Post Buy Requirement
Precision Storage Vessels Pvt Ltd
Kanyakumari, Tamil Nadu, India
Add Review

Other Products / Services #618674

Electric Hot Water Heater

Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial applications. Electric calorifiers are installed in hospitals, hotels, Sports Centres and General Residential Buildings.
View Complete Details

Compressed Air Receiver

Air receivers are manufactured in quality Carbon steel for storing compressed air with capacities range from 100 litres to 50, 000 litres.

Standards :
Precision design and manufacture Air Receivers in accordance with EEC 9723 for pressure equipment or ASME Pressure Vessel code.
View Complete Details

Electric Water Boiler

  • Advantages Efficiency is maintained throughout the range of load. Even at part load all energy is converted into heat, Installation is simplified. Etc
High Capacity Electric Water Heaters
Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial applications. Electric calorifiers are installed in hospitals, hotels, Sports Centres and General Residential Buildings.

Standards
ASME Code construction:- All tanks are constructed in accordance with ASME code section IV Stamped and labeled for 125 PSI (8.6 BAR) as Standard.
View Complete Details

Indirect Heated Storage Tanks

Indirect Heated Storage calorifiers are one of the easiest method of generating hot water for both domestic and industrial applications. Storage calorifiers are installed in hospitals, hotels, sports centers and general residential buildings. PRECISION Calorifiers can be used in sites where a dedicated plant producing steam for laundry or hot water boiler is available.


Storage Calorifier
Storage calorifers are sized to meet the peak demand period with recovery periods varying from one to four hours.


Advantages



  • Electric power is not required, hence no big investments in Transformer etc.

  • Heating coil duty is high.

  • No frequent shutdown due to short circuit etc.

  • No need of higher inventory electric spares.


.
ASME Code construction:- All tanks are constructed in accordance with ASME code section IV
Stamped and labeled for 125 PSI (8.6 BAR) Standard. Precision also design High Capacity Water Heaters / Calorifiers as per British Standard BS 853:1996 or BS 5500:1997 or in accordance with Art 3.3 of the European Directive EEC/97/23 for pressure equipment. Hot Water Indirect KW Shell Material Configuration Capacity.


Vessel Lining Precision Coat
Precision coat is a polymerized coating which is applied to all internal surfaces of the tank. Tank surfaces are first sandblasted and cleaned to a white metal finish and then precision coat is applied uniformly. The tank is then forced cured at 95C to form a glossy lining unaffected by thermal shock from -6C to 100C. Precision coat is approved by US department of agriculture and with NSF/61 certification for drinking water.


For steam and condensate the battery is a simple 2-pass U-tube battery. Heater batteries are constructed from finned tube. This extended surface reduces the overall size of the battery. Plain tube can be supplied and should be specified at the enquiry or order stage so that provision is made for fitting the larger battery. Plain tube will be recommended when the operating conditions are known to make it advisable.

View Complete Details

Air Separators

  • Standard working pressure 10 bar
  • Standard Working Temperature 177°C

Material of Construction:-



  • Carbon Steel Flanged to Class 150/PN16/ PN25

  • All steel body

  • Stainless steel strainer
    .


Advantages :-



  • Elimination of air from closed circulation system.

  • Tangential style

  • Low velocity vortex

  • Avoid inefficient pump operation.

  • Low pressure drop across the separators.
    .


Benefits :-



  • Recover air perfectly

  • Optimum pump operation

  • Prevent pump cavitation.
    Precision tangential air separators are manufactured in state of the art modern facility with automatic machines.


.
Principle:-

Precision Tangential air separators removes air from the system through centrifugal action, with a combination of centrifugal force and with reduction of velocity. This makes the air, force water towards the outlet connection, where the separated air moves to the low velocity center. Air is removed from the system through air vent.

View Complete Details

Oil / Gas Fired Water Heaters

Direct Oil / Gas Fired water heaters are the best solution where fuel fired hot water system can be used. Wide range output can be achieved in this water heaters. Fully automatic burners are used for safe operation.


Advantages



  • Efficiency is maintained throughout the range of load.Even atpart load all energy is converted into heat.

  • Space requirements are minimum.

  • Separate boiler not required.

  • Installation is simplified.

  • The calorifier can be installed with minimum electric load.

  • Maintenance is kept to a minimum.

  • Low nox burners are used.

  • Fuel efficient burners are used.

  • Diesel oil, Natural Gas, LPG and Propane can be used.

  • Can also be used with solar or heat pump system where oil orgas fired system can be considered as a backup.


Water heaters are fitted with removable type fire tube heat exchanger. These heat exchangers aremade of carbon steel tubes and coated with specially formulated coating material to withstand hightemperature.


Burner
Mono block pressure jet fully automatic oil / gas fired burners are used to heat the water. Depend onrecovery, burners can be selected either on / off type or full modulation type. Burners will be highlyfuel efficient and with low nox capabilities.


Gas Fired Burner



  • Energy Saving and compatible with environmental requirements

  • Quiet in operation and designed for easy maintenance

  • Designed and approvaed in accordance with the EuropeanStandard EN676

  • Plug in contact facilities the installation

  • Hinged flange

  • Designed for one stage, two stage, or modulating operation

  • Available for natural gas, LPG, town gas, biogas
    .


Oil Fired Burner



  • Energy Saving and compatible with environmental requirements

  • Quiet in operation and designed for easy maintenance

  • Reliable and trouble free

  • Designed and approved in accordance with the EuropeanStandard EN267

  • Suitable for high resistance boilers

  • Industry standard components easily available

  • Designed for on / off and high/low operation

  • Plug-in contact facilities the installation

  • With hydraulic air adjustment

  • Fuel Light distllate oil Class D (1.5-5.5 cSt@40C)

View Complete Details

Dirt Separators

Precision Air and Dirt Separator are designed to eliminate air and separate debris associated with any hydronic system. In removable type High Velocity air and dirt separator, a removable flanged type end cover is installed so that easy access for coalescing medium and dirt removal. Non removal type high velocity air and dirt separator are also manufactured. Air and dirt separator are designed and manufactured as per ASME section VIII Div 1 and registered with National Board of Boiler and Pressure Vessel inspectors. Material of construction will be carbon steel. Connections are flanged to Class 150, Class 300, PN16 or PN 25. External surface will be coated with red oxide primer and with one coat red enamel paint. Standard working pressure will be 10 bar. Designs up to 20 bar available on request.


Each air and dirt separator to be fixed with air vent. A tap is fitted on top of the removable cover (in removable type) and in body for non removable type to facilitate system fast fill and removal of floating impurities and air trapped within the air separator.


Application

Precision Air and Dirt Separator removes entrained air bubbles and dirt particles in the system. Small Air bubble coalesce and form larger air bubbles which rise to the top of the vessel and vented through the air vent. Dirt particles that are collected at the bottom of the separator can be removed through the blow down valve .In case of coalescing medium to be cleaned then top removable cover to be removed for access. Precision air & dirt separators provide higher efficiency with reduced pressure drops so a smaller pump can be used to achieve maximum efficiency.


PALL Ring Technology

Precision air and dirt separator use proven PALL ring technology. By using Pall Ring technology micro bubbles as small as 18 microns, and dirt particles of 35 microns can be removed. It removes air from place where air vent cannot be installed and also it removes and separates solid particles. Pall Rings are kept in a stainless steel basket which can be removed from the top flange of removable type air and dirt separator. Pall rings are made of Stainless steel 304 material. Air bubbles are separated by the pall ring through coalescene process where dirt particles are caught and drifted to the bottom of the tank, further removed through blowdown valve.


Typical Specifications

Furnish and install, as shown on plans, a removable / non removable type Air and Dirt separator. The unit shall have flanged inlet and outlet connections to the vessel. A vent connection shall be fitted to the top of the vessel to enable installation of Airvent. Air and Dirt separators shall have all steel body construction designed fabricated and stamped as per ASME Section VIII Div I with a working pressure of 10 bar. Each Air & Dirt Separator to be fitted with a blow off tap to remove the air trapped within the separator. Air and Dirt Separator shall use high surface area pall rings made of stainless steel 304 to separate air and dirt with minimal pressure drop. Removable type Air and Dirt separator shall have removable upper head for removal, inspection and cleaning of the pall ring basket.

View Complete Details

Boiler Feed Tank 2

Boiler Feed Tank

View Complete Details

Boiler Feed Tank

We present a large variety of carbon steel Boiler Feed Water Tanks which are strong in built and high in performance. Our Boiler Feed Tanks are specially fabricated by our technicians to meet the demands of several industries. We are renowned as a Prominent Boiler Feed Tanks Manufacturer in Nagercoil, India. Use of finest grade raw materials makes our Boiler Feed Tanks them a highly reliable product in market. These tanks reduce any kind of inconvenience and are easy to use.
Features
Corrosion freeUser friendly Highly durableRobust construction
Applications
For all kinds of Fire tube boilersIndustrial PurposePressures upto 30 bar
View Complete Details

Air Receivers

Air Receivers are manufactured in quality Carbon steel for storing compressed air with capacities range from 100 litres to 50, 000 litres.

 

Standards : Precision design and manufacture Air Receivers in accordance with EEC/ 97/23 for pressure equipment or ASME Pressure Vessel code.

 

Connection : Connection can be of screwed / flanged.

 

Supports : Supports can be of L type , ring type or Tubular.

 

Working Pressure : Air receivers are manufactured to 10.8 bar working pressure as standard ( Pressure available up to 50 bar)

 

External painting : All compressed air tanks will be painted with RAL 5015 Blue color.

 

Optional Accessories : Safety Valve, Pressure Gauge, Auto Drain valve etc.

Download


Download Detail File : Click Here

Graph


Download Detail File : Click Here
View Complete Details

Oil & Gas Fired Water Heater

Oil & Gas Fired Water Heater are the best solution where fuel fired hot water system can be used. Wide range output can be achieved in this water heaters. Fully automatic burners are used for safe operation.

 

Advantages

  • Efficiency is maintained throughout the range of load.Even at part load all energy is converted into heat.
  • Space requirements are minimum.
  • Separate boiler not required.
  • Installation is simplified.
  • The calorifier can be installed with minimum electric load.
  • Maintenance is kept to a minimum.
  • Low nox burners are used.
  • Fuel efficient burners are used.
  • Diesel oil, Natural Gas, LPG and Propane can be used.
  • Can also be used with solar or heat pump system where oil or gas fired system can be considered as a backup.

 

Water heaters are fitted with removable type fire tube heat exchanger. These heat exchangers are made of carbon steel tubes and coated with specially formulated coating material to withstand high temperature.

 

Burner
Mono block pressure jet fully automatic oil / gas fired burners are used to heat the water. Depend on recovery, burners can be selected either on / off type or full modulation type. Burners will be highlyfuel efficient and with low nox capabilities.

 

Gas Fired Burner

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Designed and approvaed in accordance with the European Standard EN676
  • Plug – in contact facilities the installation
  • Hinged flange
  • Designed for one stage, two stage, or modulating operation
  • Available for natural gas, LPG, town gas, biogas
    .

 

Oil Fired Burner

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble – free
  • Designed and approved in accordance with the European Standard EN267
  • Suitable for high resistance boilers
  • Industry standard components easily available
  • Designed for on / off and high/low operation
  • Plug-in contact facilities the installation
  • With hydraulic air adjustment
  • Fuel – Light distllate oil Class D (1.5-5.5 cSt@40oC)

Download


Download Detail File : Click Here
View Complete Details

High Capacity Electric Water Heaters

High Capacity Electric Water Heaters Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial applications. Electric calorifiers are installed in hospitals, hotels, Sports Centres and General Residential Buildings.

Standards
ASME Code construction:- All tanks are constructed in accordance with ASME code section IV Stamped and labeled for 125 PSI (8.6 BAR) as Standard.

Precision also design electric calorifiers as per British Standard BS 853:1996, BS 5500:1997 or in accordance with Art 3.3 of the European Directive EEC/97/23 for pressure equipment.

Advantages

  • Efficiency is maintained throughout the range of load. Even at part load all energy is converted into heat.
  • Space requirements are minimum. Separate boiler fuel storage tanks are not required.
  • Installation is simplified.
  • The calorifier can be installed directly with the power supply.
  • Maintenance is kept to a minimum.
  • Electric calorifiers are clean.
  • Electric calorifiers are extremely quiet.


Precision Coat
Precision coat is a polymerized coating which is applied to all internal surfaces of the tank. Tank surfaces are first sandblasted and cleaned to a white metal finish and then precision coat is applied uniformly. The tanks are then forced cured at 95oC to form a glossy lining unaffected by thermal shock from -6oC to 80oC. Precision coat is approved by US department of agriculture and with NSF/61 certification for drinking water.

Standard – Shells

  • Steel SA516 Gr-70
  • Coating FDA approved Precision coat material

 

Heating Element ( Howden UK) : Heaters can be designed to operate in 3-phase, 415 volts, 50 HZ / 60 HZ supply. Precision uses two types of commonly used heating elements namely replaceable element and removable core element.

Replaceable Type : The elements on this type of immersion heater can be changed only after draining contents in the water heater.

Removable Core Type : Failed elements can be changed without draining the calorifier or removing the immersion heater from the shell. This saves time in changing the defective elements and with less down time. By this we can save the heated water without draining it.

Materials : Heating elements are available in copper, incoloy or Incoloy 825 which are suitable for any water conditions.

Download


Download Detail File : Click Here
View Complete Details

Air Separator

Material of Construction :

  • Carbon Steel – Flanged to Class 150/PN16/ PN25
  • All steel body
  • Stainless steel strainer
    .

Advantages :

  • Elimination of air from closed circulation system.
  • Tangential style
  • Low velocity vortex
  • Avoid inefficient pump operation.
  • Low pressure drop across the separators.
    .

Benefits :

  • Recover air perfectly
  • Optimum pump operation
  • Prevent pump cavitation.
    “Precision” tangential air separators are manufactured in state of the art modern facility with automatic machines.

.
Principle :

Precision Tangential air separators removes air from the system through centrifugal action, with a combination of centrifugal force and with reduction of velocity. This makes the air, force water towards the outlet connection, where the separated air moves to the low velocity center. Air is removed from the system through air vent.

Operating Conditions :

  • Standard working pressure : 10 bar
  • Standard Working Temperature – 177°C
  • Can supply for pressure up to 30 bar
View Complete Details

Chilled Water Buffer Tanks

Chilled Water Buffer Tanks are designed to operate with a minimum water volume, which typically ranges from 22 litre to 38 litres per ton for air conditioning application, for to get better temperature accuracy.

 

Most of the chiller compressors can only start 3 to 4 times per hour. If the compressor is off and if there is a demand for chilled water the compressor cannot get on immediately. Without chilled water, building will not get the required cooling. To solve this problem chilled water buffer vessels are added in the system. These tanks increase the capacity of the chilled water in the system and stabilize the return.

  • Tank manufactured as per ASME Standard
  • Ring supports
  • Internal Baffle
  • Air vent
  • Insulation and cladding (optional)
  • Material A36 (other materials consult factory)
  • Flanged connection (inlet and outlet)
  • Manhole (optional)
  • Tank will be externally sandblasted to SA 2.5 and then coated with two coats of red oxide primer.
  • Horizontal configuration also available .
  • Manufacturers data report for pressure vessels from U-1A as required by the provisions of ASME code will be furnished for each chilled water buffer tank.
  • Standard working pressure 10 bar, Test pressure 15 bar.
  • Plate Thickness are in excess to relevant codes.

Download


Download Detail File : Click Here
View Complete Details

Boiler Feed Tank 1

Boiler Feed Tank

View Complete Details

Indirectly Heated Storage Tank

Indirect Heated Storage calorifiers are one of the easiest method of generating hot water for both domestic and industrial applications. Storage calorifiers are installed in hospitals, hotels, sports centers and general residential buildings. PRECISION Calorifiers can be used in sites where a dedicated plant producing steam for laundry or hot water boiler is available.

 

Storage Calorifier : Storage calorifers are sized to meet the peak demand period with recovery periods varying from one to four hours.

 

Advantages

  • Electric power is not required, hence no big investments in Transformer etc.
  • Heating coil duty is high.
  • No frequent shutdown due to short circuit etc.
  • No need of higher inventory electric spares.

 

ASME Code construction:- All tanks are constructed in accordance with ASME code section IV

Stamped and labeled for 125 PSI (8.6 BAR) Standard. Precision also design High Capacity Water Heaters / Calorifiers as per British Standard BS 853:1996 or BS 5500:1997 or in accordance with Art 3.3 of the European Directive EEC/97/23 for pressure equipment. Hot Water Indirect KW Shell Material Configuration Capacity.

 

Vessel Lining – Precision Coat

Precision coat is a polymerized coating which is applied to all internal surfaces of the tank. Tank surfaces are first sandblasted and cleaned to a white metal finish and then precision coat is applied uniformly. The tank is then forced cured at 95ºC to form a glossy lining unaffected by thermal shock from -6ºC to 100ºC. Precision coat is approved by US department of agriculture and with NSF/61 certification for drinking water.

 

For steam and condensate the battery is a simple 2-pass U-tube battery. Heater batteries are constructed from finned tube. This extended surface reduces the overall size of the battery. Plain tube can be supplied and should be specified at the enquiry or order stage so that provision is made for fitting the larger battery. Plain tube will be recommended when the operating conditions are known to make it advisable.

Download


Download Detail File : Click Here
View Complete Details

Expansion Tanks

Expansion Tanks are used in a closed loop heating or chilled water HVSC system to absorb the expanding water and to control the pressure in the system.

Expansion tanks are fitted with a replaceable type heavy duty butyl bladder which absorbs the expanded water thus avoiding direct water contact with the metal tank.

  • Designed and manufactured as per ASME Section VIII DIV I
  • Replaceable bladder design
  • Vertical configuration with ring support
  • Easy to install
  • Factory Recharge Pressure : 0.83 bar
  • Maximum Operating Temperature 115oC
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Manuel Selva Ezhil (Precision Storage Vessels Pvt Ltd)
  • Kalpadi P.O, Via Vellichanthai, Near Vellimalai, Kanyakumari District, Tamil Nadu - 629204, India
  • Share us via