Post Buy Requirement
OL
Chennai, Tamil Nadu, India
Add Review

Our Products #785138

Padmounted Switchgear

  • Features Robust design, Optimum performance, Longer service life
View Complete Details

Dry Type Distribution Transformer

  • Features Maximum rated through Current available in two ranges of 65 A and 100A, Suitable for Transformers up to 2000 KVA, Eliminates use of Oil, Low maintenance required, Suitable for Delta/Star applications
  • Application Applicable for Dry type Distribution transformers, It can be used near the load center
  • 11 kV 65 A & 100 A
  • Coarse –fine/Reversing Bi-directional
  • 17 250 V

Rated Insulation level Highest voltage for equipment kV Rated separate source AC withstand voltage kV(r.m.s) Rated lightning impulse withstand voltage kV(peak)
(a)Tapchanger to ground 12 28 75
(b)Between phases 28 75
(c)Over tapping range 8 25
(d)Between adjacent contacts 8 25
(e)Between contacts of pre selector 8 25
Weight of tap changer 380 kg
View Complete Details

Wall Mounting RTCC Panel

  • Features Sturdy in nature, Perfect finish, High performance, Digital Tap Position Indicator, Electronic Automatic Voltage Regulating Relay, Control Selector Switch Auto / Push Button, Anti Condensation Heater
View Complete Details

Tap Changer

  • Application Used in power transformers up to 38 Y /50 MVA Delta applications, Suitable for transmission lines where power rating is less than 220 kV, Used for Industrial applications
  • Features It can be used for Linear, Coarse –fine/reversible operations, High speed resistance transition flag switching cycle used, Transition time is approximately 75 milli seconds, Long life of contacts

Technical Specification

Rated voltage 33 kv 66 kv 110 kv
Highest system voltage 37 kv 72 kv 123 kv
Rated Insulation Level
i) Rated separate source AC withstand voltage
a) Tap-changer to ground 70 140 230
b) Between phases 70 140 230
c) Over tapping range 50 50 50
d) Between adjacent contacts 50 50 50
e) Between contacts of Change-over selector 50 140 140
ii) Rated lightning impulse withstand voltage kV(peak)
a) Tap-changer to ground 170 350 350
b) Between phases 170 350 350
c) Over tapping range 150 150 150
d) Between adjacent contacts 150 150 150
e) Between contacts of Change-over selector 200 350 350
Maximum rated through-current 200 A
Direction of power flow Bi-directional
Tapping arrangement Coarse-fine,Reversing
Maximum number of tap positions 23
Switching capacity 330 kVA
Rated step voltage 1650 V
Oil displacement( In liters) 285 355 383
Oil quantity (In liters) 270 325 350
Weight of tap changer with oil 606 Kg 655 kg 677 kg
View Complete Details

Indoor VCB Panel

  • Features Reciprocating Bar operates all 3 phase drives, Visible Snatch Gap to determine Contact erosion, Silent Spring Charging Operation, Insulated Single/Double bus arrangement
View Complete Details

Capacitor Switch

  • Features Fast acting solenoid mechanism which eliminates pre-strike and re-strike of contacts, Mechanical contact position indicator easily visible from side or bottom of the switch
View Complete Details

Load Break Switch

  • Features Since Arc quenching medium is air, no need to provide additional insulation. Hence it is most Economical, It is more reliable since no need for additional cooling medium
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Jayaseelan (On Load Gears)
  • No: 433, Sidco Estate , Ambattur, -98, Chennai, Tamil Nadu, India
  • Share us via
Browse Our Products list of On Load Gears Chennai, Tamil Nadu
Post Buy Requirement
OL
Chennai, Tamil Nadu, India
Add Review

Our Products #785138

Padmounted Switchgear

  • Features Robust design, Optimum performance, Longer service life
View Complete Details

Dry Type Distribution Transformer

  • Features Maximum rated through Current available in two ranges of 65 A and 100A, Suitable for Transformers up to 2000 KVA, Eliminates use of Oil, Low maintenance required, Suitable for Delta/Star applications
  • Application Applicable for Dry type Distribution transformers, It can be used near the load center
  • 11 kV 65 A & 100 A
  • Coarse –fine/Reversing Bi-directional
  • 17 250 V

Rated Insulation level Highest voltage for equipment kV Rated separate source AC withstand voltage kV(r.m.s) Rated lightning impulse withstand voltage kV(peak)
(a)Tapchanger to ground 12 28 75
(b)Between phases 28 75
(c)Over tapping range 8 25
(d)Between adjacent contacts 8 25
(e)Between contacts of pre selector 8 25
Weight of tap changer 380 kg
View Complete Details

Wall Mounting RTCC Panel

  • Features Sturdy in nature, Perfect finish, High performance, Digital Tap Position Indicator, Electronic Automatic Voltage Regulating Relay, Control Selector Switch Auto / Push Button, Anti Condensation Heater
View Complete Details

Tap Changer

  • Application Used in power transformers up to 38 Y /50 MVA Delta applications, Suitable for transmission lines where power rating is less than 220 kV, Used for Industrial applications
  • Features It can be used for Linear, Coarse –fine/reversible operations, High speed resistance transition flag switching cycle used, Transition time is approximately 75 milli seconds, Long life of contacts

Technical Specification

Rated voltage 33 kv 66 kv 110 kv
Highest system voltage 37 kv 72 kv 123 kv
Rated Insulation Level
i) Rated separate source AC withstand voltage
a) Tap-changer to ground 70 140 230
b) Between phases 70 140 230
c) Over tapping range 50 50 50
d) Between adjacent contacts 50 50 50
e) Between contacts of Change-over selector 50 140 140
ii) Rated lightning impulse withstand voltage kV(peak)
a) Tap-changer to ground 170 350 350
b) Between phases 170 350 350
c) Over tapping range 150 150 150
d) Between adjacent contacts 150 150 150
e) Between contacts of Change-over selector 200 350 350
Maximum rated through-current 200 A
Direction of power flow Bi-directional
Tapping arrangement Coarse-fine,Reversing
Maximum number of tap positions 23
Switching capacity 330 kVA
Rated step voltage 1650 V
Oil displacement( In liters) 285 355 383
Oil quantity (In liters) 270 325 350
Weight of tap changer with oil 606 Kg 655 kg 677 kg
View Complete Details

Indoor VCB Panel

  • Features Reciprocating Bar operates all 3 phase drives, Visible Snatch Gap to determine Contact erosion, Silent Spring Charging Operation, Insulated Single/Double bus arrangement
View Complete Details

Capacitor Switch

  • Features Fast acting solenoid mechanism which eliminates pre-strike and re-strike of contacts, Mechanical contact position indicator easily visible from side or bottom of the switch
View Complete Details

Load Break Switch

  • Features Since Arc quenching medium is air, no need to provide additional insulation. Hence it is most Economical, It is more reliable since no need for additional cooling medium
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Jayaseelan (On Load Gears)
  • No: 433, Sidco Estate , Ambattur, -98, Chennai, Tamil Nadu, India
  • Share us via