    CHNS+O COMBO ANALYSER

    ₹ 53 Lakh / piece
    Get Latest Price
    • BrandAnalytical Technologies Limited
    • Country of OriginIndia
    • RepeatabilityOxygen, Nitrogen and Carbon : 1ppm or 1%; Hydrogen : 0.2ppm or 2% Sulfur : 1.5%
    • Chemical reagentMagnesium perchlorate, Ascarite
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 11 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 24AAGCA4017N1ZQ

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • BrandAnalytical Technologies Limited
    • Country of OriginIndia
    • Chemical reagentMagnesium perchlorate, Ascarite
    • RepeatabilityOxygen, Nitrogen and Carbon : 1ppm or 1%; Hydrogen : 0.2ppm or 2% Sulfur : 1.5%
    • Analysis timeabout 3 min
    • Carrier gasHigh purity helium for O/N, high purity nitrogen for H Oxygen: purity >99.5%, pressure 0.30 MPa, pressure of furnace end 0.05MPa, 3L/min
    • Electronic balanceWeighing range: 0g-120g. Precision of read: 0.0001g.
    • StructureModular Structure, including analyzer, computer, electronic balance*, printer*, water circulate chillers
    • Pneumatic gasNitrogen or compressed air Pressure imported 0.30 MPa
    • Sample mass1g (Sample mass can be changed according to the content)
    • SensitivityOxygen ,Nitrogen, Hydrogen, Carbon and Sulfur :0.01ppm

    Instrument Principal : 

    CHNS+O Analyzer is a new product, and it is used for oxygen,nitrogen, hydrogen, Carbon, Sulfur determination in ferrous and non-ferrous metals, rare earth materials, alloy, semiconductors, electronic materials, ores, ceramics, coal, graphite, and some organic / inorganic materials.

    • Pulse heating inert gas fusion.
    • O (Oxygen): NDIR(Non Dispersive Infrared absorption);
    • N/H (Nitrogen/Hydrogen): TCD(Thermal Conductivity Detection)
    • Carrier gas (Oxygen) pass through sample extraction unit. Sample combustion at a high temperature, the carbon and sulfur in the sample were converted to CO2 and SO2.and then the mixed gas was measured by infrared detector.
    • The infrared detector using Non-Dispersive-Infrared absorption technology, and it can quickly and accurately measuring carbon & sulfur contents, and it is easy to operate, easy to maintain, easy to repair.

    Instrument Specification : 

    1. Structure : Modular Structure, including electronic balance, computer, printer, high-frequency infrared carbon & sulfur analyzer, tubular resistance furnace, vacuum cleaners, water circulate chillers.

    2. Detection System :

    (i) Solid state Infrared detector is used for Oxygen. Thermo-conductivity detector is used for Nitrogen & Hydrogen.

    (ii) IR Cell: Standard configuration of measure scope is composed of low carbon, high carbon and low sulfur. For specially required scope for sulfur, high sulfur can be added.

    (iii) Detector: Solid-state pyroelectric detector.

    (iv) Motor: Synchronous motor made in Swiss, continuously working.

    (v) IR Emitter: Anti-oxide, stable IR emitter.

    (vi) Temperature control: Keep constant temperature in the whole infrared unit to make sure the temperature of detected gas to be stable and the results to be accurate.

    (vii) Protective gas: Controlled gas flow to purify and protect IR emitters and detectors, avoiding the influence of ambient to improve the stability and accuracy.

    (viii) Thermo-conductivity (TCD) detecting unit: Anti-oxide NTC thermistor (ix) Signal processing: Small current control technique is developed to make sure the thermistors can be used without carrier gas (x) Reference gas circuit: Low flow control technique is used. 

     

    3. Gas flow control: High sensitive and accurate electric flow control technique based on the low pressure difference is applied, and Anti-Overshoot System is applied.

    4. Catalyst unit : a) Catalyst heater: Convert CO to CO2 and SO2 to SO3. b) Filter: SO3 is removed by a filter, to ensure the tail gas reach the requirement of atmospheric environment protection.

    5. Dust filter : Made of powdered metal technique, can be reused by washing in ultrasonic cleaner periodically. Cleaning filter and combustion chamber twice during one analysis by special design of the furnace, which reduce the difficulty of daily maintenance.

    6. Weighing: Sample mass can be transfer from balance into computer automatically, If necessary, the mass can also be manual input.

    7. Analysis time : A typical analysis using induction furnace requires 30-40 seconds.

    8. Crucible Ceramic crucible using in induction furnace is 25mm in diameter.

    9. Furnace: High frequency induction furnace, 18MHz, Max 2.7KVA, (Temperature: Max.3000o C)

    10. Calibration: 1) Fast calibration 2) Normal calibration

    11. Power: 220VAC 10%, 50/60Hz, current max. 50A.

     


    Additional Information

    • Port of DispatchAnalytical House E67/68, Vasna Rd, Ravi Park Society, Saiyed Vasna, Vadodara, Gujarat 390015
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for CHNS+O COMBO ANALYSER?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice