Post Buy Requirement
Paramount Industries
Ambala, Haryana, India
Verified Add Review

Our Products #710078

3 Phase VAF Meter Relay

The company is known as a major Manufacturer & Supplier of 3 Phase VAF Meter Relay, with the partner featured protection relay safeguarding the damages to any gadget. The 3 Phase VAF Meter Relay has an integrated load restoration function using external available sources from site that allows the re-establishment of the power system after recovery of the system frequency. The flexible protection functions are another highlight of the 3 Phase VAF Meter Relay.

Details

  • Rate-of-frequency, rate of-voltage or rate of current change function can be created as per the site requirement
  • Provides circuit-breaker control
  • Additional primary switching devices (grounding switches, transfer switches and isolating switches) used in LT & HT Switchgear
  • Can be controlled from the relay
View Complete Details

Electrical Automation System

We are one of the dependable Manufacturers and Suppliers of Electrical Automation System from Ambala, Haryana. Our Electrical Automation System is mainly used in Extra High Tension (EHT) applications viz., mrs, Sub Station & Power House etc.

Features

  • Useful for multiple EHT Inputs or Standby Transformer but single HT Output for distrbution load with help of EHT/HT Distribution Transformer
  • Device has automatic detector for EHT voltage and current & temp also
  • Load can automatically be shifted from one source to other before approaching to saturation
  • Electronic interlocking kit safe guard for any fiddle or any type of fault
  • Unit converts manual trolley of existing VCB, SF6 breaker to fully Automation Charge / Discharge & thus without manpower HT / EHT Switching
View Complete Details

Neutral Failure Protection Relay

The automatic protection is an important requirement in LT, and our Neutral Failure Protection Relay can precisely provide the same. As a Manufacturer and Supplier of Neutral Failure Protection Relays, the company offers a device that can provide instant tripping to the existing panel if the floating neutral is generated. The Neutral Failure Protection Relay effectively safeguards the users as well as all the electronic & electrical gadgets within quick time.

Features :

  • Electronic visual
  • Audio indication
  • Useful for multiple LT outputs from the same source of panel

 

Details

  • Automatic Protection Required in Lt 
  • Application Useful for Multiple Lt Outputs from the Same Source of  Panel
  • If Floating Neutral Generates Then Device Has Automatic Instant Tripping to Existing Panel
  • It Safe Gaurds Any Type of Electronic & Electrical Gadgets with in Fraction of Seconds
  • Electronic Visual & Audio Indication
View Complete Details

Instantaneous-Trip Circuit Breakers

We are known as a highly distinguished Manufacturer & Supplier of Instantaneous-Trip Circuit Breakers, with the instrument capable of picking up commands irrespective of existing current transformer ratio. The Instantaneous-Trip Circuit Breakers can convert CT of 800/5 To 15/5 or vice-versa. The electronic latch circuit comes with tripping indication of light emitting diodes of each shape of fault and there are provisions of reset facilities in Instantaneous-Trip Circuit Breakers. The Instantaneous-Trip Circuit Breakers do not hold LT/HT and OCB/VCB until fault is removed and the complete protection of LT/HT and OCB/VCB and connected distribution transformer unit is ensured.

Range

  • Integrated Operational Amplifier Over Current Circuit (1 Milliamp) : Sensitivity relay set unit consisting of auxiliary CT, with primary current of 5 Ampere and secondary current of 0.5 Ampere (Potential Voltage of 110 Volts)
  • Integrated Operation Amplifier Earth Fault (0.05 Milliamp) : Sensitivity relay set unit consisting of auxiliary CT, with primary current of 1 Ampere and secondary current of 0.1 Ampere (Potential Voltage of 110 Volts)

Graph


Download Detail File : Click Here
View Complete Details

Automatic Power Factor Controller

Varying in stages from stage two to twelve, the Automatic Power Factor Controller (accurate) can work with the transformers and capacitors. As a Manufacturer and Supplier of Automatic Power Factor Controller, we offer a 2% accuracy rate which can be converted from manual to automatic. This can avoid the transformer burning caused by the rising current and leading power factor. The Automatic Power Factor Controllers come with heavy duty capacitors and contactors and there is a three-year replacement at site guarantee.

Features :

  • Electronic automatic reactance discharge kit to avoid accidents
  • Single phase and unbalance cut off protection
  • Electronic overload protection to avoid burning of TFR & capacitor
  • Auto-cum-manual switching provision with visual indication
  • Suitable for indoor & outdoor transformers
  • Saves manpower and improves efficiency of TFR & equipments
  • Withstands harmonics overload and suitable for linear and non-linear load   
  • Over current up to 4 in max Current
  • Low losses less than 0.2 kw/kvar
  • Temperature Range : 25-70oC
  • Long operational life more than 2 lac hours   
  • Reduces power consumption hence energy
View Complete Details

Automatic Star Delta Starter

The Automatic Star Delta Starter is an open enclosure type device that can be suited for the induction motors with electronic overloads. Having an integrated operational amplifier for over current and protection from short circuits, the Automatic Star Delta Starter is built on electronic latch circuits with tripping indication. We are a well-known Manufacturer and Supplier of Partner Automatic Star Delta Starter, which has provisions for the facility reset. In cases of the starting motor winding (U1V1W1) and ending motor winding (U2V2W2) being disconnected or incorrect, the Automatic Star Delta Starter will not take any commands. The Automatic Star Delta Starters have sensors with special directional current that can enhance its service life.

Features :

  • 1 amp sensitivity relay unit including single phase protection both on input & output side
  • Three phase low voltage cutoff 350 volts
  • Three phase high voltage cut off 450 volts
  • Unbalanced voltage tripping 400 (+/-) 10% volts with 1 to 3 second tripping electronic timer
  • Electronic overload built with integrated operational amplifier for over current circuit as per HP for each motor with 1 amp sensitivity relay set unit

 

PARTNER fully automatic open enclosure type suitable for induction motor with Electronic overload built with integrated operational amplifier for over current & short circuit protection. With 1 Amp sensitivity relay unit including Single phase protection both on input & output side, and Three phase low voltage cutoff 350 volts, Three phase high voltage cut 0ff 450 volts ,   Unbalanced voltage tripping 400 (+/-) 10% volts with 1 to 3 Second tripping electronic timer, including  of Electronic overload built with integrated operational amplifier for over current circuit as per HP for each motor with 1 amp sensitivity relay set unit Electronic latch circuit with tripping indication for each tripping and provisions of reset facilities also features not to hold starter until parameters does not improve. MOST IMPORTANT PARTNER STARTER DOES NOT TAKES COMMAND  in any respect  if  (U1V1W1), ( U2V2W2)  are incorrect we mean to say beginning & end of winding of motor are not properly connected with its special  directional current  sensors which increases life of Motors

Graph


Download Detail File : Click Here
View Complete Details

Automatic Energy Saver Electric Switch

Intelligent street light controller specially designed for energy Saving in conventional street light systems. By using this controller you can save up to 33% energy by staggering the unwanted lights by midnight (Considering 50 % staggering time). Day light power saving scheme can also save some more energy.
Apart from energy saving this can also save manpower, operating cost and can reduce manual operating errors. This controller is programmed on longitude & latitude base for the whole year for sunrise and sunset timings.
Sunrise and sunset time changes On day to day basis and in one month there is a time change of about 30 minutes. For entire year sunrise and sunset time changes by about 190 minutes.
With these much change of time a conventional timer will not serve the purpose. It can save energy up to 8 % against conventional manual operation, Photo sensors or conventional timers. Our controller incorporates a real time clock with in built battery backup for minimum 8 years. There is no need to reprogram the controller even if supply fails for long duration

SpecificationsAdvance Microcontroller based design and real-time clock base systems. Real time clock with inbuilt battery with life of more then 8 years Data protection of user parameter by specially RAM which hold the parameters for more then 10 years with out any power Street light ON / OFF on Longitude, Latitude base sunset and sunrise time generation. Controller operates 365 days on real-time based clock with auto calculate sunrise and sunset times as per geographic location. In built auto recovery systems for power failure which helps in streetlight operation. Month wise civil twilight timings (Day light power saving) which helps precise ON / OFF time in all weathers (Advantage of Sunlight before sunrise and Sunlight after sunset). Password Protection. ( As the systems installed at remote location and in open conditions any body can fingered which create problem for street lighting operation) Scrolling display of events which helps to monitoring the systems. Very easy key board operation. Auto / Manual facility by way of relay operation for faster service mode. User settable On Delay up to 99 minutes between R Y & Y B Settable Individual lines Staggering facility to switch OFF and switch ON lights by late night can save energy when there is no traffics. (Can switch off one phase at 10 P.M. and another phase at 1A.M.) Three mode of staggering system 1) Rotation mode in this one phase will off at predetermine time and phase will selected on date basis to equal burning of all lamp. i.e to day R phase off tomorrow y phase OFF and day After tomorrow B phase will be OFF ( 33 % energy saving ) 2) Alternate phase system in which to day R phase off tomorrow Y and B Phase OFF . For equal burning of lamp. ( 50 % energy saving ) 3) Any phase can be switch off at any time and any time can be ON ( Energy saving in range of 33 to 100 % ) Eight Date range programming facility to disable staggering mode for festival and special occasion. Manual stagger off facility for special requirement. Power redundancy for controller even 1 phase 170 VAC controller can work.

Technical Specifications

  • Supply : 3 Phase 230 VAC/ph + / - 25 %, R Y B N
  • 4 Wire supply Systems. 50 Hz (+ / - 10 %)
  • Power Consumption : 2 W (Stand by) 5 W (on full load)
  • Controller : 8 Bit micro controller
  • Programming function : Switching on Longitude & Latitude base
  • Real Time Clock : Inbuilt battery, with battery life of more then 8 years
  • Parameter data protection : With special device which hold the data for more then 10 years without any power and Password protected.
  • Display : 16 character and two lines LCD display with backlight.
  • Contacts : 3 Potential free contacts for normal and staggering
  • Redundancy : Operates up to single phase 170 V Ac
  • By pass : Provision to by pass by way of Auto / manual switch
  • Operating Temperature : 2 to 55' centigrade and humidity 90 % non-condensing


Advantages

  • No frequent time to be change according to season.
  • Redundant Power supply to controller. Any phase up to 150 Volt controller will work and contactor will be operated up to 170 VAC
  • Real-Time Clock with very high life of more then 5 years. No Battery.
View Complete Details

Automatic Sewage Sump Controller

The Automatic Sewage Sump Controller has a vacuum impregnated single phase transformer of the step-down buck boost type. As a Manufacturer and Supplier of Automatic Sewage Sump Controller, we offer the transformer unit with primary voltage of 230 volts and secondary voltage of (0-16v) & (0-18v) with current cap of 2amp. The Automatic Sewage Sump Controller withstands wide voltage fluctuations of 150 volt to 300 volts with ease.

Features :

  • Light emitting diodes for motor on/off indication
  • Stainless steel probes corrosion resistant supported with Bakelite spacer & insulator inside the sump well
  • Electronic control card having integrated operational amplifier to start motor automatically when sump well is full & to stop the motor if water in sump well falls down as per site requirements
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us