These Cables are meant for bi-directional communications protocol used for communications among field devices and to the control system. Installed in many process applications such as refining, petrochemicals, power generation, even in food & beverage, pharmaceuticals and nuclear applications.
Voltage Grade | - | 300 V / 600 V |
Conductor | - | Plain/Tinned Annealed Copper (up to 120 Deg. C) Silver Plated Annealed Copper (up to 200 Deg. C) Nickel Plated Annealed Copper (up to 260 Deg. C) |
Range | - | 22 AWG / 18 AWG / 16 AWG / 14 AWG |
Insulation | - | Solid Polyethylene/ XLPE / PFA for temp. >150 Deg. C |
Screening | - | Individual and/or overall with following options - - Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire or - Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper |
Inner Sheath | - | PVC/HR PVC/FR PVC/FRLS PVC/ZHFR/LSF/FEP/PFA |
Armouring | - | Round Galvanized Steel Wire / Flat Strip / Steel Wire Braid |
Outer Sheath | - | PVC/HR PVC/FR PVC/FRLS PVC/ZHFR/LSF/FEP/PFA with Plain Orange Jacket or with strip for easy identification and Blue jacket available for Intrinsically Safe applications |
Standards | - | Cable specification Foundation Fieldbus FF-844 H1, Cable design based on EN 50288-7/BS-5308 Part 1, IEC 60332 Electrical properties: FF-844 H1 and IEC 61158-2, Type A |
Our FF Cable Features | - | Excellent Electrical Charateristics Low Capacitance (for long runs) RoHs compliant and CE marked |
These heavy duty elastomer cables are used in generators, heavy machinery, portable power tools and equipment, moving machinery in wet, hot or oily environments.
Their flexibility permits use in constricted spaces with sharp and complex bends. They can be made with special abrasion resistant sheaths to withstand rough use in portable equipment.
Voltage Grade | - | 450/750 V-AC |
Conductor | - | Bare or tinned flexible class-5 conductors as per IEC-60228/1 |
Range | - | Single Core: up to 300 Sq mm Multi Core: 1 Sq mm - 2.5 Sq mm up to 37 cores 4 Sq mm - 6 Sq mm up to 19 cores 10 Sq mm - 35 Sq mm up to 5 cores |
Insulation | - | EPR |
Sheath | - | Black heavy duty elastomer |
Temperature Range | -25 Deg C to + 85 Deg C | |
Colour Coding | - | 1-5 cores colour coded as Green/Yellow, Blue, Brown, Black, Grey or Coloured Rubberised cotton tapes. 6 cores or more with numbered cores and earth core of Green/Yellow. |
High temperature cables are used in areas where both working temperatures and ambient temperatures are too high. They are made with a wide range of conductors, insulating materials and screening materials depending on the temperatures and conditions under which the cable has to perform.
Construction | - | Single Core or Multi Core / Pairs |
---|---|---|
Voltage Grade | - | 250VAC, 600VAC & 1000VAC (Rating as per MIL 16878, VDE, DIN, ANSI) |
Conductors | - | Annealed bare and/or tinned copper conductor (up to 120° C) Annealed silver plated copper conductor (up to 200° C) Nickel plated conductors (up to 260° C) |
Fire Barrier | - | Glass mica tape |
Insulation | - | Silicone rubber or Cross linked polyolefin elastomer |
Screening | - | Individual and/or overall with following options - - Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire or - Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper |
Innter Sheath | - | LSOH / ZHFR or equivalent |
Armouring | - | Galvanised Steel wire helical armouring or wire braiding |
Outer Sheath | - | LSOH / ZHFR or equivalent |
Standards | - | BS:5308 or equivalent with fire resistance to BS:6387 category CWZ and IEC:60331 tested for 950°C for 3 hrs. |
Insulation | Temperature Range | Characteristics | |
Varnished Fibre Glass Braid |
-72° C to 350° C | High Temperature Resistance | |
FEP | -200° C to 200° C | Good Chemical Resistance Thin wall insulation due to good electrical properties |
|
PFA | -200° C to 250° C | Good Chemical Resistance, Thin wall insulation due to good electrical properties, Good flexibility |
|
PTFE | -200° C to 260° C | Excellent chemical resistance , High temperature stability | |
Kapton tape | -250° C to 300° C | Very thin wall insulation, High temperature resistance | |
PEEK | -160° C to 250° C | Mechanically very tough High temperature and radiation resistance |
|
ETFE | -150° C to 150° C | Mechanically tough | |
Silicone Rubber | -40° C to 200° C | Flexible & abrasion resistance |
Steel | Cables for blast furnace, electric arc furnace, hot & cold rolling mills, steel refining facilities etc. | ||
Communication | High frequency co-axial cables for VHF, UHF and XHF transmission | ||
Marine | Engine proximity wiring for good resistance to high temperatures, fuel oils, chemicals, saline air/water etc. | ||
Petrochemical | Instrumentation & control, temperature sensing, fire warning etc. | ||
Power | In proximity to the turbines, boilers, ash handling etc. |
In addition to these, combinations from the following colours can also be offered -Red, Black, Blue, Brown, Green, Grey, Orange, Violet, White, Yellow.
Alternately, any single colour insulation on all cores with number printing can also be provided.
Constructiion | - | Single core / Multicore |
Voltage Grade | Up to 1100 V | |
Conductor | - | Aluminum / Copper, Solid / Standard / Flexible Conductor |
Range | - | Single core up to 1000 Sq mm Multicore up to 400 Sq mm Max 61 cores of 1.5 Sq mm & 2.5 Sq mm |
Primary Insulation | - | General Purpose PVC / Heat Resistant PVC / LDPE / XLPE |
Inner Sheath | - | PVC / HRPVC / FRPVC / FRLS PVC / ZHFR / LSF |
Armouring | - | GI Round Wire / Flat strip or Wire Braiding |
Outer sheath | - | General purpose PVC / HRPVC / FRLS PVC / ZHFR / LSF |
Standards | - | IS-694, IS-1554 (Part-I), IS-7098 (Part-I) IEC 60502-1 & BS-6346. |
Instrumentation Cables are specially designed to transmit signals without any external interference. They are used in Data Acquisition Systems, connections to Instruments, Computer Networking, PA Systems, Digital / Analog Control / Measuring & Communication Systems.
Construction | - | Cores, pairs, triads or quads |
Voltage Grade | - | Up to 1100 V |
Conductor | - | Electrolytic grade copper Bare / Tinned Solid / Stranded/Flexible conductors |
Range | - | 0.5 / 0.75 / 1.0 / 1.5 / 2.5 Sq mm up to 48 Pair |
Primary Insulation | - | General purpose PVC / Heat Resistant PVC / LDPE / XLPE / PTFE / Fibre Glass / FEP / Silicone Rubber |
Screening | - | Individual and/or overall with following options - - Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire or - Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper |
Inner Sheath | - | PVC / HRPVC / FRPVC / FRLS PVC / ZHFR / LSF |
Armouring | - | GI round Wire / Flat strip or Wire Braiding |
Outer Sheath | - | PVC / HRPVC / FRPVC / FRLS PVC / ZHFR / LSF |
Rip Cord | - | For easy removal of sheath |
Standards | - | BS-5308 Part-1 & 2, BS-7655, IEC-189 (1 & 2), VDE-0815 & 0816 and BS EN 50288 |
Additional Features | - | Communication pairs, Bi-colour extrusion |
Conductor Resistance at 20o C Ohms/Km | Conductor Size mm2 | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 |
Maximum Resistance | 39.0 | 26.0 | 19.5 | 13.3 | 7.98 | |
Capacitance nf/Km | Between conductors | Less than 250 nf/km | ||||
Between conductors & screen | Less than 400 nf/km | |||||
Inductance mH/Km | Less than 1.0 | |||||
L/R Ratio µH/Ohm |
Coductor Size mm2 | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 |
L/R |
<25 | <25 | <25 | <40 | <40 | |
Insulation Resistance at 20o C M ohm-Km | PVC | More than 100 | ||||
LDPE | More than 5000 | |||||
Electostatic noise rejection ratio | More than 76.0 db |
Solar photovoltaic cables are used for transmitting electrical power generated from the solar panel to the charging units, battery banks, change over systems, inverters etc. The cables that are used to carry power from the solar panels to the charging units have to function effectively while remaining exposed to a wide range of severe environmental conditions.
Size (Sq mm) |
Number of Strands/ Diameter |
Nominal Outer dia (mm) |
Max Conductor Resistance Ohms/km |
2.5 | 50/0.25 | 5.50 | 8.21 |
4.0 | 56/0.30 | 6.00 | 5.09 |
6.0 | 85/0.30 | 6.80 | 3.39 |
10.0 | 140/0.30 | 7.70 | 1.95 |
16.0 | 128/0.40 | 8.80 | 1.24 |
Size (Sqmm) |
Single cable in Air (Amps) |
Single cable on surface (Amps) |
Multiple Cable on Surface (Amps) |
2.5 | 41 | 39 | 33 |
4.0 | 55 | 52 | 44 |
6.0 | 70 | 67 | 57 |
10.0 | 98 | 93 | 79 |
16.0 | 132 | 125 | 107 |
Voltage Grade | - | 600/1000 VAC 1000/1800 VDC |
---|---|---|
Ambient Working Temperature | - | -40° C to 90° C |
Maximum Conductor Temperature | - | 120° C Withstands 250° C for 5 seconds |
Standards | - | TUV - 2PfG 1169/07.2008 (Standard for Photovoltaic cables) |
Features | - | Resistant to Oils, Ozone, Water absorption, & severe environmental conditions Working life of more than 25 years |
These cables are used for transmitting power from the generator mounted in the nacelle of the wind tower to base station. These are flexible cables made of special elastomeric compounds, so as to meet the torsional stresses exerted on the cable due to rotation of the nacelle in relation to wind direction.
Control & Instrumentation Cables
These Cables are used in Wind Energy applications such as rotor blade pitch control, Yaw control, Top box, Anemometer feed back, Remote data logging etc. Construction of Cables shall be as per Customers' requirement and conforming to various National/International Standards.
Construction | ||
Voltage Grade | - | 600 V / 1100 V |
Conductor | - | Flexible class-5 tinned or bare copper conductors, made to IEC-60228/IS-8130 |
Range (single core) | - | 10 Sq mm to 300 Sq mm |
Insulation | - | EPR - in conformance to IEC-60502/ IS-6380 |
Sheath | - | Special elastomer compound with Oil, Fire, Hydrolysis and Torsion Resistant properties. (Zero halogen sheath available on request) |
Features | ||
Maximum conductor temperature (continuous) | - | + 90 Deg C |
Short circuit temperature(max) for up to 5 seconds | - | + 250 Deg C |
Maximum permissible tensile load on cable | - | 15 N/mm2 |
Torsion angle | - | ± 100° per meter |
Minimum bending radius | - | 10 D |
Construction - Single or Multiple Pairs Voltage Grade Up to 1100 V Cable Code - Kx, Kx(A), Tx, Jx, Ex, Sx Rx, Bx, Nx, Ux, Wx Range - 16 AWG 18 AWG 20 AWG up to 48 Pair Primary Insulation - General purpose PVC HEAT RESISTANT PVC LDPE XLPE PTFE Fibre Glass FEP Silicone Rubber Screening - Individual andor overall with following options - - Aluminum MylarCopper Tape with Tinned Copper Drain Wire or - Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper
Construction | - | Single or Multiple Pairs |
Voltage Grade | Up to 1100 V | |
Cable Code | - | Kx,Kx(A), Tx,Jx,Ex,Sx / Rx,Bx,Nx,Ux,Wx |
Range | - | 16 AWG / 18 AWG / 20 AWG up to 48 Pair |
Primary Insulation | - | General purpose PVC / HEAT RESISTANT PVC / LDPE / XLPE / PTFE / Fibre Glass / FEP / Silicone Rubber |
Screening | - | Individual and/or overall with following options - - Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire or - Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper |
Inner Sheath | - | PVC / HRPVC / FRPVC / FRLS PVC/ ZHFR / LSF / PTFE / Fibre Glass |
Armouring | - | GI round Wire / Flat strip or Wire Braiding |
Outer sheath | - | PVC / HRPVC / FRPVC / FRLS PVC / ZHFR / LSF / PTFE / Fibre Glass |
Rip cord | For easy removal of sheath | |
Standards | - | ANSI:MC-96.1, IS-8784, DIN, BS & IEC 584-3 |
Finds applications where electrical integrity of the cable has to remain intact for at least three hours, so as toactivate and maintain crucial functions such as fire fighting, public announcements, smoke extraction systems, sprinklers, emergency lighting, evacuation path lighting systems etc.
The areas for Fire resistant cable applications include places where large number of people congregate for short or limited period of time such as shopping malls, cinema theaters, educational institutions, airport terminals, mass transit systems (metro rail networks), high rise office buildings etc. FR cables also find use in power generation facilities, petrochemical complexes, nuclear power facilities, mines etc. for phased shut down of the plant and to keep critical functions like communication, rescue and evacuation systems functional during a fire.
Construction | - | Single Core / Pair / Triad and Multi Cores / Pairs / Traids |
---|---|---|
Voltage Grade | - | 600/1100 VAC |
Conductor | - | Stranded or solid annealed bare or Tinned Copper Conductor |
Fire Barrier | - | Glass mica tape |
Insulation | - | Silicone rubber or Cross linked polyolefin elastomer |
Screening | - | Individual and/or overall with following options - - Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire or - Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper |
Innter Sheath | - | LSOH / ZHFR or equivalent |
Armouring | - | Galvanised Steel wire helical armouring or wire braiding |
Outer Sheath | - | LSOH / ZHFR or equivalent |
Standards | - | BS:5308 or equivalent with fire resistance to BS:6387 category CWZ and IEC:60331 tested for 950°C for 3 hrs. |