The filling & bagging weigh controller system provides 3-relay output for controlling the bag filling & weighing process.
Relay1 – Connected to bag holding clamp actuator.
Relay2 – Connected to coarse filling actuator. This relay operates from zero weight to set-point1 value.
Relay3 – Connected to fine filling actuator. This relay operates from zero weight to setpoint2 value. The input control buttons used in the controller are…
SHIFT key (K3) – Instructs the controller to start the filling process.
TARE key (K4) + Shift key (K3) – To program the set-point1 & set-point2 values in the controller.