S & R Enterprise

S & R Enterprise

Tripura, India

Optical Diffusion Breast Imaging System


Optical Diffusion Breast Imaging System

We work at full throttle to cater for the global market with performance-oriented Optical Diffusion Breast Imaging Systems. We are one of the foremost Importers, Exporters, and Suppliers of Optical Diffusion Breast Imaging Systems from Tripura, India. A well-spread network and skilled manpower instills much confidence in us while taking up the orders. And our ways of dealing with the demand are so orderly that no time is wasted at any point. Rely on us!

 

Four parameters: NIBP, SpO2, Pulse Rate, Temperature :

  • SpO2 waveform, PR strength display
  • 2.8 inch color LCD with real time display
  • Storage/Review trend data up to 3888 groups, data save time interval settable
  • Audio and visual alarm when parameters exceeded and sensor-off
  • Built-in rechargeable Li-ion battery, up to 4 hour running time
  • Automatic shutdown for power saving, shutdown time interval settable
  • Via USB to connect with the computer, unique software for telemonitoring by transmitting data synchronously via internet
  • Battery capacity indicatior and prompt when battery low


Technical Specifications :

  • NIBP :
    • Measure Method : Automatic oscillometric
    • Patient : Adult and Pediatric
    • Measurement unite : mmHg/kPa selectable
    • Measurement mode : Manual, Auto, STAT
    • Measurement Type : SYS, DIA, MAP
    • Measurement interval in AUTO mode : 1,2,3,5,10,15,20,30,45,60Min
    • Measuring period in STAT mode : 5 Min
    • Measure range
    • Adult:30,2550 mmHg; child: 30,160 mmHg
    • Accuracy : 1 mmHg
    • Alarm limits range
    • SYS : Upper limits70,250 mmHg, Lower limits 60,180 mmHg
    • DIA : Upper limits 40,200 mmHg, Lower limits35,150 mmHg
    • MAP : Upper limits 60,230 mmHg, Lower limits 50,160 mmHg
  • SpO2 :
    • Measure Range : 35,100%
    • SpO2 Accuracy : 2%(70,99%), 3%(40,70%)
  • Pulse Rate:
    • Pulse Rate Range : 0254 bpm
    • Pulse Rate Accuracy : 1 bpm
    • SpO2 upper limits : 95,100% lower limits: 85,96%
    • Pulse Rate keep up with the heart rate
  • Temperature :
    • Channel : 1
    • Input: Body surface thermal-sensitive resistor temperature sensor
    • Measurement Unit : oC/oF selectable
    • Measure range : 050oc
    • Alarm limits range : Upper limits 36,45 oc Lower limits 3438oc
    • Measure accuracy : 0.1oc

     

    System specifications :

  • Alarm ON/OFF : controlled by general switch and parameter switch (two levels)
  • Display mode : LED and 2.8’ color LCD screen
  • Trend data : 3888 groups of SpO2, TEMP,SYS, DIA trend data, The record time interval can be set to 5 Sec. to 120 Sec. , so that the record time rang can be up to 128 hr.
  • AC power adaptor
  • Input : AC 100,240V, 50/60Hz, 0.7A
  • Output : DC 5V,2.5A
  • Internal battery
  • Type : 2800mAh/3.7V Li-ion rechargeable battery
  • Operating Time : 6 hours of stand-by time with a full battery
  • Recharge time : 8 hours
  • Dimension : 280mm×190mm×100mm
  • Net Weight : 1000g


  • Weight : 100-500kg
  • Application : Medical Use
  • Type : Optical Imaging System
  • Warranty : 1 Year
  • Color : Available in Many Colors
  • Driven Type : Electric
  • Gross Power : 1-5kw, 10-15kw
  • Voltage : 220V


Looking for Optical Diffusion Breast Imaging System?


Search


Contact Details

Shipan Dhar

Professor Para, College Tilla, Agartala College, Agartala, Tripura - 799004, India

View Mobile No.