Our Products
Features:
FEATURES
Features
FEATURES
Features:
Areas of applications / end-use:-
Electrical insulation for high temperature applications.
Heat resistant covering for bare conductors / ordinary cables.
Fluid delivery systems.
Features:-
Areas of application:
features
TECHNICAL SPECIFICATIONS
GENERAL | Display | STN Blue LCD with CCFL back light |
Display area | 120mm x 90mm | |
Resolution | 320 x 240 pixels | |
Writing speed | 25mm/sec | |
Alarms | Visual (Bell) and Audio (Buzzer beep) | |
Freeze | On demand or automatic on alarm Frozen display on channel 2 | |
Key board | Flat touch membrane operation keys | |
CNS back panel connector | 9 Pin D-sub connector 0.5VjmV at 10mmjmV gain | |
Dimensions | 235 x 166 x 140mm | |
Weight | 1.5 kgs | |
POWER SUPPLY | AC - DC Adapter | 15V DC/1.5A |
AC mains | 100 - 264 V AC | |
Line indicator | Green LED | |
Power consumption | < 18VA | |
Battery | Rechargeable NiMH 9.6V 1400mAh | |
Battery backup duration | 180 minutes (min) | |
Battery low indicator | Red LED | |
ECG display | 4 seconds real time ECG on channel 2 | |
ECG | Leads | User selectable I, II, III |
Lead indicator | Yellow LEDs | |
Heart rate range | 30 - 250 BPM | |
Heat rate accuracy | _+2BPM or 2% whichever is higher | |
Low alarm limit range | 30 to 240 BPM | |
High alarm limit range | 40 to 250 BPM | |
Bandwidth | 0.5 Hz to 35 Hz | |
User gain settings for 10mm display | lmV, 0.66mV, 0.5mV & 2mV display | |
CMRR | > 90dB @ 50Hz | |
Input impedance | > 205M ohms | |
Leakage current | < 20uA | |
Patient isolation | > 2000 V AC @ 50Hz for 1 minute | |
Reset recovery | Automatic return of waveform within 0.5 seconds after defibrillation or electrical overload | |
Defibrillator protected | Yes | |
Patient safety | Class 1 CF | |
ENVIRONMENTAL | Operating temperature | 10° to 40° C |
Relative humidity | 10 to 90% non condensing | |
STANDARD ACCESSORIES | ECG Patient cable | 1 no. |
Disposable electrodes | 30 nos. | |
AC - DC adapter (AD-004) | 1 no. | |
Accessory bag | 1 no. | |
User manual | 1 no. | |
OPTIONAL ACCESSORY | Wall mountable stand | 1 no |
Features
Analog cautery machine 400 watt.
TUR is 400W analog model with number of cut, blend and coagulation mode with to do under water surgery. This is the model with all around capabilities and simple operation. It is lowest cost model in similar class available today in the market.
Important Features SSE - TUR
Patient Plate Return Electrode Monitoring System
Patient Plate Return Electrode Monitoring system provides instant indication of the quality of contact of the patient plate return electrode. Failure or poor contact results in fault indication with sound alarm which substantially reduces the risk of burns under the patient return electrode.
High power efficiency of 97 %
The power effiency of generators are the highest in it's class at 97 %. This leads to multiple benefits like increased reliability, most compact size, high portability, economy and reduced power consumption.
Technical Specification
Max. Power (Watts) | Rated Load (Ohms) | ||
Operating Frequency | 480 Khz | - | |
Pure cut | 400 W | 500 | |
Blend 1 | 250 W | 500 | |
Blend 2 | 200 W | 500 | |
Spray | 120 W | 500 | |
Fulguration | 150 w | 500 | |
Desiccation | 150 W | 500 | |
Bipolar Coagulation | 80 W | 500 | |
Dimension ( W x H x D ) | @4.5 x 10 x 12 | ||
Weight | 3.8 Kg | ||
Input Voltage | 170 to 260 VAC 50 Hz | ||
Here is the list of accessories which will be given with the surgical cautery unit. | |||
Particular | Nos of pcs. | ||
Surgical Monopolar active handle valley lab type. | 1nos | ||
Needle set (electrodes set for above probe) size: - 3/32 |
1nos | ||
Surgical Monopolar active handle fiber made (wooden) | 1nos | ||
Needle set (electrodes set for above probe). size: - 5/32 |
1nos | ||
S.S.patient plate (adult) SIZE: - 12/8 inc | 1nos | ||
Silicon patient plate with 2nos Velcro strap. SIZE: - 11/6 inc |
1nos | ||
patient plate cable cord with 2 jack pi both the side. | 1nos | ||
Hand switch pencil DISPOSABLE. | 2nos | ||
Bipolar forceps STRAIGHT BLUE NYLON COATED | 1nos | ||
Bipolar forceps REGULAR bayonet. | 1nos | ||
Bipolar forceps cable cord. | 1nos | ||
Double paddle foot switch. | 1nos | ||
Monopolar active handle cable cord | 1nos | ||
Single paddle foot switch. | 1nos |
surgical cautery unit 500 watt
Surgical Cautery Unit 400 watt (Digital Model)
Electro surgical cautery unit 400 watt with 99 programs.
high performance cost effective electro surgical generators from girish surgical works.
Important Features
1. Real time tissue response technology:-
real time tissue response technology provides surgeons with superior performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation.
2. Patient plate return electrode monitoring system:-
patient plate return electrode monitoring system provides instant indication of the quality of contact of the patient plate return electrode. Failure or poor contact results in fault indication with sound alarm which substantially reduces the risk of burns under the patient return electrode.
3. High power efficiency of 97 %:-
The power efficency of generators are the highest in it's class at 97 %. This leads to multiple benefits like increased reliability, most compact size, high portability, economy and reduced power consumption.
MULTI PARAMETER PATIENT MONITOR
In-hospital applications include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor delivery and hospital-based special procedure areas.
Technical Specifications
ECG | 2-Temperature· Skin & Intra-Cavity (Optional) |
Input: 5 wires/3 wires ECG cable | Measurement range: 0~500C |
lead selection: I,II,III, aVR, aVl, aVF, V | Accuracy: ± 0.10C |
Gain (mm/mV): 1/4,1/2,1,2,4 & auto | Resolution: 0.10C |
Frequency response: Diagnosis 0.05 - 100Hz | Response time: < 3 min. |
Monitor 0.5 - 35 Hz | Channel: 2 Channel |
Surgery 1.0 - 15 Hz | Respiration Rate (Optional) |
Sweep speed (mm/sec) : 12.5,25,50 | Method: RA-LL Impedance |
Heart rate range: 15-300 BPM | Measurement range: 0 - 120 RPM |
Heart rate accuracy: ± 1 % or ± 1 BPM, which is greater | Accuracy: ± 2 RPM |
ST segment deviation analysis: -2.0 ~ +2.0mV | Resolution: 1 RPM |
ST accuracy: ±0.02mV | Apnea Alarm : 10 ~ 40 Sec. |
Heart Rate Alarm: Yes | Electrical |
Non-Invasive Blood Pressure (Oscillographic) | Input: 100~250 V AC, 50/60Hz |
Measurement type: adult, pediatric, neonate Measurement range: Systolic 40~270mmHg | Consumption: < 110VA |
Diastolic 10~215mmHg | Battery type: Li-ion |
Mean 20~235mmHg | Battery Operation: ~ 3 hrs |
Accuracy: ± 2% or ± 5mmHg, which is greater Resolution: 1 mmHg | Physical |
Protection: over pressure | Weight: ~ 3.5 Kg |
Pulse Oximetry | Size: 210mm x 235mm x 122mm |
SpO2 measurement range: 0 - 100 % | |
Resolution: 1% | |
Pulse measurement range: 0- 254BPM | |
Accuracy: ± 2 %. 70~100% | |
Resolution: 1 BPM |
Features:
TUR is 400W analog model with number of cut, blend and coagulation mode with to do under water surgery. This is the model with all around capabilities and simple operation. It is lowest cost model in similar class available today in the market.
Important Features SSE - TUR
Patient Plate Return Electrode Monitoring System
Patient Plate Return Electrode Monitoring system provides instant indication of the quality of contact of the patient plate return electrode. Failure or poor contact results in fault indication with sound alarm which substantially reduces the risk of burns under the patient return electrode.
High power efficiency of 97 %
Technical Specification
Max. Power (Watts) | Rated Load (Ohms) | ||
Operating Frequency | 480 Khz | - | |
Pure cut | 400 W | 500 | |
Blend 1 | 250 W | 500 | |
Blend 2 | 200 W | 500 | |
Spray | 120 W | 500 | |
Fulguration | 150 w | 500 | |
Desiccation | 150 W | 500 | |
Bipolar Coagulation | 80 W | 500 | |
Dimension ( W x H x D ) | @4.5 x 10 x 12 | ||
Weight | 3.8 Kg | ||
Input Voltage | 170 to 260 VAC 50 Hz | ||
Here is the list of accessories which will be given with the surgical cautery unit. | |||
Particular | Nos of pcs. | ||
Surgical Monopolar active handle valley lab type. | 1nos | ||
Needle set (electrodes set for above probe) size: - 3/32 |
1nos | ||
Surgical Monopolar active handle fiber made (wooden) | 1nos | ||
Needle set (electrodes set for above probe). size: - 5/32 |
1nos | ||
S.S.patient plate (adult) SIZE: - 12/8 inc | 1nos | ||
Silicon patient plate with 2nos Velcro strap. SIZE: - 11/6 inc |
1nos | ||
patient plate cable cord with 2 jack pi both the side. | 1nos | ||
Hand switch pencil DISPOSABLE. | 2nos | ||
Bipolar forceps STRAIGHT BLUE NYLON COATED | 1nos | ||
Bipolar forceps REGULAR bayonet. | 1nos | ||
Bipolar forceps cable cord. | 1nos | ||
Double paddle foot switch. | 1nos | ||
Monopolar active handle cable cord | 1nos | ||
Single paddle foot switch. | 1nos |
Salient features:-
1) 1MMHg controlling (resolution)
2) Single & dual cuff tourniquets are available for all surgeries.
3) Very reliable controlling system is used for perfect pressure.
4) Rugged compressor.
5) User friendly interface.
6) Feathers touch keys.
7) Very bright indicators.
8) Highly stable & compact power supply, hence machine Can be used anywhere, where voltage fluctuations are more.
9) Inbuilt memory to store earlier settings.
10) Air leakage indicator to show air leakage in the cuffs & tubes.
11) Gradual pressure settings & gradual release system.
12) Online increase & decrease of pressure, timer, exhaust.
13) Beep after each 15minuts.
14) After presetted time is complete 1 minute extra time count is provided.
15) On completion of total sited time buzzer beeps continuously but pressure will be maintained at the same level, also it will not be released.
16) Cuff pressure will not be released on power failure.
17) Can be used with inverter power supply & generator.
18) Both hardware & software based exhaust available.
19) We provide 5 numbers of silicon cuffs (life time guarantee on joins) with machine.
20) Light weight machine, easy to carry anywhere.
21) Low power consumption.
22) Can be used for all types of patients (any physical condition)
23) Lowest risk to patient when compared with other machines.
Technical specifications:-
1) Settable pressure range 50mmhg to 650mmhg in steps of 10mmhg.
2) On line setting allows online settings of cuff pressure, timer & exhaust.
3) Pressure resolution 1mmhg.
4) Timer safe mode 1 minute to 6 hours in 15 minutes steps.
5) Alarms beep after each 15 minutes, total time out, exhaust mode, & air leakage mode.Operating modes visual indications:-
A:-air leakage in either cuffs or in the tubes.
O:-operating mode (normal operating)
T:-timer mode.
S:-setting of cuff pressure mode.
E:-exhaust mode. (Software or hardware)