Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Water and Soil Analysis Kit

Listing ID #1139975

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate....
View More Details
Send Enquiry

Company Information

  • Member Since 9 Years
  • Nature of Business Retailer
  • Year of Establishment 1993

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate 000 at the start. It is advisable to clean the membrane with a soft tissue paper after every use. Our Water and Soil Analysis Kit is appreciated for its accuracy in measurements and portable size. It is available in an easy-to-use kit.

 

pH Measurements :

  • Put the function switch to pH / Orp mode.
  • Wash the electrode with distilled water and dry it with filter water
  • Connect the electrode BNC plug at the input socket
  • Put the combination pH electrode in buffer solution 7.00 pH.
  • Set the Temp. Knob to the Temp. Of the buffer solution.
  • Now move the switch F2 to pH mode.
  • Read the display value, adjust it with Cal control to 7.00 pH value.
  • Again Move the selector switch F2 to Stand by mode.
  • Take out the electrode from 7.00 pH buffer and wash it with distilled water and dry it with filter paper.
  • Put the electrode in 4.00 pH solution.
  • Set this value to 4.00 pH by setting Slope control.
  • The instruments is ready to take measurements.

 

O.R.P. Measurements :

  • Put the function Switch F1 to pH/ORP mode.
  • Rinse the CRP electrode with distilled water and dry it with filter paper.
  • Connect the ORP electrode BNC plug at Input socket.
  • Take 0.00 mV buffer solution freshly prepared and calibrate with Cal knob.
  • The instruments is calibrated and ready for taking ORP measurement of any other solution.

 

Conductivity Measurements :

  • Put the function switch at Cell Const Position
  • Adjust the display to the cell constant value marked on the conductivity cell supplied with the instrument.
  • Now move the switch to the COND. Position
  • Put the range switch at appropriate positions so that best possible resolution is obtained.

 

TDS Measurements :

  • Put the function switch at TDS Position
  • Clean the conductivity cell, dry it and connect in cond/TDS input socket.
  • Adjust the display to cell constant value marked on conductivity cell by cell const, knob and function switch at Cell const position.
  • Dip the cond. Cell in the unknown solution whose TDS value to be measured.
  • Put the range switch at appropriate PPM/PPT position, so it best possible resolution is obtained.

 

Cell Constant Measurement :

  • It is recommended that cell constant of the conductivity cell must checked off and on. This can be done as follows :
  • Dip the conductivity cell in a solution of known conductivity. (1408µmhos)
  • Keep the function switch Fat Cond position.
  • Adjust the display to the value of known solution by rotating CE Constant Knob.
  • Bring function switch F to Cell const. Position.
  • The display will indicate the cell constant of the conductivity cell.

 

D.O. Measurements is done by following steps :

  • D.O. Probe Assembly
  • D.O. Probe consist of a silver and gold electrode cells, an electrolyte tube with thering.

 

The following procedure may be followed for assembly or D.O. Probe

  • Be careful to handle its membrane. Fit the membrane on the lower part of the electrolyte tube.
  • Fix the ring on the electrolyte tube covering the sides of the membrane.
  • Fill Potassium chloride solution (7.5%) in the electrolyte tube to its top.
  • Insert the electrode in the electrolyte tube and tightly screw it up. Now the probe is ready to use.

 

D.O. Operation :

  • Put the function switch F1 to D.O. Mode and adjust the display to Co.o with Zero knob and insert the D.O. Probe in D.O. Sockets. Please keep colour code in consideration.
  • Keep the Temp knob to the extreme left position and Cal Knob to extreme right position.
  • Place the D.O. Probe in 2% sodium Sulphite solution. Allow the display to attain equilibrium. If the display does not read 000, set the zero knob to bring the display to read 000 by keeping the temp. Knob to actual temp. Of the solution. Calibrate knob should be at extreme right position.
  • Now Calibrate the instrument with known value of D.O. Solution
  • Take 250 ml. Flash and fill 2/3 of it with distilled water.
  • Stopper the flash and shake it for 30 seconds. Remove the stopper back and siri the water back and repeat the procedure 4 times.
  • Measure the temp. Of the water and set the temp. Knob at temp of water in the flask.
  • Hold do probe in the flash and agitate the water. Note the reading of the display and check the value with that of the table below for given temperature. If necessary adjust the meter reading with CaL knob.

 

Note : Please refer to the saturation values of the dissolved Oxygen in distilled water as given in Table 1. it shows the values for dissolved oxygen which will be obtained when shaking the distilled water at different temp. In the air.

Now the instruments is ready to take measurements of D.O. Value of any unknown solution

 

Caution : Since the measurement is based on the diffusion process, the agitation of the solution is must. Hand shaking of the solution may not give accurate readings, magnetic stirrer is recommended for this purpose.

Movement of the solution should be about 2ft/sec for accurate measurement.

BOD bottle is recommended as a container for measurement of sample solution in the laboratory. Because DO probe tight fits in BOD bottle and no atmospheric oxygen may dissolve during measurement.

 

Maintenance of D.O. Probe :

  • Do not touch the silver electrode of the probe.
  • The Membrane must not have any pin hole, puncture. The DO reading will be erratic at constant DO concentration and temperature, if the membrane has a puncture.
  • Any accumulation of organic matter on the membrane will effect the Cal.

It is advisable to clean the membrane with a soft tissue paper after use.


PH Measurements

Range

0 to 14.00 pH

Resolution

0.01 pH

Accuracy

+0.01 pH + 1 digit

Temp. Compensation

0 to 100oC Manual

Slope Correction

80% to 110%

 

Orp Measurements

Range

0 to + 1999 mV

Resolution

1 mV

Accuracy

1% + 1 digit

 

Conductivity Measurements

Range

0-200 m Mhos / Cm in 4 Ranges [0-200µ],

0-2m [0-200µ] 0-2m [0-20000µ], 0-200m [0-200000µ]

Accuracy

+0.5% + 1 digit

Cell constant Adj.

0.5 to 1.5 with digital display

 

TDS Measurements

Range

0 to 200 PPT in 4 ranges [0-200 PPM],

[0-2PPT (0-2000 PPM)]

[0-20PPT (0-20000PPM)],

[0-200PPT (0-200000PPM)

Accuracy

+0.5% + 1 digit

 

Temperature Measurements

Range

0 – 100 oC

Resolution

0.1 oC

Accuracy

+0.2% + 1 digit

 

Dissolved Oxygen

Range

0 to 20 Ppm

Resolution

0.1 Ppm

Accuracy

0.5% + 1 digit

 

General Specifications

Display

3 1/2 digit LCD Display

Decimal positioning

Automatic

Polarity

Automatic

Low Battery

Automatic

Power

230V Ac or 9V, 6 x 1.5 V

 

Dissolved Oxygen Saturation Values Of Distilled Water

Oxygen Solubility (PPM)

OC

Oxygen Solubility (PPM)

14.32

26

8.06

13.92

27

7.9

13.57

28

7.76

13.2

29

7.6

12.88

30

7.5

12.52

31

7.4

12.21

32

7.3

11.91

33

7.2

11.62

34

7.1

11.33

35

7

11.1

36

6.9

10.83

37

6.8

10.61

38

6.7

10.38

39

6.6

10.15

40

6.5

9.95

41

6.4

9.76

 

42

6.3

9.55

43

6.2

9.35

44

6.1

9.16

45

6

9

46

5.9

8.82

47

5.8

8.67

48

5.7

8.41

49

5.6

8.36

50

5.5

8.22

51

5.4

 

Standard Accessories

Combination pH Electrode

1 No.

D.O. Electrode

1 No.

Conductivity Cell (Dip type)

1 No.

Temp. Probe

1 No.

Bottle for pH Solutions

2 No.

Instruction Manual

1 No.

Main Lead

1 No.

Cell container

1 No.

 

Company Details close-icon

1.digital ph meter
2.digital tds meter
3.digital conductivity meter
4.digital soil moisture meter
5.digital seed counter
6.digital electrophorsis power supply
7.digital turbidity meter
8.electrophorsis apparatus
9.digital colorimeter
10.digital auto zero colorimeter
11.digital do meter
12.water analysis kit
13.digital flame photometer
14.digital spectro photometer
15.digital online ph meter
16.digital online tds meter
17..digital online conductivity meter
18.digital online do meter
19.digital conductivity /tds meter
20.microprocessor conductivity meter
21. Microprocessor turbidity meter
22.microprocessor water analysis kit
23.magnetic stirrer
24.karl fischer titrimeter
25. Toshniwal ph meter
26. Toshniwal conductivity meter
27. Toshniwal ph electrode
28.microprocessor ph meter
29. Digital colony counter
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 1993
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Water and Soil Analysis Kit?

Quantity
Seller Contact Details
  • Seller Reena Instruments Co.
  • Address Laxmi Nagar, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Water and Soil Analysis Kit at Best Price in Delhi - ID: 1139975 | Reena Instruments Co.
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Water and Soil Analysis Kit

Listing ID #1139975

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate....
View More Details
Send Enquiry

Company Information

  • Member Since 9 Years
  • Nature of Business Retailer
  • Year of Establishment 1993

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate 000 at the start. It is advisable to clean the membrane with a soft tissue paper after every use. Our Water and Soil Analysis Kit is appreciated for its accuracy in measurements and portable size. It is available in an easy-to-use kit.

 

pH Measurements :

  • Put the function switch to pH / Orp mode.
  • Wash the electrode with distilled water and dry it with filter water
  • Connect the electrode BNC plug at the input socket
  • Put the combination pH electrode in buffer solution 7.00 pH.
  • Set the Temp. Knob to the Temp. Of the buffer solution.
  • Now move the switch F2 to pH mode.
  • Read the display value, adjust it with Cal control to 7.00 pH value.
  • Again Move the selector switch F2 to Stand by mode.
  • Take out the electrode from 7.00 pH buffer and wash it with distilled water and dry it with filter paper.
  • Put the electrode in 4.00 pH solution.
  • Set this value to 4.00 pH by setting Slope control.
  • The instruments is ready to take measurements.

 

O.R.P. Measurements :

  • Put the function Switch F1 to pH/ORP mode.
  • Rinse the CRP electrode with distilled water and dry it with filter paper.
  • Connect the ORP electrode BNC plug at Input socket.
  • Take 0.00 mV buffer solution freshly prepared and calibrate with Cal knob.
  • The instruments is calibrated and ready for taking ORP measurement of any other solution.

 

Conductivity Measurements :

  • Put the function switch at Cell Const Position
  • Adjust the display to the cell constant value marked on the conductivity cell supplied with the instrument.
  • Now move the switch to the COND. Position
  • Put the range switch at appropriate positions so that best possible resolution is obtained.

 

TDS Measurements :

  • Put the function switch at TDS Position
  • Clean the conductivity cell, dry it and connect in cond/TDS input socket.
  • Adjust the display to cell constant value marked on conductivity cell by cell const, knob and function switch at Cell const position.
  • Dip the cond. Cell in the unknown solution whose TDS value to be measured.
  • Put the range switch at appropriate PPM/PPT position, so it best possible resolution is obtained.

 

Cell Constant Measurement :

  • It is recommended that cell constant of the conductivity cell must checked off and on. This can be done as follows :
  • Dip the conductivity cell in a solution of known conductivity. (1408µmhos)
  • Keep the function switch Fat Cond position.
  • Adjust the display to the value of known solution by rotating CE Constant Knob.
  • Bring function switch F to Cell const. Position.
  • The display will indicate the cell constant of the conductivity cell.

 

D.O. Measurements is done by following steps :

  • D.O. Probe Assembly
  • D.O. Probe consist of a silver and gold electrode cells, an electrolyte tube with thering.

 

The following procedure may be followed for assembly or D.O. Probe

  • Be careful to handle its membrane. Fit the membrane on the lower part of the electrolyte tube.
  • Fix the ring on the electrolyte tube covering the sides of the membrane.
  • Fill Potassium chloride solution (7.5%) in the electrolyte tube to its top.
  • Insert the electrode in the electrolyte tube and tightly screw it up. Now the probe is ready to use.

 

D.O. Operation :

  • Put the function switch F1 to D.O. Mode and adjust the display to Co.o with Zero knob and insert the D.O. Probe in D.O. Sockets. Please keep colour code in consideration.
  • Keep the Temp knob to the extreme left position and Cal Knob to extreme right position.
  • Place the D.O. Probe in 2% sodium Sulphite solution. Allow the display to attain equilibrium. If the display does not read 000, set the zero knob to bring the display to read 000 by keeping the temp. Knob to actual temp. Of the solution. Calibrate knob should be at extreme right position.
  • Now Calibrate the instrument with known value of D.O. Solution
  • Take 250 ml. Flash and fill 2/3 of it with distilled water.
  • Stopper the flash and shake it for 30 seconds. Remove the stopper back and siri the water back and repeat the procedure 4 times.
  • Measure the temp. Of the water and set the temp. Knob at temp of water in the flask.
  • Hold do probe in the flash and agitate the water. Note the reading of the display and check the value with that of the table below for given temperature. If necessary adjust the meter reading with CaL knob.

 

Note : Please refer to the saturation values of the dissolved Oxygen in distilled water as given in Table 1. it shows the values for dissolved oxygen which will be obtained when shaking the distilled water at different temp. In the air.

Now the instruments is ready to take measurements of D.O. Value of any unknown solution

 

Caution : Since the measurement is based on the diffusion process, the agitation of the solution is must. Hand shaking of the solution may not give accurate readings, magnetic stirrer is recommended for this purpose.

Movement of the solution should be about 2ft/sec for accurate measurement.

BOD bottle is recommended as a container for measurement of sample solution in the laboratory. Because DO probe tight fits in BOD bottle and no atmospheric oxygen may dissolve during measurement.

 

Maintenance of D.O. Probe :

  • Do not touch the silver electrode of the probe.
  • The Membrane must not have any pin hole, puncture. The DO reading will be erratic at constant DO concentration and temperature, if the membrane has a puncture.
  • Any accumulation of organic matter on the membrane will effect the Cal.

It is advisable to clean the membrane with a soft tissue paper after use.


PH Measurements

Range

0 to 14.00 pH

Resolution

0.01 pH

Accuracy

+0.01 pH + 1 digit

Temp. Compensation

0 to 100oC Manual

Slope Correction

80% to 110%

 

Orp Measurements

Range

0 to + 1999 mV

Resolution

1 mV

Accuracy

1% + 1 digit

 

Conductivity Measurements

Range

0-200 m Mhos / Cm in 4 Ranges [0-200µ],

0-2m [0-200µ] 0-2m [0-20000µ], 0-200m [0-200000µ]

Accuracy

+0.5% + 1 digit

Cell constant Adj.

0.5 to 1.5 with digital display

 

TDS Measurements

Range

0 to 200 PPT in 4 ranges [0-200 PPM],

[0-2PPT (0-2000 PPM)]

[0-20PPT (0-20000PPM)],

[0-200PPT (0-200000PPM)

Accuracy

+0.5% + 1 digit

 

Temperature Measurements

Range

0 – 100 oC

Resolution

0.1 oC

Accuracy

+0.2% + 1 digit

 

Dissolved Oxygen

Range

0 to 20 Ppm

Resolution

0.1 Ppm

Accuracy

0.5% + 1 digit

 

General Specifications

Display

3 1/2 digit LCD Display

Decimal positioning

Automatic

Polarity

Automatic

Low Battery

Automatic

Power

230V Ac or 9V, 6 x 1.5 V

 

Dissolved Oxygen Saturation Values Of Distilled Water

Oxygen Solubility (PPM)

OC

Oxygen Solubility (PPM)

14.32

26

8.06

13.92

27

7.9

13.57

28

7.76

13.2

29

7.6

12.88

30

7.5

12.52

31

7.4

12.21

32

7.3

11.91

33

7.2

11.62

34

7.1

11.33

35

7

11.1

36

6.9

10.83

37

6.8

10.61

38

6.7

10.38

39

6.6

10.15

40

6.5

9.95

41

6.4

9.76

 

42

6.3

9.55

43

6.2

9.35

44

6.1

9.16

45

6

9

46

5.9

8.82

47

5.8

8.67

48

5.7

8.41

49

5.6

8.36

50

5.5

8.22

51

5.4

 

Standard Accessories

Combination pH Electrode

1 No.

D.O. Electrode

1 No.

Conductivity Cell (Dip type)

1 No.

Temp. Probe

1 No.

Bottle for pH Solutions

2 No.

Instruction Manual

1 No.

Main Lead

1 No.

Cell container

1 No.

 

Company Details close-icon

1.digital ph meter
2.digital tds meter
3.digital conductivity meter
4.digital soil moisture meter
5.digital seed counter
6.digital electrophorsis power supply
7.digital turbidity meter
8.electrophorsis apparatus
9.digital colorimeter
10.digital auto zero colorimeter
11.digital do meter
12.water analysis kit
13.digital flame photometer
14.digital spectro photometer
15.digital online ph meter
16.digital online tds meter
17..digital online conductivity meter
18.digital online do meter
19.digital conductivity /tds meter
20.microprocessor conductivity meter
21. Microprocessor turbidity meter
22.microprocessor water analysis kit
23.magnetic stirrer
24.karl fischer titrimeter
25. Toshniwal ph meter
26. Toshniwal conductivity meter
27. Toshniwal ph electrode
28.microprocessor ph meter
29. Digital colony counter
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 1993
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Water and Soil Analysis Kit?

Quantity
Seller Contact Details
  • Seller Reena Instruments Co.
  • Address Laxmi Nagar, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice