. State-of -the-art micro controller design is a high performance solution for various HUMIDITY applications. It accepts two 4-20 mA inputs. One for Humidity and another for Temperature. Generally the signal comes from humidity transmitters. Typical applications
|
Input |
From Humidity/Temperature Transmitter. (Dry / Wet bulb input available on request) |
| Display | 2 sets of (4+4) digit diaplay. Upper for Temperature and lower for Humidity |
| Range | Humidity 0 to 96.0 % RH Temperature -20 to 80.0ºC , depending on type of Transmitter. |
| Resolution | Relative Humidity 0.1 RH Temperature 0.1ºC |
| Output | 2 Relays. A) Humidity Control: One relay for Humidification, second for relay for Dehumidification. B) Temperature Control: One relay for cooling (Comprosessor / Blower), Second relay for Heating (Heater) |
| Control Accuracy | ± 3% for Humidity / ± 0.25% for Temperature |
"NIPPO FLOW" series is designed with help of State-of-art micro controllers. The instruments can measure Flow accurately, it accepts signals, from FLOW TRANSMITTERS and calculates flow rate and also integrates the same. The 4 digit indicator displays the instantaneous flow rate and 10 digit counter displays TOTAL FLOW.
| INPUTS | 4-20 mA, or Volt Pulses. |
| RANGE | Flow Totaliser - 10 digits. Flow Rate - 0-9999 Units (Lit/Min or Kg/Hr or Tons/Hr or M3/Hr) |
| ACCURACY | Cent Percent |
| DISPLAY | 10 digits bright seven segment display for Flow Totaliser. 4 digits bright seven segment display for Flow Rate |
| PARAMETER SETTING | By soft touch, Elegant, Sturdy & user friendly membrane key pads. |
| MEMORY | 10 years NVRAM. |
| COMPUTER INTERFACE | RS232 or RS 485, MODBUS available. |
| SUPPLY | 90-260 VAC, 50 Hz, SMPS |
| AMBIENT CONDITION | Temp 55°C & Relative Humidity 99% |
| RETRANSMISSION | Available • 4-20 mA for Flow rate. • Pulses for Flow Counts. |
| SET POINTS | 2 Nos, Possible for Flow rate & Flow Totaliser. |
| OUTPUT | 2 Relays, rated 230 V / 6 Amp. |
| BOX | 96(H) X 192(W) X 180(D) Din Size box with modular design. Also available in FLAMEPROOF ENCLOSURES For Hazardous application. |
Thermocouple and RTD's Heavy duty designSS 316 / Inconel Sheath Heavy Duty, 14/32 SWG, FG/SS Braided extension cable Heavy Duty Male/ Female quick disconnect connector Widely used in Coast Guard, War Ships & Submarines
The PTXM Series is Multiple Loop Powered Temperature Transmitter. The device supports different input sors RTD PT100 & PT1000 and thermocouples (J type & K type). The selection of input sensor device can be configured through RS845 link from the PC side application.
The PC side application would help the user to configure the device for particular range of input as well as range of current. The application reads the temperature from the device as well. The device transmits the read temperature and current output value to the application.
| Input | Pt-100 thermocouple J & K type. |
| RANGE | For PT 100 -200 to +800. J type 0 to 600o C K type 0 to 1200o C |
| Output | 4-20mA dc current output |
| Accuracy | Linearity Better than ±1 % |
| Supply | 18V to 36V DC supply. |
| Design | Micro Controller based, sturdy and accurate. |
| Operating Temperature | -40o C to + 85o C |
| Fault Detection | Configurable Input short for RTD. Input open for both RTD and Thermocouple. |
| Offset | User adjustable with trimmer potentiometer. |
| Auto Calibration & system Calibration | Provided from PC side application |
| Protection | Reverse Polarity and surge with TVS diode clamp |
NIPPO FLOW" series is designed with help of State-of-art micro controllers. The instruments can measure Flow accurately, it accepts signals, from FLOW TRANSMITTERS and calculates flow rate and also integrates the same. The 4 digit indicator displays the instantaneous flow rate and 10 digit counter displays TOTAL FLOW.
| INPUTS | 4-20 mA, or Volt Pulses. |
| RANGE | Flow Totaliser - 10 digits. Flow Rate - 0-9999 Units (Lit/Min or Kg/Hr or Tons/Hr or M3/Hr) |
| ACCURACY | Cent Percent |
| DISPLAY | 10 digits bright seven segment display for Flow Totaliser. 4 digits bright seven segment display for Flow Rate |
| PARAMETER SETTING | By soft touch, Elegant, Sturdy & user friendly membrane key pads. |
| MEMORY | 10 years NVRAM. |
| COMPUTER INTERFACE | RS232 or RS 485, MODBUS available. |
| SUPPLY | 90-260 VAC, 50 Hz, SMPS |
| AMBIENT CONDITION | Temp 55°C & Relative Humidity 99% |
| RETRANSMISSION | Available • 4-20 mA for Flow rate. • Pulses for Flow Counts. |
| SET POINTS | 2 Nos, Possible for Flow rate & Flow Totaliser. |
| OUTPUT | 2 Relays, rated 230 V / 6 Amp. |
| BOX | 96(H) X 192(W) X 180(D) Din Size box with modular design. Also available in FLAMEPROOF ENCLOSURES For Hazardous application. |
PID instruments are housed in flameproof enclosures for hazardous applications.PID2020F series of instruments finds application in Chemical, Petrochemical, Pharmaceutical, Fertilizer and oil plants.
The PID2020F is widely used in hazardous area of class IIA, IIB and IIC as per IS2148/1981. The enclosures are light weight made of LM-6 with toughened glass.
The enclosures and light weight made of LM-6 with toughened glass. Motorised control valve.
| Model No. | Sensor | Range | Calibration accuracy |
Resolution ºC / ºF |
| nippon 1010F | Pt-100 |
-100.0 to 199.9 ºC -148.0 to 199.9 ºF |
0.25% | 0.1 |
| nippon 1010F | Pt-100 |
-100.0 to 600.0 ºC -148.0 to 1112 ºF |
0.25% | 1 |
| nippon 1010F | Iron / Constantan (J) |
-100.0 to 600.0 ºC -150.0 to 1112.0 ºF |
1% | 1 |
| nippon 1010F | Chrome / Alumel (K) |
-80.0 to 1200.0 ºC -112.0 to 1999.0 ºF |
0.7% | 1 |
| Specifications: | ||||||||||||||||||||||||||||||||||||
|
Isolated transmitters 1000/1500 VRMS isolation 12-36 VDC power supply True 2-wire transmitter Ground loop elimination DIN RAIL Mounting : 75H x 46W x 110D, mm.
| Input | Pt-100 (2,3wire) R.T.D. |
| RANGE | -200 to +800 Zero/ span User adjusttable with trimmer potentiometer |
| Output | 4-20mA dc |
| Accuracy | Better than ±1 % |
| Ambient Conditions | -20 °C to +80 °C |
| R.T.D. break Protection | provided, current goes to 34mA if A is open, current goes to 3.6 mAif B or B1 is open |
| Maximum Load | Maximum loop resistance RL = [ (V+) - 9V ] ÷20mA V+= Loop Power Supply |
| Reverse Polarity | Protection Provided |
| Surge Protection | Provided with zener clamp |
| Housing | 1 ) Head Mounting : DIA (d) - 50 mm, HEIGHT(h) - 27mm 2) DIN RAIL Mounting : 75H x 22W x 92D in mm |
| Application |
|
| NOTES |
|
nippon ISOXR Series is high performance Signal Isolators. The signal Isolators provides excellent isolation between Input & output Signals. This provides noise free isolated signal to the system with accurate conversion fact nippon ISOXR Isolators are housed in ABS molded din rail enclosures. Once again the indigenous R &D offers cost effective solution Application:
To determine the amount of liquid present in the tank, the Ultrasonic transmitter is used. This generates a 4 to 20mA output signal, which is given to instrument. The display indicates the height of the liquid in the tank. By using the volume formula, the volume of the liquid is also displayed. The retransmission output related to volume is given out for SCADA software package for further processing.