RISH DPM Power 96x96 series measures system active Power(Import Export), Reactive Power (Import Export), Apparent Power &Power Factor of Three phase and Single phase Network. It has 4 digit single line auto ranging LED display with polarity indication. Active Power (kW) DPM, Reactive Power (kVAr) DPM, Apparent Power (kVA) DPM, Power Factor (PF) meter.
The reed type frequency meters, FQ 72 96 housed in mouldedpolycarbonate cases are suitable for the measurement ofThese instruments offer several advantages in switchboard andGenerating Set Panels. Number of meters can be mounted ina single Cut out (Mosaic mounting). Front glass, Bezel & Dial canfrequencies in the range of 45 to 65 Hz.be easily replaced.
RISH Master 3490 DS measures important electrical parameters ofUtility (in normal mode) & Generators (in Power back up) in threephase and single phase Network & replaces the multiple analogpane l meters. It measures electrical parameters like AC current, Voltage, frequency, Active energy import. The instrument hasoptional pulse output as one for Utility and another for Generator.
Three indications are provided, one for each voltage phase. Three illuminated indication indicate active monitoring of each of the three phases. In case if any one phase voltage is missing the appropriate indication will switch OFF .However the meter will continue to accurately measure energy for the available voltage phases. In case of phase sequence error all three indication will start blinking.
The moving coil indicators and a phase angle adjuster are used tomonitor changing power factor conditions on ir-reversible balancedload systems.The power factor is indirectly determined by measuring the phaseangle between current and voltage (both sinusoidal). Howeverthe indicators are calibrated in values of cosine of the angle .These meters offer several advantages in Switchboard &Generating Set panels.Number of meters can be mounted in PanelCut out (Mosaic Mounting).The Bezel, glass and dial can be easilyreplaced.
The N30O meter is destined for the measurement of pulses, frequency, rotational speed, period and worktime. The meter has 2 counter inputs to co-operate with an encoder. The meter counts also the actual and total value.
In case of power failure, the instrument memorizes the last displayed screen. The displayed screen will get memorized only if user keeps this screen for minimum 40 sec duration before power failure for fixed screen mode.In case of power failure, the instrument memorizes the last energy count. Every 40 sec, the instrument updates the energy counter in the non-volatile memory.
N30P meter is destined to measure: AC voltage, AC current, active, reactive and apparent power, cos , tg , , frequency, active, reactive and apparent energy, 15 min. active power, 10 min. voltage, 10 sec. frequency in single-phase power network.
The reed type frequency meters, FQ 72 96 housed in moulded polycarbonate cases are suitable for the measurement of These instruments offer several advantages in switchboard and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). Front glass, Bezel & Dial canfrequencies in the range of 45 to 65 Hz.be easily replaced.
We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
The meter is distinguished by a high measurement accuracy, legible backlit LCD display and an attractive price. Meter is supplied from measurement circuit. The device fulfils the requirements of installation's category III for the product designed.
We are engaged in manufacturing and supplying a wide range of Kilo Watt Meters. These Kilo Watt Meters are manufactured following international industry standards, and assures superb performance. Kilo Watt Meters offered by us are widely.
We are the manufacturer of our porducts. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
The moving coil indicators and a phase angle adjuster are used to monitor changing power factor conditions on ir-reversible balanced load systems.The power factor is indirectly determined by measuring the phase angle between current and voltage (both sinusoidal). However the indicators are calibrated in values of cosine of the angle .
RCT203 is a programmable counter and RPM indicator used to counts events, measures frequency, motor-speed, and cable length as well as measure motor and shaft speeds up to 5000 Hz. For even greater accuracy, RCT203 can be programmed to take in multiple pulse-inputs over 1 rotation and display the correct value via a scaling calculation.
We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters etc.
LCD Touch Screen with user interface panel. Comes with 3 6 programmable input channels. Have 6 12 alarm outputs and 4 8 digital outputs. Visualization of measurements in graphical forms. Compatible with MS windows CE operating System. CE Approved and safety as per European Norms.