Were risers are a form of internal hydrant for the fireman to use and are always pressurized with water. Wet risers are only required for buildings where the topmost floor is higher than 30.5 meters above the fire appliance access level.
Wet riser system comprises duty fire pump with standby pump discharging into a 150mm diameter riser pipe with landing valves at each floor and to which canvas hose with nozzles cab be connected to direct the water jet at the fire. A jockey pump is usually provided to maintain system pressure. For high rise buildings, each stage of the wet riser should not exceed 70.15 meters.
Down comers are also a form of internal hydrant for the firemen to use and are always charged with water tank located at the top of a building but without any pumps. Down comers are only permitted for private residential buildings with open balcony approach where the topmost floor is not higher than 60 meters above the fire appliance access level and should be adopted for low cost flats only.
Down comers system comprises a high level water storage tank discharging into 150mm diameter riser pipe with landing valves at each floor and to which canvas hose with nozzles can be connected to direct the water jet at the fire. No pumps are provided and therefore the system pressure is limited to the static pressure only
Fire detection and alarm systemsare designed to provide warning of the outbreak of fire and allow appropriate fire fighting action to be taken before the situation gets out of control. As all systems are designed primarily to protect life, property, this places a great responsibility on the designer because each building will present a different set of problems in relation to the risk of fire and fire spread.Each fire detection and alarm system therefore must be specially designed to meet the requirements for each building.
The fire alarm system can either be operated automatically or manually. Automatic operation is via the detectors whereas manual operation is by breaking the glass at the manual call point (break glass unit).To override the automatic operation of this system in case of its failure during a fire, use the nearest unit of the manual break glass.
Audio Visual Strobes / Alarmsare lights combine a single- or quad-flash strobe light with an 87dB piezo alarm. Each unit comes with 3 bolts and rubber spacers for mounting. Wiring is separate for light and alarm. |
IONISATION SMOKE DETECTOR Conventional type ionization smoke detector with mounting base. |
OPTICAL SMOKE DETECTOR Conventional type optical smoke detector with mounting base. |
HEAT DETECTOR Conventional type heat detectors 60 Deg. C with mounting base. |
Sprinkler Standard Response, Standard Coverage BSPT, Chrome Finish K-Factor 5.6. Temperature Rating 57, 68, 79 Deg. C.Mounting Pendent, Upright, Sidewall & Concealed * Available in Chrome Finish* For concealed sprinkler cover plate is with white finishor chrome finish. |
DRY ALARM VALVE- is a key component of a Dry Water sprinkler System. The pipe is usually filled with compressed air and Nitrogen. Operating temperature is below 0C or higher than 7C. |
Medium Velocity Water Spray Nozzles has an external deflector, which discharges water in a directional cone shaped pattern of small droplet size. The water is uniformly distributed over the surface to be protected. The nozzle is used in deluge water spray system for special hazard fire protection application. As the design and intent of specific water spray system may vary considerably, a MV nozzle is made available in several combination of orifice sizes and spray angles. The minimum desirable pressure to achieve a reasonable spray pattern is 1.4 Kg./Sq.cm. The water distribution pattern as shown in the graph in following pages is at an average pressure of 2.0 Kg/Sq.cm. The change in pressure between 1.4 to 3.5 Kg./sq.cm. does not affect considerable change in spray angle. The spray pattern shown is with indoor application. System designer must consider wind velocity while designing the system for outdoor application. Field obstruction if any affecting the spray pattern of the nozzle must also be considered. The nozzle may be oriented to any position which is deemed necessary to cover the hazard.Some of the areas where this system is widely used are: | |||
| |||
Horizontal storage vessels (like LPG Bullets, NH3 storage tanks etc.) | |
Vertical storage vessels (like benzene, xylene, toluene tank age etc.) | |
Spherical storage vessels (like LPG bullets, spheres etc.) | |
Spot protection (Protection of selective areas/equipments) |
Maintenance
Use Teflon tape or soft thread sealant onmalethread of the nozzle. The nozzles must be hand tightened into the fitting. LIFECO make wrench must be used to tighten the nozzle unit into the fitting. Excessive tightening torque may result into serious damage to nozzle arms and the deflector which may affect spray pattern of the nozzle andit'sperformance.
Co2 at atmospheric pressure is a colorless, odorless and electrically Non Conductive inert gas, It has high expansion ratio which facilities rapid discharge and allows three dimensional quick penetration in the entire hazard area. Made from premium quality components, this system's importance lies in the fact that it has high efficiency to extinguish fire by reducing the oxygen content of the protected area below the point where it can support combustion. Designed to withstand every climatic conditions, these devices are widely used in following area of applications:
Transformers, Power Generators, Machinery Spaces, Ships Holds, Electrical Equipments, Chemical Equipments, Chemical Work & Stores, Switch Rooms, Electric Movers, Solvent Stores, Dip Tanks and Oil Cellars etc.
Description/Specification of Co2 Flooding System
We are engaged in offering a comprehensive range of qualitative Co2 flooding systems. These have high expansion ratio that leads to rapid discharge and facilitates three dimensional penetration of the entire hazard area in a fastest manner. Some of the advantages of Co2 system are:
Fast in action | |
Non damaging nature towards the equipment | |
Non conducting |
Dry Chemical Powder Modular Type Automatic Fire Extinguisher 5 Kg Capacity- Powder Coated MS Body, Fitted With Heat Sensitive Glass Bulb Sprinkler, Pressure Gauge, Filled With BC Or ABC Powder Complete With All Accessories.
Dry Chemical Powder Modular Type Automatic Fire Extinguisher 10 Kg Capacity- Powder Coated MS Body, Fitted With Heat Sensitive Glass Bulb Sprinkler, Pressure Gauge, Filled With BC Or ABC Powder Complete With All Accessories.
FIRETRACEis a simple self-activating system designed for installation inside enclosed cabins and machinery housing to detect and extinguish fire automatically, at its early stage. It is ideal for any application where the risk is located within an enclosed or confined space. |
| ||||||||||||
Short Branch Pipe Gun Metal 63mmwith Detachable Hexagonal Nozzle as per IS:903 with ISI Mark (Also available in Stainless Steel or Aluminium or Copper) | ||
|
Delivery Hose coupling male & femaleGun Metal 2.5"(63mm), inst. type 63mm X 63mm size as per IS: 903 with ISI mark. (Also available in Stainless Steel or Aluminium or Copper) | ||
|
Suction CouplingGunmetal 4 Male & Female Round Threaded as per IS:902. (Available in 3 also) | |
Also available in standard quality |
Suction StrainerGunmetal 4 having Female Round Thread as per IS:907 (Also available in 3) | |
Also available in standard quality |
Single Hose Box- Wall mounting type in 600mm X 400mm X 250mm) size to accommodate 1 lengths of 7.5 mtr. or 15 mtr. or 30 mtr. hoses and a branch pipe with glass covered single door with lock and key arrangements. | ||
|
Double Hose Box- Wall mounting type in 750mm X 600mm X 250mm size to accommodate 2 lengths of 7.5 mtr. or 15 mtr. hoses and a branch pipe with glass covered double door with lock and key arrangements
|
Hose Reel Drum, swinging wall mounting type made of mild steel sheet to accommodate 30mtr or 36.5mr of 19mm dia Rubber Hose with nozzle along with suitable bracket for fixing on the wall.
|
Rubber Hose for Hose Reel Drum Made of natural / synthetic rubber with plain or corrugated finish as per IS:444 with ISI Mark (Type 1: WP-6 Kgf/cm, Type 2: WP-10 Kgf/cm)
|
|
Foam Making Branch Pipe FB5X Made from Aluminium Alloy with 63mm G.M. Male Inst. Inlet with Pickup tube 225 LPM |
Portable Inline Inductors Made from Aluminium Alloy with 63MM G.M. Male Inst. Inlet in one hand and Female Inst. Outlet in other hand with Pick-up tube. |
Medium Expansion Foam Branches To produce stable, superior quality medium expansion foam with 63mm G.M. male inst. Inlet.(Made of SS 304 or Aluminium Barrel) |
Model | Range Mtrs (at 3.5 bars inlet pressure) | Nominal Expansion | Lenghtmm | WeightKgs |
MX 225 | 06 | 1:40 | 530 | 5.0 |
MX 450 | 08 | 1:40 | 615 | 6.2 |
High Expansion Foam Generators To Generate large amount of HX Foam with 63mm G.M. inlet.(Made of SS 304 or Aluminium body/shell) |
Model | Output M3/min (at inlet pressure) | Nominal Expansion | Approx Height mm | Approx WeightKgs |
HX | 47 (at 3.5 bars) | 1:270 | 610 | 17.0 |
Mini Super | 60 (at 5.5 bars) | 1:310 | |
Aqueous Film Forming Foam Synthetic based foam compound mixed with addition of fluorodensides processing the property to create the film of water solutions that floats on top of non-polar flammable liquids as per IS:4989 PART-2 with ISI Mark (Available in: 3% or 6% Foam Compound in 20 ltrs HDPE Can) |
Collecting Breech(GM) having 1 no. 63mm Female Inst. Inlet and 2 nos. 63mm Male Inst. outlet. As per IS:905 |
Controlled Dividing Breech(G.M) with Control Valve having 1 no. 63mm Male Inst. Inlet & 2 nos. 63mm Female Inst. Outlet with control. |
Double Male Adaptor(G.M) Inst. of 63mm as per IS |
Double Female Adaptor(G.M) Inst. of 63mm as per IS |
2 way Fire Brigade InletCast Iron (C.I.) having 2 nos. of 63mm Male Inst. NRV Inlet with flange. |
Non Return Valve- Gunmetal with 63mm male inst. |
ROSETTE PLATE Single leaf rosette plate either in chrome plate or White finish (Also available in Stainless Steel) |
we are specialized in providing fire safety systems to ensure protection of your building, properties & critical equipment and most importantly of your priceless life. You cant deny the fact that accidents never happen with prior appointments. They can take place anytime and anywhere be it residential complex, commercial building or your office. A global statistics of such accidents, shows that worldwide fire breakouts every seven seconds, which results in more than 15, 000 deaths per year.
Fire and smoke spread to other parts or floors of the buildings only through construction gaps. Although active fire protection systems like sprinklers and fire extinguishers quench the fire to some extent, they are not adequate to stop the spread of fire and smoke from one zone to other. We also help architects & engineers in designing fire and smoke safe buildings, complying with NBC regulations and also to obtain credit ratings for LEED certified Green Buildings.
We help our customers by designing fire and smoke safe zones within buildings by employing passive fire protection systems. Following the concept of containment and compartmentalization of fire, our company helps clients to stop fire and smoke spread from its place of origin to other parts of the building, thereby enhancing the fire integrity of your buildings. Our fire protection system works in line with a companys business continuity planning/disaster management planning in saving your important information stored in the data warehouse/server rooms and ensuring safe storage of business information.