Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    DWYER USA Sensor: 316 SS Insertion Electromagnetic Flow Sensor, For Conductive Liquids.

    • MaterialBrass Or PVC
    • Brand NameDWYER USA
    • Lining MaterialSensor: 316 SS, Brass Or PVC; Electrodes: Hastelloy®, Metal; Electrode Cap: PVDF; O-ring: EPDM
    • ConditionNew
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Distributor, Importer, Trader, Buying House
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Supplier
    • gst icon GST No. 07AOSPS8386M1ZM

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Brand NameDWYER USA
    • Lining MaterialSensor: 316 SS, Brass Or PVC; Electrodes: Hastelloy®, Metal; Electrode Cap: PVDF; O-ring: EPDM
    • Number Of FlowerSeries EFS2 Insertion Electromagnetic Flow Sensor
    • MaterialBrass Or PVC
    • ApplicationConductive Liquids.
    • ConditionNew
    • Power12 To 25 VDC @ 250 MA; (12 To 25 VDC @ 40 MA (max. 250 MA) - LOP Option).
    • Total Carbohydrate1year

    Insertion Electromagnetic Flow Sensor

    Series EFS2 Insertion Electromagnetic Flow Sensor

    No Moving Parts, Durable, Easy Installation & Maintenance, 1 to 12" Pipe (25 to 305 mm)

    The SERIES EFS2 Insertion Electromagnetic Flow Sensor is designed for pipe sizes from 1 to 12" and comes in three different materials (stainless steel, brass and PVC). There are a variety of custom fittings to choose from to ensure accurate fitting in the pipe. The Series EFS2 is useful for any applications where moving parts would be a problem, such as dirty liquids. It can handle applications where there are rapid changes in viscosity and flow. Other applications include small pipes and chemical metering pumps.

    PRINCIPLE OF OPERATION

    The EFS2 is a liquid flow meter that uses the conductivity of fluids to measure flow rate. Liquid flow through its magnetic field produces a voltage that is measured and translated into an output signal. It has a pulse frequency output which can be used with the Series RTI to indicate flow rate and total, as well as the Series BAT signal converter which provides an analog signal.

    ACCESSORIES

    • Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog output. Unit is loop powered, fits on the enclosure of the meter, and is fields spannable.
    • Series RTI2, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output with local flow rate and totalization display. Unit is loop powered, can fit on the enclosure of the meter, and provides a high/low flow alarm.
    • Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit divides the input frequency to any number from 1 to 9999 with the use of rotary switches to suit a number of metering pump inputs.

    Product Applications

    • Contaminated liquid flow monitoring
    • Flow of conductive liquidsWater & wastewater treatment
    • Industrial systems
    • Irrigation applications
    • Telemetry applications

    Model Description

    • EFS2-1B 1 to 3" Pipe, Brass
    • EFS2-1P 1 to 3" Pipe, PVC
    • EFS2-1S 1 to 3" Pipe, 316 SS
    • EFS2-2B 4 to 10" Pipe, Brass
    • EFS2-2P 4 to 10" Pipe, PVC
    • EFS2-2S 4 to 10" Pipe, 316 SS
    • EFS2-3B 12" Pipe, Brass
    • EFS2-3P 12" Pipe, PVC
    • EFS2-3S 12" Pipe, 316 SS

    Specifications

    • Service:Compatible clean or dirty non-coating, conductive liquids.Range:0.28 to 20 ft/s (0.08 to 6.09 m/s).
    • Wetted Materials:Sensor: 316 SS, brass or PVC;
    • Electrodes: Hastelloy®, metal;
    • Electrode Cap: PVDF;
    • O-ring: EPDM (fluoroelastomer optional).
    • Accuracy:±1% FS.
    • Temperature Limits:Process: Brass/SS: 32 to 200°F (0 to 93°C);
    • PVC: 32 to 130°F (0 to 55°C);
    • Ambient: 0 to 160°F (-17 to 72°C).
    • Pressure Limits:Brass/SS: 200 psi (13.8 bar);
    • PVC: 150 psi (10 bar).
    • Process Connection:See Series EFF.
    • Output:Current sinking, square wave pulse, opto-isolated, 550 Hz @ 20 ft/s.
    • Power Requirements:12 to 25 VDC @ 250 mA; (12 to 25 VDC @ 40 mA (max. 250 mA) - LOP option).
    • Electrical Connection:Terminal block.
    • Conductivity:20 microSiemens/cm.
    • Enclosure Material:Housing: Die-cast powder-coated aluminum.
    • Enclosure Rating:NEMA 4X (IP66).
    • Weight:3 lb (1361 g)


    Additional Information

    • Payment Terms L/C, D/A, D/P, T/T, Western Union
    • Port of DispatchDELHI
    • Delivery Time4-6 WEEK
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • Insertion Electromagnetic Flow Sensor
    • Insertion Electromagnetic Flow Sensor
    • Insertion Electromagnetic Flow Sensor
    • Insertion Electromagnetic Flow Sensor
    • Insertion Electromagnetic Flow Sensor
    • Insertion Electromagnetic Flow Sensor
    • Insertion Electromagnetic Flow Sensor
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Insertion Electromagnetic Flow Sensor?

    Quantity
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice