Standard parameter: ECG,RESP,NIBP, SPO2, TEMP, PR12.1 large-screen color TFT displayBuilt in high capacity battery, up to 4 hours working tine7- lead ECG waveforms display , big fonts observational interfaceReviewable ECG waveforms, maximum 240 hours reviewing graphic trendsDigital SPO2 technique, precise measurement for weal perfusion and finger shakingArrhythmia and S-T segment analysis and pacemaker detectionProtection against interference from defibrillation and electrosurgical unitApplicable to ICU, CCU, operation, adult, pediatric and neonatal patients
Specification :
ECGFull lead: I, II, III, AVL, AVR, AVF and VGain 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mVScanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/sBand width :0.05Hz-100Hz(3dB)Heart rate:Scope: 15 times/minute to 300 times/minutesAccuracy: ±1 time/minuteVariation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. Arrhythmia :Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.Accuracy: Error rate
SpO2
Detection scope: 0%-100%Accuracy : ±1% 90%-100% ±2% 70%-89%
NIBP
Theory Electric oscillator Cuff gassing time less than 15 secondsFirst-time gassing pressure: dynamic state 24kPa 180 mmHgManual selection: 9.3kPa 70 mmHg13.3kPa 100 mmHg16.0kPa120 mmHg18.6kPa 140 mmHg20.0kPa 150 mmHg21.3kPa 160 mmHgAutomatic detection period: 1 minute to 240 minutesStop size1 min1 min -10min, 5min(10 min -30min), 10min(30 min -90min) and 30min90 min -240minDetection scope: Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)Diastolic pressure: 2kPa -29.3kPa(15mmHg -220mmHg)Mean pressure : 2.7kPa31.3kPa 20mmHg235mmHgDetection accuracy Static pressure: ±3mmHgPulse rate: ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration Scope of chest impedance method 0 time/minute – 100 minutes/minutePrecision of chest impedance method 1 time/minuteDetection scope of carbon oxygen at end of respiration 3mmHg-75mmHg 0.4%vol-9.9%volDetection scope of respiration rate: 2 times/minute ->60 times/minute including babyDetection precision of respiration rate: ±1 time/minute TempSingle/double path Type : Vascular/surface temperatureScope: 20C50CAccuracy : ±0.2 C
Invasive blood pressure (selected mating)
Single/double path Type: direct and continuous detection Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33kPa(100mmHg) above ±2%Frequency responseDC-12HzInput resistance: not less than 500kΩSensitivity of sensor: 5μV/V/mmHgMotivation voltage5V (DC)Accuracy of sensor: ±2Isolation voltage: 4 kV
Invasive blood pressure (selected mating)
Single/double path Type: direct and continuous detection Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33kPa(100mmHg) above ±2%Frequency response:DC-12HzInput resistance: not less than 500kΩSensitivity of sensor: 5μV/V/mmHgMotivation voltage 5V (DC)Accuracy of sensor: ±2Isolation voltage: 4 kV