2 Products availableWe can supply you this indicator on pressure as well as on load
Digital Indicator for Compression Testing machine with ten point calibration facility.
Type :- Panel Mounted
Size :- 92x196 mm
Display :- 6 digit 7 segment LED Display,
Input :- 4-20 mA or Any Strain Gauge based Sensor
Set point :- Two relay output.
Function:- Peak hold facility and 6 key for parameter setting.
Calibration :- Easy calibration process with 10 points (Calibration) facility.
Password Protection :- Double password protection.
Start & stop facility from controller as well panel also through NC
Supply - 220 V AC, 2500 Watts, 50 Hz, 10%
Additional Information:
Delivery Time : 1-2 days
PRC offers a very unique & innovative Key Code Reader to facilitate the automobile key lock manufacturers. It is very much required to know the Key code since every key has a different code. For reproduction purpose it is required to reveal the code of a particular key, a system is required which can display the code.
PRC key code reader is a perfect solution for this application. It is a digital device which can detect the code of a particular key precisely. This is an ideal device to improve the rate of production.
PRC Key code reader is equipped with a Touch pad for the key which detects code after entering the key no. A digital display of 16 digits provided to enter the key no. and to display the code. A unique four digit key no. is allotted to all keys and their codes respectively. As soon as user enters a four digit key no., Indicator displays the code of that particular key. This code is sent for further processing of key lock. Optionally a Bar code scanner is also provided if the keys are with Bar code nos.
Salient features:
Standard specification:
Data acquisition is the process of measuring an electrical or physical phenomenon such as load, pressure, torque, voltage, current, temperature, pressure, or sound with a computer. A Data acquisition system consists of sensors, measurement hardware, and a computer with programmable software. Compared to traditional measurement systems, PC-based Data acquisition systems exploit the processing power, productivity, display, and connectivity capabilities of industry-standard computers providing a more powerful, flexible, and cost-effective measurement solution.A Data Acquisition System is comprised of three parts; an I/O sub-system, a host computer and the controlling software. However, some systems, such as the Power DNA Cube running a standalone Linux application combine the I/O sub-system and the host CPU in the same package. These systems are often referred to as embedded DAQ systems.
PRC is one of the leading manufacturers and suppliers of wide range of Load Indicators to suit the diversified requirements from all segments. PRC Manufactures its all products using optimum grade raw material that is sourced from our trustworthy vendors, this is developed in accordance with set industry standards. The offered indicators are enormously valued for its diverse features like durability, safe to handle, compact designs, low power consumption and longer service life.
Salient features;
PRC offers following option for users:
Digital Load Indicator With Load Cell: Cap 5-50 Tons
Option-3: Microcontroller Based, 6 Digits Display, Two Set Points With Potential Free Relay O/P Tare Zero, With 5 Meter Wire, With Jumbo 4” Led Display
To validate the the design safety factors, pile design & lengths,
Pile Load Testing is an important factor for the piling works that should be properly
planned and factored into the project schedule and project costs at an early stage. It
provides the quick and accurate monitoring of force and displacement during te test.
This test is performed to confirm the design load calculations and to provide guidelines
for setting up the limits of acceptance for routine tests. It also gives an idea of the
suitability of the piling system. Initial Test on piles are to be carried out at one or more
locations depending on the number of piles required. Load applied for the initial (cyclic)
load test is 2.5 times the safe carrying capacity of the pile. Geo Technical Engineering
provides pile load testing for any project by applying static and dynamic test methods as