Our Products
We are leaders in the market for providing best range of TWV : Vanstone Thermowell, TWT : Sanitory Thermowell, TWS : Screwed Thermowell, NV4 : Block and NV3 : Needle Valve
Thermowells within the TWV series are machined from solid bar and mounted between mating flanges for process insertion. This design of thermowell will accept thermocouples (TC), resistance temperature detectors (RTD), as well as mechanical and digital thermometers.
| The dimensions of the Vanstone flange corresponds to the mating raised face diameter of the process flange.The Vanstone flange surface finish is usually machined with a phonographic spiral serration to match the mating process flange. During installation a gasket is inserted between the process flange and the Vanstone flange to maintain a pressure seal. A top flange is then placed over the Vanstone thermowell and bolted to the process flange using the correct bolting torque forces for the bolt size and material. | ||||||
| The required lap flange is not standard and can be provided as an optional extra. Special Features :
|
TWT thermowells are manufactured from solid bar stock. They are installed into the process using a clamp connection. The smooth, polished surface of the wetted parts guarantee easy cleaning and prevents potential contamination of the process.This design of thermowell will accept thermocouples (TC), resistance temperature detectors (RTD), as well as mechanical and digital thermometers.
Special Features :| Food and beverage industry | |
| Biochemical and pharmaceutical industry | |
| Sterile process technology |
Thermowells are used as accessories with temperature instruments and temperature sensors to protect its basic sensing element from corrosive and mechanical damages due to process parameters.
Special Features :| Fabricated From Bar Stock | |
| Standard For Manufacturing Followed- Ptc 19.3 | |
| Thermowell Available In Exotic Materials Such As Hastalloy-C, Tantalum, Monel, Titanium, Inconel 600 etc | |
| Thermowells Are Used As An Accessory With Temperature Instruments, Sensors, To Protect Its Basic Sensing Element From Corrosive And Mechanical Damages Due To Process Parameters |
NV4 type gauge is a block and bleed needle pattern gauge valve with specially designed integral bleed.Ideal for use on application requiring bleeding or venting of media.Self centering needle non-rotating, on the valve seat.The conical metal tip (stem type CT) press fitted ensures perfect alignment for positive bubble tight shut-off.Standard connection are male inlet and female outlet or female inlet and female outlet from 1/4 to 3/4.
Applications :| Installation of instrument and gauge | |
| Isolation of Instrument | |
| Venting of Instrument. | |
| Liquid and vapor service |
Type miniature compact design needle valves are ideal for bubble tight shut-off in applications where space is at a premium. The mini series are available with metal to metal low torque seating (Stem Type YS). Available with end connections in sizes 1/8 to 1/4 and as pipe connections
Applications :| Instrument air lines | |
| Control panels | |
| Air header assemblies | |
| Gas sampling | |
| Laboratory equipment | |
| Instrument isolation | |
| Control loops | |
| Gas and liquid service |
D130 luminosity data logger Small and exquisite, portable. Automatic measurement mode, does the sensory part of luminosity of this instrument accord with the mere accommodation curve of International Commission on Illumination . USB Interface transmit data and power supply, begin the recording mode manually and automatically .
Special Features :| Alarm setup and indication | |
| Recording and low battery indication | |
| Manual and automatic start mode | |
| USB port for data traffic and power supply | |
| Status indication via Red/Yellow LED and Green LED | |
| Analysis software windows 98/2000/XP/Vista/7 |
| Memory | 32000 readings |
| Measuring rate | 2sec.to 24h |
| Measurement Range | 0.4 to 30.0m/s |
| Measurement Resolution | 0.1 m/s |
| Accuracy | ±3.5% or ± 0.2 m/s |
| Warm up period | Less than 2 seconds |
All types of process parameters like Boilers, Dairy equipment, Sugar, Chemical, Pharmaceutical, Breweries, Paper & Pulp, Food industries, Agriculture, Metrological, Water treatment, HVAC, Heat treatment & all Sprocess industries.
| Screen | l.c.d. 9” Tft |
| Resolution | 640 X 480 |
| Colour | 256 Colour |
| Display | Size 120 X 160 Mm |
| Front | Key Operated |
| Power | supply 24 Vdc / 1amp Smps Power Supply. |
| Rs-232 :or Rs 485 | Communication Port OPTIONAL |
| Hi-Low | Alarm By Colour Change |
| Optional | 15” Colour L.C.D.Monitor Resolution 800 X 600 |
| Cutout | 180 (h) X 260 ( W ) |
Field Adjustable Compact and Reliable Snap Action Microswitch with Piston
| Sensor | : AISI 316L SS Piston | |
| Wetted Parts | : AISI 316LSS | |
| Enclosure | : SS304, Weatherproof to IP 65 | |
| Ambient temperature | : - 40°C to + 80°C | |
| Process temperature | : -40 to 120°C | |
| Operating pressure | : 75% of the Scale Value | |
| Process Media | : Air, Oil and Water |
|
The DP930 Differential Pressure Switch is a low-cost easy to use switch for very low pressure applications. The switch can monitor positive, negative, or differential pressure and with an easy to adjust set point knob makes field set up and adjustment hassle free. The differential pressure switch includes a SPDT relay rated for 1A @ 250V and can be set as low as 0.08 w.c. (20 Pa)
Special Features :| High Quality, Low-Cost | |
| Visual Set Point Indication | |
| Hassle-Free Field Adjustment Knob | |
| 2% Repeatability |
| Media | : Air and compatible gases | |
| Max Pressure | : 40” w.c. (10KPa) | |
| Temperature Limits | : 5 to 140° F (-15 to 60° C) | |
| Electrical Rating | : 2A @ 250 V | |
| Electrical Connectio | : Screw terminals | |
| Process Connection | : 3/16” I.D. flexible tubing | |
| Enclosure Rating | : NEMA 13 (IP 54) | |
| Weight | : 3.5 oz (100 g) | |
| Accessories | : 6 ft (1.8m) flexible tubing (2) Static pressure fittings Z type mounting bracket Mounting screws |
|
| Repeatability | : 2% | |
| Deadband | : approximately 10% of max set point |
Food & beverage, pharmaceutical, cryogenics, chemical & petrochemical industries, conventional & nuclear power Plants, pumps, hydro-cleaning machines, presses, engine Compressors, turbines, diesel engines & refrigerating plants.
Special Features :| Field Adjustable | |
| Compact and Reliable | |
| Snap Action Microswitch |
| Sensor | : Phosphor Bronze Bellows | |
| Wetted Parts | : Copper Alloy | |
| Enclosure | : PVC; Weatherproof to IP 32 | |
| Ambient temperature | : - 20 °C to + 70 °C | |
| Process temperature | : Max 100 °C | |
| Operating pressure | : 75% of the Scale Value | |
| Process Media | : Air, Oil and Water |
|
Food & beverage, pharmaceutical, cryogenics, chemical & petrochemical industries, conventional & nuclear power Plants, pumps, hydro-cleaning machines, presses, engine Compressors, turbines, diesel engines & refrigerating plants.
Special Features :| Field Adjustable | |
| Compact and Reliable | |
| Snap Action Microswitch |
| Sensor | : Phosphor Bronze Bellows | |
| Wetted Parts | : Copper Alloy | |
| Enclosure | : PVC; Weatherproof to IP 32 | |
| Ambient temperature | : - 20 °C to + 70 °C | |
| Process temperature | : Max 100 °C | |
| Operating pressure | : 75% of the Scale Value | |
| Process Media | : Air, Oil and Water |
|
||||||||||||||||||||||||
Food & beverage, pharmaceutical, cryogenics, chemical & petrochemical industries, conventional & nuclear power Plants, pumps, hydro-cleaning machines, presses, engine Compressors, turbines, diesel engines & refrigerating plants.
Special Features :| Field Adjustable | |
| Compact and Reliable | |
| Snap Action Microswitch |
| Sensor | : Phosphor Bronze Bellows | |
| Wetted Parts | : Copper Alloy | |
| Enclosure | : PVC; Weatherproof to IP 32 | |
| Ambient temperature | : - 20 °C to + 70 °C | |
| Process temperature | : Max 100 °C | |
| Operating pressure | : 75% of the Scale Value | |
| Process Media | : Air, Oil and Water |
|
||||||||||||||||||||||||