My ExportersIndia

For Buyer

For Seller

For Help

Our Product / Services

  1. Computer Monitor 16 Products available
  2. Electronic Components 4 Products available
  3. Measuring Instruments & Equipment 3 Products available
  4. Software Development Service 3 Services available
  5. Security, Metal & Leak Detectors 2 Products available
  6. PVC, PP & Plastic Products 2 Products available
  7. Aluminium,Tin & Metal Containers 2 Products available
  8. Clocks 2 Products available
  9. Surveillance Systems 2 Products available
  10. Window 1 Products available
  11. Business And Corporate Gifts 1 Products available
  12. Bricks 1 Products available
  13. Inverters, UPS & Converters 1 Products available
  14. Spectrometers 1 Products available
  15. Laptops, Computers & Mainframes 1 Products available
  16. Others Products / Services 50 Products / Services available

Products / Services

Leading Manufacturer, Supplier & Retailer of RADIATION COUNTING SYSTEM, Sliding Bench Type, SEMI-AUTOMATIC TLD Badge Reader, FULLY-AUTOMATIC TLD Badge Reader and PORTABLE IDENTIFIER.

GM DETECTOR

  • Window Areal Density - mg/cm sq : 1.5 - 2.0 Eff. Diameter - Inches : 1.15 Material : Mica
  • Wall Thickness - Inches : 0.06 Eff. Length - Inches : 1.45 Eff. Diameter - Inches : 1.125 Material : 446
This G.M. Detector offerred, is enclosed in a PVC cylindrical shell with MHV socket with a suitable HV cable it gets connected to the counting system.This detector is widely used for Beta sample counting application along with either G.M.Counting system GC602A or Radiation counting System RC605A manufactured by Nucleonix systems. This detector is of Centronic LND or it's equivalent make.
View Complete Details

Pan Cake

This is a Pan Cake Detector sensitive to Beta radiation and with window closed can be used for gamma doserate measurements also. Has large surface window area of 16 sq.cm.
View Complete Details

BETA-GAMMA Detector Probe

  • Efficiency Better than 5% with Beta Source (with Sr-90; Yt-90).
This probe is offered as a part of Beta-Gamma Radiation Survey Meter type RM703E. This uses a thin walled GM tube which is housed in a cylindrical shell made of Stainless steel. Detector probe has cable gland arrangement with cable length being 1.0 meters. There is a rotating shutter arrangement made of SS shell, which is kept open for Beta measurement.
View Complete Details

DETECTOR PROBE

  • Detector GM tube type GM125 with 1" end window thickness 1.5 - 2 mg/cm2. End cap is to be removed for Beta Contamination measurement and is retained for Gamma radiation measurement.
  • Detector Probe Dimensions 10cm L x 4cm Dia
  • Detector Cable 1 meter
This is used as a detector probe for Beta-Gamma contamination monitors manufactured by NUCLEONIX SYSTEMS. It is used in both bench model Contamination Monitor CM712 and Portable Model Digital Contamination Monitor CM710E.
View Complete Details

BETA-GAMMA CONTAMINATION PROBE

  • Probe efficiency Better than 5% with Beta source (Sr-90) kept on the surface of the probe.
  • Detector Thin wall Beta-Gamma detector.
  • Detector Probe 35cm L x 3.2cm Dia.

This also serves as a clothing probe, for Beta-Gamma hand, foot and clothing monitor or as a Contamination probe for bench model Contamination Monitor. This uses a thin walled GM tube which is housed in a cylindrical shell made of SS. Detector probe has a cable gland arrangement with cable length being 1.0 meters. There is a rotating shutter arrangement made of SS shell, which is kept open for Beta measurement.

View Complete Details

SCINTILLATION DETECTOR

  • Features 1"x1" NaI Integral assembly, Resolution for Cs-137 better than 8.5%, Operating Voltage 700V to 900V. Etc.
NUCLEONIX Scintillation Detector (1x1 - Flat Type) SD151 is designed to be used with Gamma Ray Spectrometer (Integral) Type GR612 or modular system Type GR611M or its equivalent unit.The integral assembly consists of NaI (Tl) crystal size 1x1, integrally coupled to a 1 12 inch bialkali phototube with mu-metal magnetic light shield. The crystal and the photomultiplier tube are housed in an aluminium container.The assembly is connected to a solid state Pre-amplifier PA311 of NUCLEONIX make. Connectors are provided on Pre-amplifier for EHT, low voltage and signal output. The complete Scintillation Detector can be housed in a Lead Shield. The pre-amplifier is designed to suit a wide range of standard Scintillation detectors.
View Complete Details

ALPHA CONTAMINATION PROBE

  • Alpha Scintillator Screen A circular Scintillator ZnS screen covered with loose aluminized mylar foil of 125mm dia will be used, with a conical light guide for 2" PMT. 2" PMT of Hamamatsu or ETL or Equivalent.
  • Viewing area 100 sq.cm Approx (circular)
  • Operating Voltage Range 800V to 900V
Alpha Contamination Probe type ACP-1 of Nucleonix make serves as a large area (Approx. 100 sq.cm) alpha contamination probe. It is designed to work with Nucleonix make Contamination Monitor (Bench Model) CM712 or its equivalent.
View Complete Details

BETA PROBE

  • Application This is an essential integral part of the Beta Doserate Meter, manufactured & supplied by Nucleonix
  • Beta dose rate CPS /CPM
  • Operating Voltage Range 750V -900V
Beta Probe assembly Type BSP-1, is a plastic scintillator based assembly consisting of 25mm dia x 2mm thick plastic scintillator optically coupled to 30mm PMT. It has a thin aluminized foil as Beta entrance window. It is designed primarily to serve as a Beta probe when connected to Beta Dose rate Meter.
View Complete Details

BETA SCINTILLATION PROBE

  • Operating Voltage Range 900–1000V
  • Backgroud (typical) with 40 mm lead shielding ≤ 20 cpm
Beta probe assembly type BSP-2 is a plastic scintillator based assembly consisting of 2 Dia scintillator coupled to 2 PMT. It has a thin aluminized foil as Beta entrance window. It is primarily designed to serve as a Beta Probe when connected to a Radiation Counting System, type RC605A. It is mounted on a stand which has arrangement for sample tray with shielding option. Additionally slots are provided at different heights for positioning the sample tray.
View Complete Details

GAMMA SCINTILLATION PROBE

  • Operating Voltage Range 900–1000V
  • Backgroud (typical) with 40 mm lead shielding 900 cpm
  • Efficiency ≥ 8% for Cs-137 at 1 cm
This essentially consists of a 2 x 2 NaI Integral detector, with PMT HV bleeder wired & enclosed in a cylindrical shell with appropriate connector brought out for applying HV bias to PMT & also for taking signal output to the Radiation Counting System. This probe with NaI crystal facing downwards is placed in a sample holder having slotted arrangement for placing sample tray. Samples either filter paper deposited air activity sample or in a SS planchet can be kept for gross gamma activity counting. This Radiation counting system cannot be used for selection of a specific energy band. For applications requiring counting for a specific energy band one has to opt for Gamma ray spectrometer.
View Complete Details

LEAD SHEILDING

  • Availability Approx. 113 Kgs.
  • External 200mm dia x 450mm height (approx)
  • Internal 120mm dia x 400mm height
The Lead Castle Type : LS 242 is designed to shield the Gamma scintillation probe GSP-1 from background radiation. The shield is of 40 mm thickness and is built up of SEVEN interlocking rings. The top and bottom are covered by similar interlocking discs. A door is fitted in the bottom ring with 150 degree opening to facilitate easy access to the sample holding tray of gamma scintillation probe. The door is fitted with heavy duty hinges and the inner side of the lead shield is lined with thin aluminium sheet to minimize scattering.
View Complete Details

SCINTILLATION DETECTOR FOR LEAD

  • External 200mm dia x 433mm height, Internal, 120mm dia x 360mm height, Weight, Approx. 92 Kgs
This Lead Shield is designed to shield Scintillation Detectors of NUCLEONIX make. LS 250 is built-up of SEVEN interlocking rings, excluding top & bottom discs. The bottom ring is provided with a small opening so that the cables from the Scintillation Detector Pre-amplifier base could be taken out for connecting to the Gamma ray spectrometer counting system.This Lead Shield Type: LS 250 is compact and just enough to accommodate any of the Scintillation Detectors supplied by NUCLEONIX. The top disc is provided with handle to lift is away for introducing the source on the flat crystal top and liquid vial into the well type crystal respectively. The building block type of construction of lead shield makes it convienient to assemble. The inner side of the lead shield is lined with Aluminium to minimise scattering.
View Complete Details

SOURCE KIT

  • Source type Nominal activity.
  • Cs-137 (gamma) 1.0 - 3.0 microCurve.
  • Tl-204/Sr - 90; 0.10 - 0.30 microCurve.
SK 210 offered by NUCLEONIX contains one each of uncalibrated Beta and Gamma reference sources. These are low activity disc sources of the order of 0.1 to 3 micro curie for Beta and Gamma. Gamma source disc is evaporated and sealed on 25mm dia X 5mm thick plastic disc. Where as Beta source disc is evaporated and sealed on 25mm X 10mm thick plastic disc and covered with 10mg sq.cm aluminized Mylar window These radioactive sources offered are from BRIT & are uncalibrated reference sources with an approx accuracy of 10% in activity. This SK 210 is an ideal choice along with G.M. counting system for educational institutions for teaching lab experiments. Source kit containing the disc sources is offered in an acrylic box of dimensions 86mm X 46mm X 25mm (approx).
View Complete Details

STANDARD INSTRUMENTATION BIN

  • Purity Sturdy and elegant mechanical construction, Designed to house standard modules with amphenol connectors, Can accommodate 12 single width modules or combination of multiple width modules. Etc.
Nucleonix Modular Instrumentation Bin IB401 had been designed to provide mechanical and electrical facilities to accommodate various nuclear instrument modules. Upto 12 single width modules or combination of multiple width modules can be accommodated. The module guiding channels made up of plated steel rods facilitate easy sliding-in and positioning of modules at the same time, adding strength to the bin. The power ON-OFF switch, indicating lamp & monitoring points are all mounted on a thin vertical control panel conveniently located on right extreme of the bin. Also the power supply is conservatively rated to power any combination of modules that the bin will physically accommodate. IB401 modular system Bin provides mounting space for twelve standard module width of the 8 inches high type. The twelve corresponding module connectors are provided with necessary wiring for distribution of the all the standard power supply voltages. A small control panel not occupying any of the available module space is located at the right side of the bin, providing control switches, test points and indicator lamps for power supply.
View Complete Details

Detector Bias Unit

  • Purity (0-1000V) @ 1mA, continuously adjustable High Voltage output, Indication on 3 1/2 LED DPM, Ripple & noise less than 20mV, Regulation better than 0.05% of full scale Etc.
  • OUTPUT INDICATION Provided on a 3 1/2 digit LED, DPM.
  • TEMPERATURE STABILITY Better than 100 PPM.
Nucleonix offers a standard detector bias unit type hv500 which is a compact standardnim module (two bit). This is designed to meet the full hv bias requirement for a broad range of nuclear radiation detectors like g.m.detectors, ionization chambers, scintillation detectors, photo multiplier tubes, etc, . Apart from this range of applications it also can be used as a high voltage source in areas where high degree of regulation, stability and accuracy are required. Output can be varied by a precision ten turn helipot and output indication is provided on a dpm.
View Complete Details

High Voltage Unit

  • Speciality (0-1500V) @ 1mA, continuously adjustable High Voltage output Indication on 3 1/2 LED DPM Ripple & noise less than 20mV. Regulation better than 0.05% of full scale Two bit module
  • OUTPUT VOLTAGE 0V to 1500V continuously variable by a ten turn helipot provided on front panel. (All specifications
NUCLEONIX offers a standard High Voltage Unit Type HV501 which is a compact STANDARDNIM Module (2 bit). This is designed to meet the full HV bias requirement for a broad range of Nuclear radiation detectors like G.M.detectors, ionization chambers, scintillation detectors, photo multiplier tubes, etc, . Apart from this range of applications it also can be used as a high voltage source in areas where high degree of regulation, stability and accuracy are required. Output can be varied by a precision ten turn helipot and output indication is provided on a DPM.
View Complete Details

SINGLE CHANNEL ANALYSER

  • Purity Accepts both positive unipolar or bipolar pulses as input, Modes : INTEGRAL, NORMAL & WINDOW modes of operation Etc.
  • Dimensions Standard single width module
  • Output 4V positive pulse of 0.5 micro sec width
  • Input Positive unipolar or bipolar (0-10V) linear range.
Single Channel Analyser Type : SC530 manufactured by NUCLEONIX is designed primarily to be a constituent unit of Modular Gamma Ray Spectrometer Type : GR611M. Single Channel Analyser SC530 is essentially used for pulse height analysis. It has THREE modes of operations namely INTEGRAL, NORMAL & WINDOW. In Gamma Ray Spectrometer the scintillation detector pulse output is proportional to the Gamma Energy and hence accurate measurement of pulse height by Single Channel Analyser will give the energy information.
View Complete Details

Geiger Counting System

  • Features Ideal choice for teaching labs in physics stream. 20 x 2 LCD dotmatrix display for counts, elapsed time and HV Single board design approach Counts capacity 999999, preset time 9999 sec Variable HV (0-1500V), 1mA Store and Recall facility for data counts
Geiger Counting System Ttype GC601A manufactured by NUCLEONIX is an Advanced Technology based, economy model, designed around eight bit microcontroller chip. This system with accessiories is an ideal choice for teaching demonstrating various G.M. Experiments, as part of Experimental Physics lab to U.G., P.G.Science, U.G. Engineering Physics students. Other streams such as Radiation Physics, Radiochemistry, Radiation Biology and Agricultural Sciences can also use this system. This counting system can be used for carryingout a number of Nuclear Physics experiments such as Characteristics curve of a G.M. Counter, to verify the inverse square law for Gamma Radiation, Absorption of Beta Radiations, efficiency of G.M.Counter for Beta Radiation, determination of the back scattering factor of a material for beta rays etc, .
View Complete Details

RADIATION COUNTING SYSTEM

Radiation Counting system, type RC605A manufactured by NUCLEONIX is a versatile state of art integral counting system designed around eight bit microcontroller chip for using with a variety of detector probes such as Alpha Beta Gamma scintillator detector probe or End window G.M detector probe. RC605A is Highly recommended for gross alpha activity contamination measurement (in water & other environmental samples) with alpha probe AP165 connected, for Radio analytical labs, Health physic counting labs and Environmental survey labs at Nuclear power stations. Radiation Counting System essentially has a processor card and other electronic circuits to generate continuously variable HV upto 1500V to be applied to scintillation detector Probes ( , , ) or End window G.M.Tube, amplify the detector output and convert them to digital pulses for counting and displaying the recorded counts for a preset time. Microcontroller design facilitates programmability for background, standard and sample counting. The data can be downloaded into PC or printed directly onto a printer. System facilitates counting of samples either on planchets or filter paper.
View Complete Details

Counting System

  • Detector material Zns (Ag) Screen covered with Aluminized mylar foil.
  • Density 10mg/cm 2
  • Efficiency 25%
Alpha Probe type AP165 manufactured by NUCLEONIX is meant to be used along with Radiation Counting System model RC 605A for counting alpha samples. Radiation Counting System along with Alpha Probe essentially works as an Alpha Counting System.Alpha Probe of NUCLEONIX make is essentially an integration of ZnS (Ag) scintillator screen, optically coupled to a 2 PMT & covered by a pin hole free aluminized mylar foil to provide, sealing against ambient light. Scintillations received by PMT because of Alpha particles will be converted to electrical charge and inturn to voltage pulses. Each of these events after amplification in the RCS will be counted. The required high voltage is applied (which is typically 900V) through RCS to the Alpha Probe.Probe has a drawer assembly which facilitates sample placement on sample tray for counting applications. The counting samples are usually deposited on planchets of 25mm diameter or filter paper upto 38mm diameter.
View Complete Details

GAMMA SAMPLE

  • Purity Manufactured confirming to ANSI N 42.17, Complies to IS -9000 part III & V, for climatic tests. Etc.
Radiation Counting system, type RC605A manufactured by NUCLEONIX is a versatile state of art integral counting system designed around eight bit microcontroller chip for using with a variety of detector probes such as Alpha Beta Gamma scintillator detector probe or End window G.M detector probe. This system is suitable for counting Gamma samples with gamma scintillation appropriate detector probe.Radiation Counting System essentially has a processor card and other electronic circuits to generate continuously variable HV upto 1500V to be applied to scintillation detector Probes (alpha, beta, gamma) or End window G.M.Tube, amplify the detector output and convert them to digital pulses for counting and displaying the recorded counts for a preset time.Microcontroller design facilitates programmability for background, standard and sample counting. The data can be downloaded into PC or printed directly onto a printer.System facilitates counting of samples either on planchets or filter paper.This system will find applications for counting of air activity, wipe, environmental, geological and other samples for both beta , gamma and alpha activity. Activity report is generated for unit volume of sample.
View Complete Details

LOW BACKGROUND BETA

  • Applications This system is highly recommended for the estimation of gross Beta activity in Environmental samples, including air, water (river, lake, pond, ground & sea waters), soil, vegetation & biological sample.
  • Purity Adequate Lead shielding has been provided to minimize background, Modular in construction. Etc
Low Background Beta counting system LB615 is primarily designed for the measurement of gross Beta activity contamination in water and other environmental samples . It is highly recommended for Radio analytical Labs and environmental survey labs at Nuclear power stations for this application. Counting of samples having very low specific beta activity becomes difficult with conventional G.M. Counters having high background and low efficiency. A thin plastic scintillation detector based beta counting system has twin advantage of low background and high efficiency when compared. This system uses thin plastic scintillation detector based main counter and another wide area plastic scintillator based guard counter. System works on the principle of anticoincidence. The detector assembly is provided with a 3 lead shield to reduce background.
View Complete Details

Sliding Bench Type

Sliding bench SB205 is designed specially for the purpose of mounting bench the G.M counter accessories for doing the experiments in a most convenient fashion. This essentially consists of a bench with sliding groves with a graduated S.S scale fixed on one side of it. Scale has graduations both in cm & inches upto 50cm20 inches. There are three vertical sliding mounts, one for mounting of End Wndow G.M detector, Second is Absorber Holder & Third is Source Holder & source mounts. Each of these mounts can be positioned along the slide scale to have required distance between the end window to the source with absorber mount interposed in between. End window detector is housed in PVC enclosure with MHV socket fixed on to it.
View Complete Details

PORTABLE IDENTIFIER

Portable Isotope Identifier PI 1002 is primarily designed to detect and identify multiple nuclides. It provides quantified results using field strength analysis and stores the results and spectrum for future reference. The instrument can be operated in the Identifier, MCA, and Dosimeter modes of operation for data acquisition. This instrument performs all the tasks needed in the field survey for the detection & quantification of radioisotopes. Choice of built -in detector option with (1 12 " X 1 12 ") NaI crystal or external detector option with (2 " X 2 ") or(3" X 3")NaI crystal.Meets IEEE N42.34 performance Criteria for the detection and identification of Radio nuclides.Operational modes: Identifier mode, MCA mode, Transfer stored spectrum mode, administration mode, dosimeter mode.Zoom in, Zoom out functions facilitate the user to focus on the region of interest.Powered by Internal 2X 5200 mAh Li-ion batteries, facilitates 15 hrs continuous operation.Built in 1k MCA, uses 18 bit SAR ADC, speed 400kSPS, Data length 32bit.Built in alarms facility :both visual and aural indication.Doserate measurement in the range of 1Rh to 1Rh or equivalent Svh.Data storage :internal memory to store & upto 30 spectra.
View Complete Details

SEMI-AUTOMATIC TLD Badge Reader

Semi Auto TLD Badge Reader TL1010S is a personal monitoring system, designed to read the TLD card (TL dosimeters) worn by radiation workers. This Badge Reader system is designed using state of art electronics, improvised electro-mechanical system, embedded code and software to load and read the TLD cards for TL glow curve dose. System facilitates entry of ID number for the person and his dose record and glow curve can be stored in the system. TL dosimeter is heated by hot gas (N 2 ) jet to 280 o C using a SS heater assembly & TL output is recorded using PMT where integral of the current output is proportional to the dose. It is a Thermoluminescent dosimeter based personnel monitoring system. Thermoluminescent dosimeters make use of the property of certain materials which absorb energy when exposed to X, Gamma or Beta radiation. On heating, the absorbed energy is released in the form of visible light. A plot of light intensity emitted against temperature is known as a glow curve. For a given heating rate, the temperature at which the maximum light emission occurs, is called the glow-peak temperature and it is characteristic, of the individual TL material (also called phosphor). The quantity of the visible light emitted (TL output) is found to be proportional to the energy absorbed by the TL material. The TLD personnel monitoring system essentially consists of two major parts: TLD badge and the TLD badge reader. The TLD Badge Reader comprises of a plastic cassette containing three Teflon TLD discs (13.3mm and 0.8mm thick) that are mechanically clipped on to circular holes (12.0mm) punched in an aluminium card (52 x 30 x 1mm). The TLD Badge Reader is designed to measure X, Gamma and Beta radiation dose. The metal filter combination (1mm Al + 0.9mm Cu) is provided to reduce the photon energy dependence of the TL discs. The TL badge reader is calibrated such that the TL output of the disc under the metallic filter reads directly the gamma radiation dose. .
View Complete Details

FULLY-AUTOMATIC TLD Badge Reader

Fully Auto TLD Badge Reader TL1010F is a personal monitoring system, designed to read the TLD card (TL dosimeters) worn by radiation workers. This Badge Reader system is designed using state of art electronics, improvised electro-mechanical system, embedded code and software to load and read the TLD cards for TL glow curve dose. System facilitates entry of ID number for the person and his dose record and glow curve can be stored in the system. TL dosimeter is heated by hot gas (N 2 ) jet to 280 o C using a SS heater assembly & TL output is recorded using PMT where integral of the current output is proportional to the dose. It is a Thermoluminescent dosimeter based personnel monitoring system. Thermoluminescent dosimeters make use of the property of certain materials which absorb energy when exposed to X, Gamma or Beta radiation. On heating, the absorbed energy is released in the form of visible light. A plot of light intensity emitted against temperature is known as a glow curve. For a given heating rate, the temperature at which the maximum light emission occurs, is called the glow-peak temperature and it is characteristic, of the individual TL material (also called phosphor). The quantity of the visible light emitted (TL output) is found to be proportional to the energy absorbed by the TL material. The TLD personnel monitoring system essentially consists of two major parts: TLD badge and the TLD badge reader.
View Complete Details

TLD BADGE READER

  • SPECIFICATIONS Heater Element:Kanthal / SS circular, ~ 12mm dia.Temperature Profile : Non-linear reproducible., Light Detection : R6095 or equivalent. Etc.
TLD READER SYSTEM Type TL109-D developed and manufactured by NUCLEONIX systems is a personal dosimeter reader system designed to read the dose recorded by the wearer of the TL Dosimeter along with personnel ID punched code on the badge automatically during readout cycle. The TL dosimeter which records the integrated dose received is to be worn by the personnel who are to be monitored for their radiation exposure, which can be estimated on the basis of the TL Dosimeter readings. TLD dosimeter works on the property of certain materials which absorb energy when exposed to X, a or rays. On heating, the absorbed energy is released in the form of visible light which is proportional to the absorbed energy. TLD Badge: It comprises of a plastic badge and thick aluminium card on which three circular holes are punched and teflon embedded TL discs (CaSo4 : Dy) are chipped into the corresponding holes. A symmetric V cut provided in the card permit the card to be loaded in the plastic badge only in one way and ensure proper positioning of the badge in the magazine. The TLD card is provided with three rows of punched holes for the purpose of badge identification. The holes punched in a specified sequence to provide unique ID to each of the personnel. This ID is read out by the TLD Reader at the time of measurement.
View Complete Details

STACK GAS MONITORING

Stack Gas Monitor, Type: SM809 manufactured by Nucleonix Systems, designed using state-of-art electronics is primarily used for monitoring Alpha, Beta activity present in the form of suspended particulate in air and Kr-85 preset in the form of gas. It is very much essential to monitor the quality of air in & around Radiochemical plants, reprocessing plants and other similar facilitates. Usually stack, by pass lines are let into this system & after measurements, it is connected back to stack. It essentially has an air suction system comprising of a suction pump, rotometers to measure air flow rate, beta suction chamber with arrangement for trapping of suspended dust particulate onto the filter paper. An end window GM tube of 1 dia facing the filter paper counts for Beta activity in CPM CPSBq on continuous basis. In addition this system has Alpha air-sampler detector assembly consists of a filter holder 60mm dia, a suction chamber with air inlet and outlet & detector housing fabricated with stainless steel .Alpha Detector consists of ZnS (Ag) deposited on loose mylar support of 50mm dia coupled to matched PMT with Pre-amplifier. Detector Efficiency achieved is of the order of 25% for Plutonium alpha particles over the entire window area.
View Complete Details

Multi Channel Analyzer

  • Feature Compact, 1K /8K MCA with USB interface. Built-in High voltage (0-1200V) @ 0.5 amps with adjustable bias voltage to detector. Etc.
  • Specifications MCA resolution: 256, 512, 1K/8K.Spectrum memory: 128K bytes single port SRAM. • Max counts / channe
Multi-Channel Analyzer (MCA) is an important part of nuclear spectroscopy system. The major requirement of MCA is for nuclear Pulse Height Analysis(PHA) in energy spectroscopy. The USB-MCA presented here, incorporates state of art technologies like FPGA, USB bus interface and precision analog electronics to meet the stringent system requirements in nuclear pulse spectroscopy. The resolution supported by the USB-MCA ranges from 256 channels to 1K8K channels selectable via software, making it suitable for all spectroscopy applications of low resolution (e.g. NaI-PMT). The USB bus interface of the MCA provides an excellent connectivity with most of the new PCs and lap-top computers meeting minimum requirements of PC. The ANUSPECT application software provided with the USB-MCA, seamlessly integrates with the hardware, featuring a range of standard functions required for analysis and acquisition.
View Complete Details

THERMOLUMINESCENCE READER

  • Purity Built-in USB port facilitates connection to PC, Built-in USB port facilitates connection to PC, Heating rates are 10°c / sec to 40°c / sec. Etc.
Thermo luminescence Reader Type TL1009 designed and offered by NUCLEONIX SYSTEMS is a versatile controller based unit, facilitating the user to subject the TL sample under study to the desired heating profile, to record the digitized TL glow curve. This unit stores both integral value and digitized glow curve into EEPROM memory. This unit records the data in 200 channels, temp, TL intensity & Run time values. Entire electronics including PMT, HV bias, Temperature controller circuit, Heater transformer heater strip, sample drawer assembly, data acquisition electronics is all integrated into a single enclosure. The user interface to the unit is through a powerful software GUI, coded in .net which runs on Windows platform. This system essentially works as a PC controlled TLD reader with command buttons and dropdown menus defined for various functions.
View Complete Details

RADIOACTIVE CONTAMINATION ANALYSER

  • Purity System is useful in measuring RaC in metal samples, Highly recommended for medium / large scale recycle steel industry having smelting furnaces., 1K/4K/8K channel resolution. Etc.
Radioactive contamination Analyzer (RaC) RA1006 is a laboratory instrument. It is highly recommended for Radio analytical labs. Additionally, it is also highly recommended for steel & foundry industry for their QA departments to measure RaC in their components products. System measure RaC in Bqg. Most of the portable hand held meters cannot measure contamination in Bqg. Also hand held meters may fail to detect very low levels of contamination less than 0.1 Bqg, unless carefully measured & interpreted. Whereas RaC measurement by this system is a fool proof method. This is a most sensitive equipment designed to record Gamma Spectra of the sample under study. This consists of a 3 X 3 NaI scintillation detector with Pre-Amplifier, High Voltage, Linear Amplifier Multi-Channel Analyzer System. Detector is covered by 5060 mm lead shielding to reduce background. This system can detect nuclide specific contamination in any steel alloy casting sample & quantify it also, in BqKg or Bqgm etc. Sample of Approximately 2kg in the form of small pellets in a cup of 3 dia. X 3 height can be placed on the detector for the measurement. System gives nuclide peak & area under the peak will quantify the contents in Bqgm.
View Complete Details

END WINDOW G.M. DETECTOR

  • Gas Filing Ne+Hal.
  • PVC enclosure tube dimensions Outer dia 25 mm. Length : 76 mm.
  • Gamma Sensitivity 18 CPS / mR/hr (Co60).
  • Starting Voltage max 325V ± 25V.
  • Plateau threshold voltage max 400V.
  • Plateau length 150V.
  • Operating Characteristics Recommended Operating voltage :500V ± 50V. Plateau slope : ≤6%.

This is an End window G.M detector of 1cm in dia used for Beta-gamma counting application. It is recommended for college and university teaching lab experiments, in physics / Engineering physics / Nuclear & Radiological physics etc.,

This detector is of Centronic / LND or it's equivalent make. It is enclosed in a PVC tube & fitted with MHV socket for applying HV bias.

Window

Thickness - 1.5 - 2.0 : mg/cm2Useful diameter - 9 : 0.36.Material : Mica.

Cathode

Thickness - 250 : mg/cm2Sensitive Length - 39 : mm.Material : Chrome Iron.
View Complete Details

WIDE END WINDOW G.M. DETECTOR

This G.M. Detector offerred, is enclosed in a PVC cylindrical shell with MHV socket with a suitable HV cable it gets connected to the counting system.This detector is widely used for Beta sample counting application along with either G.M.Counting system GC602A or Radiation counting System RC605A manufactured by Nucleonix systems. This detector is of Centronic / LND or it's equivalent make.
Window
Areal Density - mg/cm sq : 1.5 - 2.0Eff. Diameter - Inches : 1.15Material : Mica
Wall
Thickness - Inches : 0.06Eff. Length - Inches : 1.45Eff. Diameter - Inches : 1.125Material : 446 SS
Tube Dimensions
Material Diameter - Inches :1.32 Max. Overall Length - Inches : 2.1Gas Filing : Ne+Hal
Gamma Sensitivity
50 CPS / mR/hr ( Co60 )
Operating Characteristics
Max. Starting Voltage : 375Recommended Operating voltage : 500Operating voltage range (in volts) : 450-750V